Corrosion study of anisotropic conductive joints on polyimide flexible circuits

C.W. Tan, Y.W. Chiu, Y.C. Chan

Publisher page

Abstract

Abstract In application, ACF joints often undergo thermal foray and since under most circumstances moisture absorption exists at the same time, the combined effects are, therefore, important. Autoclave test was used in this study as a stimulator for stress-corrosion cracking in the strong presence of hygroscopic swelling-induced stress. SEM/EDX analysis showed evidences of metal oxidation and stress-corrosion cracking at ACF joints. Apart from the physical damages, results of FTIR spectroscopy showed chemical modification to aged ACF joints under the effect of autoclave test condition. ACF joints lost their epoxy functionality after 288 h and hydrolysis was becoming obvious after 384 h of the autoclave test.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Liu · 1999 · 212
2. Yeh · IEEE Trans. Component Packaging Manufact. Technol. Part A · 1997 · 20 · 47010.1109/95.650937 ↗
3. Palm · Microelectr. Reliab. · 2001 · 41 · 63310.1016/S0026-2714(01)00009-9 ↗
4. R.D. Burg, J.H. Constable, J.J. Decker, J.W. Weidler, Electrical characteristics of an ACF bond as a function of temperature and humidity aging. Proceedings of IEEE Electronic Component and Technology Conference, 2000, pp. 906–913.
5. Liu · Int. J. Adhesion Adhesives · 1996 · 16 · 28510.1016/S0143-7496(96)00016-4 ↗
6. E.H. Wong, K.C. Chan, R. Rajoo, T.B. Lim, The mechanics and impact of hygroscopic swelling of polymeric materials in electronic packaging. Proceedings of IEEE Electronic Component and Technology Conference, 2000, pp. 576–580.10.1109/ECTC.2000.853216 ↗
7. Ellis · 1993
8. Park · Polymer · 1997 · 38 · 381110.1016/S0032-3861(96)00972-X ↗
9. B. Gao, J. Unsworth, Y. Li, Degradation of epoxy insulation under combined high humidity and elevated temperature. Proceedings of the Fourth IEEE International Conference on Properties and Applications of Dielectric Materials, 1994, pp. 752–755.
10. Sun · Microelectr. Reliab. · 2001 · 32 · 19710.1016/S0026-2692(00)00153-1 ↗
11. Fraga · J. Appl. Polym. Sci. · 2001 · 82 · 336610.1002/app.2195 ↗
12. Silverstein · 1998
13. Effect of autoclave test on anisotropic conductive joints10.1016/S0026-2714(02)00293-7 ↗
14. Behaviour of anisotropic conductive joints under mechanical loading’10.1016/S0026-2714(02)00318-9 ↗