journal article·2004-05

Quasi-static fracture toughness testing of a single CT specimen at two test conditions

G. Sasikala, S. K. Ray

Materials Science and Technology· Volume 20· Issue 5
Publisher page

Abstract

It is proposed that a single CT specimen can be used for determining J 0.2 at two testing conditions, provided it can be ensured that the crack tip plastic zones for the two tests do not interfere. This is achieved by extending the crack at the end of the first fracture test by fatigue cycling at ambient temperature to obtain the starting crack for the second test. This method has been validated by testing thermally aged CT specimens of modified 9Cr - 1Mo steel at 653 K and 803 K. The J-Δa values obtained by a multispecimen method at a specific temperature were on a single curve irrespective of whether the data were generated from the first test or second test on that sample. Also, the J-Δa curves obtained using a single specimen normalisation method from data on first and second tests were within the expected specimen to specimen variation.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fatigue and fracture mechanics · High Temperature Alloys and Creep · Microstructure and Mechanical Properties of Steels

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (1)

Show source-provided references
1. KUDARI S. K. · Trans. Ind. Inst. Metals · 2003 · 56 · 131