Multiple-step graphene grating optical sensors based on surface plasmons in IR range for ultra-sensing biomolecules
Source abstract
Abstract
Abstract The emergent need for high-sensitivity and low-cost sensors to detect biomolecules and diseases in the shortest time is one of the important targets in medical and industrial progress. In this paper, multiple-step sensors based on SPR in graphene were proposed and investigated. The structures consisted of graphene-gold gratings that were separated into three different sensors: single, double and triple-step. The sensitivity and quality factor of these sensors were calculated, and their response in the infrared region was investigated. The best quality factor of the double-step sensor was 15,583 for the refractive index of 1.300 and it was 42,944 for triple-step in the refractive index of 1.200, which is a great performance. It was found that the double-step sensor can measure the refractive index of substances--A_G protein and guanine--with an accuracy of 0.00005; while that of the triple step sensor can detect materials--water, glucose, and blood--in order of 0.00001.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Plasmonic and Surface Plasmon Research · Photonic and Optical Devices · Optical Coatings and Gratings
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. V. Nanduri et al., SPR biosensor for the detection of L. monocytogenes using phage-displayed antibody. 2007. 23(2): p. 248-252.10.1016/j.bios.2007.04.007 ↗
2. J. Chung et al., Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV). 2005. 111: p. 416-422.10.1016/j.snb.2005.03.055 ↗
3. Soler, M., C.S. Huertas, and L.M.J.E.r.o.m.d. Lechuga, Label-free plasmonic biosensors for point-of-care diagnostics: a review. 2019. 19(1): p. 71-81.10.1080/14737159.2019.1554435 ↗
4. N. Mudgal et al., Comparative Study of Interferometer and Ring Resonator Based Biosensors: A Review, in Optical and Wireless Technologies. 2020, Springer. p. 419-427.10.1007/978-981-13-6159-3_44 ↗
5. Homola, J.J.A. and b. chemistry, Present and future of surface plasmon resonance biosensors. 2003. 377(3): p. 528-539.10.1007/s00216-003-2101-0 ↗
6. Grattan, K.T. and B. Meggitt, Optical fiber sensor technology. Vol. 1. 1995: Springer.10.1007/978-94-011-1210-9 ↗
7. G. Mason A. Al-Ali T.J. Gerhardt, Flex circuit shielded optical sensor. 2006, Google Patents.
8. K.M. Mayer et al., A label-free immunoassay based upon localized surface plasmon resonance of gold nanorods. 2008. 2(4): p. 687-692.10.1021/nn7003734 ↗
9. Y. Chen and H.J.P.S. Ming, Review of surface plasmon resonance and localized surface plasmon resonance sensor. 2012. 2(1): p. 37-49.10.1007/s13320-011-0051-2 ↗
10. J. Homola et al., Surface plasmon resonance sensors. 1999. 54(1-2): p. 3-15.10.1016/S0925-4005(98)00321-9 ↗
11. A. Hohenau et al., Dielectric optical elements for surface plasmons. 2005. 30(8): p. 893-895.10.1364/OL.30.000893 ↗
12. Rigon, M., E.D. Gaspera, and A.J.M.D.P.I.P. Martucci, Optical Gas Sensors Based on Localised Surface Plasmon Resonance. 2019. 14(1): p. 19.10.3390/proceedings2019014019 ↗
13. D. Zhang et al., Nanoplasmonic biosensor: coupling electrochemistry to localized surface plasmon resonance spectroscopy on nanocup arrays. 2015. 67: p. 237-242.10.1016/j.bios.2014.08.022 ↗
14. A. Vinogradov et al., Exciting surface plasmon polaritons in the Kretschmann configuration by a light beam. 2018. 97(23): p. 235407.10.1103/PhysRevB.97.235407 ↗
15. B. Liedberg et al., Surface plasmon resonance for gas detection and biosensing. 1983. 4: p. 299-304.10.1016/0250-6874(83)85036-7 ↗
16. Gwon, H.R. and S.H.J.M.t. Lee, Spectral and angular responses of surface plasmon resonance based on the Kretschmann prism configuration. 2010. 51(6): p. 1150-1155.10.2320/matertrans.M2010003 ↗
17. D. Cai et al., Improving the sensitivity of SPR sensors based on gratings by double-dips method (DDM). 2008. 16(19): p. 14597-14602.10.1364/OE.16.014597 ↗
18. K. Lin et al., Surface plasmon resonance hydrogen sensor based on metallic grating with high sensitivity. 2008. 16(23): p. 18599-18604.10.1364/OE.16.018599 ↗
19. J. Homola et al., Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison. 1999. 54(1-2): p. 16-24.10.1016/S0925-4005(98)00322-0 ↗
20. Y. Li et al., Graphene plasmon enhanced vibrational sensing of surface-adsorbed layers. 2014. 14(3): p. 1573-1577.10.1021/nl404824w ↗
21. W. Wei et al., Coupling of graphene plasmonics modes induced by near-field perturbation at terahertz frequencies. 2016. 11(4): p. 1109-1118.10.1007/s11468-015-0149-2 ↗
22. K.S. Novoselov et al., A roadmap for graphene. 2012. 490(7419): p. 192.10.1038/nature11458 ↗
23. K.S. Novoselov et al., Two-dimensional gas of massless Dirac fermions in graphene. 2005. 438(7065): p. 197.10.1038/nature04233 ↗
24. L. Ju et al., Graphene plasmonics for tunable terahertz metamaterials. 2011. 6(10): p. 630.10.1038/nnano.2011.146 ↗
25. L. Wu et al., Highly sensitive graphene biosensors based on surface plasmon resonance. 2010. 18(14): p. 14395-14400.10.1364/OE.18.014395 ↗
26. A. Patnaik K. Senthilnathan R.J.I.P.T.L. Jha, Graphene-based conducting metal oxide coated D-shaped optical fiber SPR sensor. 2015. 27(23): p. 2437-2440.10.1109/LPT.2015.2467189 ↗
27. R.M. de Oliveira et al., FDTD formulation for graphene modeling based on piecewise linear recursive convolution and thin material sheets techniques. 2014. 14: p. 767-770.10.1109/LAWP.2014.2378174 ↗
