article·2015-01-01

Study of monitoring CF3052 /5224 composites molding process by optical fiber Bragg grating

Zhang Jindon

Abstract

Temperature and strain are two of the most important parameters for monitoring the autoclave curing process of composites. The temperature sensor was encapsulated by a steel capillary pipe to shield strain signals.A temperature sensor and a strain sensor were implanted inside the composite simultaneously to monitor the autoclave process in real time so as to obtain internal temperature and strain information. A plate laminate and the triangular region of a T-stiffened panel were monitored. The monitoring results show that the temperature increaseinside the composite was delayed due to the heat transfer. Thus,the pressure applying moment normally determined by the autoclave's temperature may be improper. This phenomenon may cause the defects such as resin starvation. Strain monitoring results show that the strain changes inside the plate laminate can reflect the physical and chemical varieties of the resin during the curing process. In the triangular region of the T-stiffened panel,there is a strain rebound phenomenon during the natural cooling stage,which indicates that the process-induced defects are prone to occur in the triangular region of a T-stiffened panel.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Epoxy Resin Curing Processes · Mechanical Behavior of Composites · Synthesis and properties of polymers

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.