Fatigue behavior of 1Cr18Ni9Ti steel at low temperatures and in vacuum
Source abstract
Abstract
Fatigue tests for the 1Cr18Ni9Ti steel were performed under the conditions of the room temperature atmosphere, the room temperature vacuum(300 K,10~(-4)Pa), and the low temperatures vacuum (150,100,(77 K;)10~(-4)Pa), respectively. Microstructures nearby the fatigue fractures of specimens were analyzed by TEM. The effect of environment on fatigue properties was studied. Results showed that the fatigue properties of 1Cr18Ni9Ti steel were remarkably improved under the conditions of vacuum and low temperatures, and there were many lath martensites nearby the fatigue fractures. The reasons for improving the fatigue properties of 1Cr18Ni9Ti steel caused by vacuum and low temperature were attributed to the cleaning-up effect of vacuum on crack surfaces and the formation of lath martensite induced by low temperature.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Microstructure and Mechanical Properties of Steels · Fatigue and fracture mechanics · Metallurgy and Material Forming
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References