28. H.S. Skulason, Optical properties of few and many layer graphene flakes. 2009, McGill University.
29. Z. Sadeghi and H.J.P. Shirkani, High-Performance Label-Free Near-Infrared SPR Sensor for Wide Range of Gases and Biomolecules Based on Graphene-Gold Grating. 2019: p. 1-10.10.1007/s11468-019-00906-z ↗
30. M. Hernaez et al., Optical fibre sensors using graphene-based materials: A review. 2017. 17(1): p. 155.10.3390/s17010155 ↗
31. Hale, G.M. and M.R.J.A.o. Querry, Optical constants of water in the 200-nm to 200-μm wavelength region. 1973. 12(3): p. 555-563.10.1364/AO.12.000555 ↗
32. K.A. Willets R.P.J.A.R.P.C. Van Duyne, Localized surface plasmon resonance spectroscopy and sensing. 2007. 58: p. 267-297.10.1146/annurev.physchem.58.032806.104607 ↗
33. Rowe, D.J., D. Smith, and J.S.J.S.r. Wilkinson, Complex refractive index spectra of whole blood and aqueous solutions of anticoagulants, analgesics and buffers in the mid-infrared. 2017. 7(1): p. 7356.10.1038/s41598-017-07842-0 ↗
34. D. Rodrigo et al., Mid-infrared plasmonic biosensing with graphene. 2015. 349(6244): p. 165-168.10.1126/science.aab2051 ↗
35. Lirtsman, V., M. Golosovsky, and D.J.J.o.A.P. Davidov, Infrared surface plasmon resonance technique for biological studies. 2008. 103(1): p. 014702.10.1063/1.2828162 ↗
36. K. Hinrichs et al., Ellipsometry from infrared to vacuum ultraviolet: Structural properties of thin anisotropic guanine films on silicon. 2005. 242(13): p. 2681-2687.10.1002/pssb.200541154 ↗
37. M. Al Mahfuz et al., Asymmetrical photonic crystal fiber based plasmonic sensor using the lower birefringence peak method. 2019. 2(5): p. 1713-1725.10.1364/OSAC.2.001713 ↗
38. C. Caucheteur V. Voisin J.J.O.E. Albert, Near-infrared grating-assisted SPR optical fiber sensors: design rules for ultimate refractometric sensitivity. 2015. 23(3): p. 2918-2932.10.1364/OE.23.002918 ↗
39. J.N. Dash and R.J.P. Jha, Highly sensitive side-polished birefringent PCF-based SPR sensor in near IR. 2016. 11(6): p. 1505-1509.10.1007/s11468-016-0203-8 ↗
40. Y. Dai et al., Experimental demonstration of high sensitivity for silver rectangular grating-coupled surface plasmon resonance (SPR) sensing. 2018. 416: p. 66-70.10.1016/j.optcom.2018.02.010 ↗
41. L. Wu et al., High-Performance Lossy-Mode Resonance Sensor Based on Few-Layer Black Phosphorus. 2018. 122(13): p. 7368-7373.10.1021/acs.jpcc.7b12549 ↗
42. J. Tang et al., High-Sensitivity Terahertz Refractive Index Sensor in a Multilayered Structure with Graphene. 2020. 10(3): p. 500.10.3390/nano10030500 ↗
43. S. Singh and Y.J.A.P.A. Prajapati, Highly sensitive refractive index sensor based on D-shaped PCF with gold-graphene layers on the polished surface. 2019. 125(6): p. 437.10.1007/s00339-019-2731-5 ↗
44. J. Yang et al., Beam steering and deflecting device using step-based micro-blazed grating. 2008. 281(15-16): p. 3969-3976.10.1016/j.optcom.2008.04.032 ↗