journal article·2004-12

New DUV resist characterisation: stability to MB SEMI© F21-95 contaminants

T. Curro, F. Cordiano, G. Franco, G. Mondio, G. Ippedico

Publisher page

Abstract

Abstract Airborne molecular contamination (AMC) effects reveal to be more and more prominent in clean room manufacturing areas, shrinking the dimensions of electronic circuits such as the last generation of flash memory devices (0.15–0.13 μm). This work enabled us to evaluate new resist stability to specific airborne contamination class in critical conditions; that is basic contamination of clean room environments (∼20 ppb), higher than a typical contamination status inside Deep UV equipment chambers (∼2 ppb). Formation of the so-called T-Topping (see Fig. 1) was observed, qualitatively discussed and quantitatively measured, facilitating comparison between experimental data on a time scale basis and a theoretical model developed for interpret contaminants adsorption on ultra clean surfaces; then we interpolated critical data between 1 and 5 min to gather information on process material characterization. The starting adsorption shift rate revealed to be 12 nm/min, showing that T-Topping is an almost instantaneous phenomena and that 2 min are sufficient to obtain CD values higher than specification limits in the experimental conditions. Finally, we calculated the resist characterization parameter (max shift rate per ppbV of airborne basis concentration) on a pure theoretical basis (0.637 nm/min/ppbV) resulting in a very good agreement with literature [D. Kinkead, W. Goodwin, K., MICRO 18(9) (2000) 71–84].
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advancements in Photolithography Techniques · Industrial Vision Systems and Defect Detection · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Sheng-Bai Zhu, Molecular contamination on silicon wafers: a Theoretical study, Asyst Technologies Inc., 48761 Kato Road Fremont, CA 94538.
2. SEMI® F21-95, Classification of airborne molecular contaminant levels in clean environments, Semiconductor Equipment and Material International (SEMI®), 3081 Zanker Road, San Jose, CA 95134.
3. International Business Machines Corp.
4. Prutton · 1994
5. Woodruff · 1989
6. P. Silvestroni, Facoltà d’Ingegneria, Università di Roma La Sapienza, Fondamenti di chimica, Masson S.p.a., 1992.
7. D. Kinkead, M. Joffe, J. Higley, O. Kishkovich, Forecast of airborne molecular contamination limits for the 0.25μm high performance logic process, Technology transfer #95052812A-TR, SEMATECH, 31 May 1995.
8. K.D. Oleg Kishkovich, Environmental stability of chemically amplified resists: proposing an industry standard methodology for testing, International SEMATECH, Austin, TX Extraction Systems Inc., Franklin, MA.
9. Y. Kawai, The Effects of an Organic Base in a Chemically Amplified Resist on Patterning Characteristics Using KrF Lithography, Digest of Papers, MicroProcess’94, The 7th MicroProcess Conference, 1994, pp. 202–203.10.1143/JJAP.33.7023 ↗
10. Ito · 1996
11. Hayward · 1964
12. Kinkead · MICRO · 2000 · 18 · 71