journal article·2020-04

Lowering of elastic modulus in the near-beta Ti–13Nb–13Zr alloy through heat treatment

Pramod Kumar, G. S. Mahobia, V. Singh, Kausik Chattopadhyay

Materials Science and Technology· Volume 36· Issue 6
Publisher page

Abstract

The bio-implant devices require adequate strength and low elastic modulus, for compatibility with human bone. In this study, the near-beta Ti–13Nb–13Zr alloy was subjected to two different solutionising temperatures and quenched at different temperatures. Microstructure modifications and its influence on microhardness, elastic modulus and tensile properties were investigated. Elastic modulus was decreased with increase in cooling rate from solutioning temperature. The samples solutionised at 900°C and quenched at sub-zero temperature contained α ″ martensite along with α′ and β phases and these lowered the elastic modulus. Among all the heat-treated samples, the one solutionised at 900°C and quenched at sub-zero exhibited lowest elastic modulus of 59 GPa and adequate tensile properties for the application as bioimplants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Intermetallics and Advanced Alloy Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Metallurgical Engineering, IIT (BHU), Varanasi, India

References (39)

Show source-provided references
1. 10.1007/s11661-002-0109-210.1007/s11661-002-0109-2 ↗
2. Welsch G, Boyer R, Collings EW. Materials properties handbook: titanium alloys. 2nd ed. ASM International; 1994. p. 1–1176.
3. 10.1016/j.jallcom.2015.02.09510.1016/j.jallcom.2015.02.095 ↗
4. 10.1155/2011/83658710.1155/2011/836587 ↗
5. 10.1007/BF0322074210.1007/BF03220742 ↗
6. 10.1016/j.msea.2003.12.01110.1016/j.msea.2003.12.011 ↗
7. 10.1016/j.stam.2003.09.00210.1016/j.stam.2003.09.002 ↗
8. Mohammed MT, Khan ZA, Siddiquee AN. Beta titanium alloys: the lowest elastic modulus for biomedical applications: a review. Int J Chem 2014; 8:822–827. doi:10.5281/zenodo.1094481.
9. 10.1016/j.vacuum.2017.05.03910.1016/j.vacuum.2017.05.039 ↗
10. 10.1016/j.msec.2010.12.00810.1016/j.msec.2010.12.008 ↗
11. 10.1557/JMR.2001.021010.1557/JMR.2001.0210 ↗
12. 10.1016/j.actbio.2009.06.00210.1016/j.actbio.2009.06.002 ↗
13. 10.4028/www.scientific.net/MSF.539-543.72010.4028/www.scientific.net/MSF.539-543.720 ↗
14. 10.1016/S0142-9612(98)00217-810.1016/S0142-9612(98)00217-8 ↗
15. 10.2320/matertrans.44.238410.2320/matertrans.44.2384 ↗
16. 10.1016/j.msec.2005.04.00310.1016/j.msec.2005.04.003 ↗
17. 10.2320/jinstmet1952.64.11_112010.2320/jinstmet1952.64.11_1120 ↗
18. 10.1016/j.msec.2004.12.00710.1016/j.msec.2004.12.007 ↗
19. 10.1007/978-3-642-56486-4_2010.1007/978-3-642-56486-4_20 ↗
20. 10.1007/s11661-002-0299-710.1007/s11661-002-0299-7 ↗
21. 10.1016/S0921-5093(00)00921-710.1016/S0921-5093(00)00921-7 ↗
22. 10.1007/BF0035644910.1007/BF00356449 ↗
23. 10.1016/j.pnsc.2013.11.00510.1016/j.pnsc.2013.11.005 ↗
24. 10.1016/j.corsci.2018.07.02310.1016/j.corsci.2018.07.023 ↗
25. 10.1016/j.jallcom.2016.09.12310.1016/j.jallcom.2016.09.123 ↗
26. 10.1016/j.jnoncrysol.2008.12.00110.1016/j.jnoncrysol.2008.12.001 ↗
27. 10.1179/09506600322501025410.1179/095066003225010254 ↗
28. 10.1007/BF0284347310.1007/BF02843473 ↗
29. 10.1016/j.jmbbm.2011.03.02310.1016/j.jmbbm.2011.03.023 ↗
30. 10.1016/S0925-8388(01)01604-810.1016/S0925-8388(01)01604-8 ↗
31. 10.1016/S0010-938X(03)00186-010.1016/S0010-938X(03)00186-0 ↗
32. 10.1023/A:100479292215510.1023/A:1004792922155 ↗
33. 10.1016/S0921-5093(00)01891-810.1016/S0921-5093(00)01891-8 ↗
34. 10.1007/s11661-013-2134-810.1007/s11661-013-2134-8 ↗
35. 10.1016/S0142-9612(99)00114-310.1016/S0142-9612(99)00114-3 ↗
36. 10.1016/j.scriptamat.2005.11.00110.1016/j.scriptamat.2005.11.001 ↗
37. 10.1016/j.biomaterials.2004.09.00710.1016/j.biomaterials.2004.09.007 ↗
38. 10.1016/j.msea.2010.04.05710.1016/j.msea.2010.04.057 ↗
39. 10.1016/j.ijfatigue.2004.01.01110.1016/j.ijfatigue.2004.01.011 ↗