journal article·2015-01

Characterisation of materials: Determining density using X-ray microtomography

G. R. Davis, A. N. Z. Evershed, D. Mills

Materials Science and Technology· Volume 31· Issue 2
Publisher page

Abstract

The authors have previously published a method of beam hardening correction for X-ray microtomography that allows accurate determination of mineral concentration in hard tissue. This uses a multi-element calibration carousel for making experimental X-ray attenuation measurements to optimise the parameters in a model of X-ray transmission and detection. From this, a calibration curve is generated to convert the X-ray polychromatic X-ray projection data to that which would be expected with monochromatic X-rays. Furthermore, the calibration curve can be modified according to the known composition of the specimen. Here, this is tested using different materials to assess its accuracy in determining their density. Generally, errors in density of around 1–2 were obtained. When modelling the conventional use of an aluminium step wedge, much larger errors are seen. The technique can be used to measure and map density or concentration in cases where this would be difficult with other methods.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Advanced X-ray Imaging Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dental Physical Sciences, Institute of Dentistry Queen Mary University of London, Mile End Road, London E1 4NS, England

References (20)

Show source-provided references
1. 10.1111/j.1365-2818.1982.tb00376.x10.1111/j.1365-2818.1982.tb00376.x ↗
2. 10.1016/0221-8747(84)90062-610.1016/0221-8747(84)90062-6 ↗
3. 10.1007/BF0279663410.1007/BF02796634 ↗
4. Fearne JM, , Elliott JC, , Wong FSL, , Davis GR, , Boyde A and Jones SJ: Anat. Embryol., 1994, 189, (5), 375–381.10.1007/BF00185432 ↗
5. 10.1007/BF0322064110.1007/BF03220641 ↗
6. 10.1007/BF0029874610.1007/BF00298746 ↗
7. 10.1111/j.1365-2818.2005.01469.x10.1111/j.1365-2818.2005.01469.x ↗
8. 10.1016/S8756-3282(97)00007-010.1016/S8756-3282(97)00007-0 ↗
9. 10.1080/0149573970893669210.1080/01495739708936692 ↗
10. 10.1016/S0168-9002(97)00566-410.1016/S0168-9002(97)00566-4 ↗
11. 10.1088/0031-9155/21/3/00410.1088/0031-9155/21/3/004 ↗
12. Van de Casteele E, , Van Dyck D, , Sijbers J and Raman E: J. X-Ray Sci. Technol., 2004, 12, (1), 43–57.
13. 10.1088/0031-9155/24/1/00810.1088/0031-9155/24/1/008 ↗
14. 10.1109/ICCME.2007.438186910.1109/ICCME.2007.4381869 ↗
15. 10.1007/s00223-008-9158-x10.1007/s00223-008-9158-x ↗
16. Davis G, , Jain N and Elliott J: Develop. X-Ray Tomogr. Vi, 2008, 7078.
17. 10.1118/1.273472610.1118/1.2734726 ↗
18. Berger MJ Hubbell JH Seltzer SM Chang J Coursey JS Sukumar R Zucker DS and Olsen K: XCOM: Photon Cross Section Database (version 1·5) 2013; available from: http://physics.nist.gov/XCOM (viewed 16 December 2013).
19. 10.1016/j.jdent.2013.01.01010.1016/j.jdent.2013.01.010 ↗
20. 10.1117/12.92893310.1117/12.928933 ↗