Abstract

In this study, poly(Eriochrome Black T) /copper oxide nanocomposites were simultaneously electrodeposited on a graphenized pencil electrode (GPE/PEBT/CuO) for sensitive determination of Cd 2+ and Pb 2+ in water samples. Active surface area of the prepared electrode was remarkably increased in comparison with GPE/Cu and GPE/PEBT. Under the optimized conditions including accumulation time of 200 s, accumulation voltage of −1.0 V and pH 6, the prepared GPE/PEBT/CuO was utilized for Cd 2+ and Pb 2+ determination by differential pulse anodic stripping voltammetry with good linearity in the concentration range of 7.8–78 µg/L and 22–220 µg/L, detection limit of 1.8 µg/L and 6.85 µg/L and sensitivity of 0.1081 µA µg −1 L and 0.0394 µA µg −1 L respectively. The method was properly utilized for Cd 2+ and Pb 2+ detection in tap and river water samples with satisfactory results.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical Analysis and Applications · Electrochemical sensors and biosensors · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Recent advances in miniaturized electrochemical analyzers for hazardous heavy metal sensing in environmental samples10.1016/j.ccr.2023.215487 ↗
2. Biomass derived worm-like nitrogen-doped-carbon framework for trace determination of toxic heavy metal lead (II)10.1016/j.aca.2020.04.033 ↗
3. Application of magnetic ion-imprinted polymer as a new environmentally-friendly nonocomposite for a selective adsorption of the trace level of Cu (II) from aqueous solution and different samples10.1016/j.molliq.2017.08.018 ↗
4. Heavy metal poisoning: the effects of cadmium on the kidney10.1007/s10534-010-9328-y ↗
5. A novel design of engineered multi-walled carbon nanotubes material and its improved performance in simultaneous detection of Cd (II) and Pb (II) by square wave anodic stripping voltammetry10.1016/j.snb.2016.05.149 ↗
6. Emerging Trends in nanostructured materials-coated screen printed electrodes for the electrochemical detection of hazardous heavy metals in environmental matrices10.1016/j.chemosphere.2023.140231 ↗
7. A review of the identification and detection of heavy metal ions in the environment by voltammetry10.1016/j.talanta.2017.08.033 ↗
8. Double-shelled yolk-shell Si@ C microspheres based electrochemical sensor for determination of cadmium and lead ions10.1016/j.aca.2019.06.011 ↗
9. Electrodes modified with 3D graphene composites: a review on methods for preparation, properties and sensing applications10.1007/s00604-018-2809-3 ↗
10. Recent advances in the modification of electrodes for trace metal analysis: a review10.1039/D3AN01252B ↗
11. Perspective and application of modified electrode material technology in electrochemical voltammetric sensors for analysis and detection of illicit drugs10.1016/j.sna.2021.112821 ↗
12. Controlled Electrodeposition of Au-Copper Oxide Nanocomposite on a Renewable Carbon Ceramic Electrode for Sensitive Determination of NADH in Serum Samples10.1002/elan.201900592 ↗
13. Copper oxide anchored polyaniline modified glassy carbon electrode: A new sensor platform for the Amperometric determination of Chlorpyrifos10.1016/j.electacta.2023.143305 ↗
14. Y. Lu, X. Hu, L. Tang, B. Peng, J. Tang, T. Zeng, XunkuoZhang, Q. Liu, Effect of CuO/ZnO/FTO electrode properties on the performance of a photo-microbial fuel cell sensor for the detection of heavy metals, Chemosphere 302 (2022) 134779.10.1016/j.chemosphere.2022.134779 ↗
15. A polyrutin/AgNPs coated GCE for simultaneous anodic stripping voltammetric determination of Pb (II) and Cd (II) ions in environmental samples10.1016/j.colsurfa.2022.129082 ↗
16. Electrochemical reduced graphene oxide-poly (eriochrome black T)/gold nanoparticles modified glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid10.1016/j.arabjc.2018.09.002 ↗
