Effect of SnO–SiO2 composite coating on bonding of titanium–porcelain
Source abstract
Abstract
The SnO–SiO2 composite coating was deposited on titanium (Ti) by sol–gel dipping process. The adhesion between the Ti and porcelain was evaluated by three point flexure bonding test. The results of thermogravimetry and differential scanning calorimetry analysis showed that the optimal heat treating temperature for SnO–SiO2 composite coating was 300°C. The SEM results revealed that the existence of microcracks on the SnO–SiO2 composite coatings surface after being treated at 300°C. The Ti oxide was formed along the crack. Failure of the Ti–porcelain predominantly occurred at the SnO–SiO2 composite coatings. SnO–SiO2 composite coatings served as an effective oxygen diffusion barrier, improved the chemical bonding between porcelain and Ti and resulted in the increased bonding strength of Ti–porcelain.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Dental materials and restorations · Silicone and Siloxane Chemistry
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Materials Science & Engineering, China University of Mining and Technology, Xuzhou 221116, China
Xi'an Shiyou University, Xi'an 710065, China
The Fourth Military Medical University, Xi'an 710032, China
References (20)
Show source-provided references
1. 10.1016/S0142-9612(00)00263-510.1016/S0142-9612(00)00263-5 ↗
2. 10.1002/jbm.b.2001710.1002/jbm.b.20017 ↗
3. Guo LT · Mater. Lett. · 2008 · 62 · 2204
4. 10.1002/(SICI)1097-4636(199908)46:2<262::AID-JBM16>3.0.CO;2-110.1002/(SICI)1097-4636(199908)46:2<262::AID-JBM16>3.0.CO;2-1 ↗
5. 10.1016/j.surfcoat.2006.07.02310.1016/j.surfcoat.2006.07.023 ↗
6. 10.1177/0022034590069006010110.1177/00220345900690060101 ↗
7. 10.1007/BF0071344810.1007/BF00713448 ↗
8. 10.4012/dmj.26.8410.4012/dmj.26.84 ↗
9. 10.1007/s10853-008-3093-010.1007/s10853-008-3093-0 ↗
10. 10.1002/jbm.1030710.1002/jbm.10307 ↗
11. 10.1016/j.apsusc.2004.05.21910.1016/j.apsusc.2004.05.219 ↗
12. 10.1016/j.dental.2005.01.01410.1016/j.dental.2005.01.014 ↗
13. 10.1007/s10971-008-1807-z10.1007/s10971-008-1807-z ↗
14. ISO 9693, International Organization for Standardization, Geneva, 1999.
15. 10.1016/j.apsusc.2004.09.07510.1016/j.apsusc.2004.09.075 ↗
16. 10.1016/j.vibspec.2007.11.00810.1016/j.vibspec.2007.11.008 ↗
17. 10.1016/j.triboint.2005.08.00410.1016/j.triboint.2005.08.004 ↗
18. 10.1002/(SICI)1097-4636(1999)48:6<778::AID-JBM3>3.0.CO;2-C10.1002/(SICI)1097-4636(1999)48:6<778::AID-JBM3>3.0.CO;2-C ↗
19. 10.2320/materia1962.31.103310.2320/materia1962.31.1033 ↗
20. Yoshimitsu O · Biomaterials · 1998 · 19 · 119710.1016/S0142-9612(97)00235-4 ↗