journal article·1989-05-01

Corrosion fatigue of SAE 51100 steel in 3%NaCI solution

Dong Nyung Lee, Sung Keun Lee

Publisher page

Abstract

Fatigue crack propagation rates in SAE 51100 steel tempered at 550°C have been investigated mainly in aerated and deaerated 3%NaCI solutions under sinusoidal, triangular, and square stress waveforms with open circuit and imposed cathodic potentials of −800 and −1100 mV with respect to Ag|AgCl saturated KCI electrode at frequencies of 1 and 10 Hz and in most instances at a stress ratio of 0·1. Most of the fatigue crack growth rates in aqueous solutions may be explained by a major contribution from dissolution and a partial contribution by hydrogen embrittlement, except with the cathodic potential of −1100 mV (Ag|AgCl) in which instance the hydrogen embrittlement is thought to be the major contributor.MST/810
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fatigue and fracture mechanics · Mechanical Failure Analysis and Simulation · Non-Destructive Testing Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. 10.1016/0010-938X(83)90119-110.1016/0010-938X(83)90119-1 ↗
2. 10.1016/0022-5096(74)90010-610.1016/0022-5096(74)90010-6 ↗
3. 1979 · 13 · 38710.1179/msc.1979.13.7.387 ↗
4. 1979 · 13 · 38110.1179/msc.1979.13.7.381 ↗
5. 10.1007/BF0268062010.1007/BF02680620 ↗
6. 1970 · 1 · 3234