17. N. Mohammed Modawe Alshik Edris, J. Abdullah, S. Kamaruzaman, Y. Sulaiman, Voltammetric determination of hydroquinone, catechol, and resorcinol by using a glassy carbon electrode modified with electrochemically reduced graphene oxide-poly (Eriochrome black T) and gold nanoparticles, Microchim. Acta 186 (2019) 1-9.10.1007/s00604-019-3376-y ↗
18. Synthesis challenges for graphene industry10.1038/s41563-019-0341-4 ↗
19. Graphene synthesis, characterization and its applications: A review10.1016/j.rechem.2021.100163 ↗
20. Graphene synthesis10.1016/j.diamond.2014.04.006 ↗
21. How to get between the sheets: a review of recent works on the electrochemical exfoliation of graphene materials from bulk graphite10.1039/C4NR06942K ↗
22. Electrolyte effect in electrochemical exfoliation of graphite10.1016/j.matchemphys.2023.127713 ↗
23. Electrochemical Exfoliation of Graphene Oxide: Unveiling Structural Properties and Electrochemical Performance10.1002/chem.202302450 ↗
24. Controlled electrochemical surface exfoliation of graphite pencil electrodes for high-performance supercapacitors10.1039/D3RA03952H ↗
25. Electrochemical exfoliation of 2D materials beyond graphene10.1039/D3CS00815K ↗
26. Manganese oxide nanoparticles electrodeposited on graphenized pencil lead electrode as a sensitive miniaturized pH sensor10.1007/s10854-018-0471-5 ↗
27. Amperometric sensor for dopamine based on surface-graphenization pencil graphite electrode prepared by in-situ electrochemical delamination10.1007/s00604-019-3430-9 ↗
28. Electrodeposition of Ag nanoparticles on graphenized pencil lead electrode as a sensitive and low-cost sensor for iodate determination10.1007/s13738-018-1436-6 ↗
29. Preparation and Characterization of Graphenized Pencil Lead Electrode for Sensitive Determination of Bisphenol A in Canned Food and Plastic Bottled Drinking Water Samples10.1166/sl.2017.3859 ↗
30. An electrochemical sensor based on an Eriochrome Black T polymer and deep eutectic solvent for the simultaneous determination of omeprazole and lansoprazole10.1039/D0AY01078B ↗
31. Application of a thin film of poly(solochrome black T) as a redox mediator for the electro-catalytic simultaneous determination of dopamine and acetaminophen in the pharmaceutical and biological samples10.1016/j.msec.2015.08.044 ↗
32. Low cost, sensitive and selective chronoamperometric determination of vanillin at a disposable poly (eriochrome black t)/pencil graphite electrode10.24323/akademik-gida.729976 ↗
33. A.G. Al-Harazie, E.A. Gomaa, R.R. Zaky, M.N. Abd El-Hady, Spectroscopic Characterization, Cyclic Voltammetry, Biological Investigations, MOE, and Gaussian Calculations of VO (II), Cu (II), and Cd (II) Heteroleptic Complexes, ACS omega 8(15) (2023) 13605-13625.10.1021/acsomega.2c07592 ↗
34. Fabrication of cuprous and cupric oxide thin films by heat treatment10.1016/j.apsusc.2009.07.072 ↗
35. Simultaneous Electrodeposition of Reduced Graphene Quantum Dots/Copper Oxide Nanocomposite on the Surface of Carbon Ceramic Electrode for the Electroanalysis of Adenine and Guanine10.1002/elan.202100256 ↗
36. M. Mulvihill, A. Tao, K. Benjauthrit, J. Arnold, P. Yang, Surface-Enhanced Raman Spectroscopy for Trace Arsenic Detection in Contaminated Water, Angew. Chem., Int. Ed. 47(34) (2008) 6456-6460.10.1002/anie.200800776 ↗
37. Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples10.1016/j.aca.2008.06.010 ↗
38. Synthesis of Bismuth-Nanoparticle-Enriched Nanoporous Carbon on Graphene for Efficient Electrochemical Analysis of Heavy-Metal Ions10.1002/chem.201500512 ↗
39. Ultrasensitive and Simultaneous Electrochemical Determination of Pb2+ and Cd2+ Based on Biomass Derived Lotus Root-Like Hierarchical Porous Carbon/Bismuth Composite10.1149/1945-7111/ab82f7 ↗
40. Simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry at a gold nanoparticle-graphene-cysteine composite modified bismuth film electrode10.1016/j.electacta.2013.10.209 ↗
41. Penicillamine-modified sensor for the voltammetric determination of Cd(II) and Pb(II) ions in natural samples10.1016/j.talanta.2015.06.083 ↗
42. Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode