Evaluation of the deterioration of epoxy coating by EIS and WBE techniques
Source abstract
Abstract
To research the failure mechanism of epoxy coating under soaking condition,the deterioration process of epoxy coating immersed in natural seawater was investigated by the wire beam electrode( WBE)and electrochemical impedance spectroscopy(EIS) techniques,and the differences of the current density distribution and EIS characteristics for local regions with defects in the coating were analyzed. The results show that the current density distribution has a close corresponding relationship with EIS characteristics in the whole or local areas,and WBE technique combined with EIS is a powerful tool to investigate the corrosion process of anodic and cathodic regions of the defects and underlying coatings. During the entire coating deterioration process,the EIS characteristics were positively correlated with the substrate corrosion process of the most serious defect,and other regions of the coating and underlying electrochemical processes were suppressed. The polarity transition of the electrode under the coating was observed,and the reasons for the phenomena were different from each other.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Non-Destructive Testing Techniques · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References