Residual stress prediction in shot blasted cobalt–chromium biomedical cast components
Source abstract
Abstract
ASTM F75 implants distort due to residual stress released after finishing machining operations, causing implants to fail quality requirements. Previous work has shown that a shot blasting cleaning process could be the source of this distortion. Finite element analysis (FEA) is conducted to predict stress and Almen strip arc heights for experimental comparison. 2D and 3D single impact models and 3D multiple impact models are created. 3D multiple impact models with plastically deforming shot are shown to accurately predict the stress state and distortion. For shot with hardness similar to the implants, distortion creating stress magnitudes are induced, with the greatest fluctuations in stress coming from shot velocity. The depth of the predicted compressive stress layer ranges from 0.23 to 0.6 mm.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Additive Manufacturing Materials and Processes · High-Velocity Impact and Material Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Engineering, University of Limerick, Limerick, Ireland
References (34)
Show source-provided references
1. 10.1080/02670836.2017.128203510.1080/02670836.2017.1282035 ↗
2. Tanner D, Conroy B. Adaptation of the Almen-strip test method to investigate femoral knee implant distortion. 33rd International Manufacturing Conference (IMC33). Limerick: University of Limerick; 2016.
3. 10.1080/02670836.2016.117730410.1080/02670836.2016.1177304 ↗
4. 10.1016/j.joca.2017.07.02210.1016/j.joca.2017.07.022 ↗
5. Baker H · 1992
6. 10.1016/0013-7944(90)90048-L10.1016/0013-7944(90)90048-L ↗
7. 10.1108/0002266991027072710.1108/00022669910270727 ↗
8. ASTM · 2012
9. 10.3390/met911118310.3390/met9111183 ↗
10. 10.1016/j.msea.2006.03.09710.1016/j.msea.2006.03.097 ↗
11. Kirk D. · Shot Peen · 2020 · 34 · 28
12. 10.2991/icectt-15.2015.7210.2991/icectt-15.2015.72 ↗
13. 10.1016/S0045-7949(99)00012-710.1016/S0045-7949(99)00012-7 ↗
14. 10.1179/1743284713Y.000000022210.1179/1743284713Y.0000000222 ↗
15. 10.1016/S0924-0136(00)00893-110.1016/S0924-0136(00)00893-1 ↗
16. Tanner D, Conroy B. Determination of residual stress within ASTM F75 femoral knee implants. BSSM's 11th International Conference on Advances in Experimental Mechanics, Exeter. 2016.
17. 10.1016/S0965-9978(03)00063-210.1016/S0965-9978(03)00063-2 ↗
18. Rouhaud E, Ouakka A, Ould C Finite elements model of shot peening effects of constitutive laws of the material. Proceedings of ICSP-9, Paris, 2005.
19. 10.1016/j.msea.2011.04.01210.1016/j.msea.2011.04.012 ↗
20. 10.1016/S0168-874X(98)00057-210.1016/S0168-874X(98)00057-2 ↗
21. 10.1016/S0734-743X(01)00043-410.1016/S0734-743X(01)00043-4 ↗
22. 10.1016/j.jmatprotec.2005.02.13910.1016/j.jmatprotec.2005.02.139 ↗
23. 10.1016/j.matdes.2008.11.03110.1016/j.matdes.2008.11.031 ↗
24. 10.1016/j.advengsoft.2009.03.01310.1016/j.advengsoft.2009.03.013 ↗
25. 10.1016/j.cja.2016.11.00510.1016/j.cja.2016.11.005 ↗
26. 10.3390/app1001010510.3390/app10010105 ↗
27. 10.1115/1.402800610.1115/1.4028006 ↗
28. 10.1007/s00170-017-0629-y10.1007/s00170-017-0629-y ↗
29. 10.1016/0013-7944(85)90052-910.1016/0013-7944(85)90052-9 ↗
30. Sipei C · Thin-Walled Struct · 2020 · 59 · 107227
31. 10.1016/j.surfcoat.2014.07.07510.1016/j.surfcoat.2014.07.075 ↗
32. 10.1080/02670844.2018.147081710.1080/02670844.2018.1470817 ↗
33. Kirk D. · Shot Peen · 2015 · 29 · 24
34. Brazel E. Power and position-oriented process monitoring of freeform abrasive machining [PhD thesis]. Dublin: Trinity College, Department of Mechanical and Manufacturing Engineering; 2013.