Reconstruction and quantitative characterization of the three dimensional microstructure model of TC6 titanium alloy based on dual-energy X-ray microtomography
Source abstract
Abstract
Abstract In the present study, dual-energy micro-computed tomography (Micro-CT) imaging was employed to overcome the difficulty of low absorption contrast due to the low difference in density among the primary α phase, secondary α phase, and β phase of the annealed microstructure (annealing at 800 °C for 2 h followed by air cooling) of TC6 titanium alloy. The three dimensional microstructure model of TC6 titanium alloy was first achieved by laboratory X-ray microtomography, and then analyzed quantitatively. It is found that the volume fractions of the primary α phase, secondary α phase and β phase are 28.32%, 47.78% and 23.90%, respectively. Some complex microstructural features of TC6 titanium alloy such as spatial distribution, shapes, and interconnectivities that can hardly be described by the conventional two dimensional microscopy technique were successfully captured. In three dimensional space, the primary α phase is composed of discrete equiaxed grains and interconnected grains, and the fraction of the individual equiaxed grains is up to 50% and the average diameter is about 10 µm; the secondary α phase interconnects with β phase forming a completely interconnected network.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Advanced X-ray Imaging Techniques · Additive Manufacturing Materials and Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Microstructure design and mechanical properties in a near-α Ti–4Mo alloy10.1016/j.actamat.2015.06.043 ↗
2. The effect of microstructure on the mechanical properties of two-phase titanium alloys10.1016/S0924-0136(02)00248-0 ↗
3. The effect of microstructure on the mechanical properties of two-phase titanium alloys10.1016/S0261-3069(97)00087-3 ↗
4. Quantitative metallography of two-phase titanium alloys10.1016/S1044-5803(01)00117-6 ↗
5. Three-dimensional analysis of microstructures10.1016/S1044-5803(00)00046-2 ↗
6. Three-dimensional characterization of pores in Ti-6Al-4V alloy10.1590/S1516-14392011005000014 ↗
7. Automated serial sectioning for 3-D analysis of microstructures10.1016/j.scriptamat.2006.01.019 ↗
8. Reconstruction and quantitative characterization of multiphase, multiscale three-dimensional microstructure of a cast Al-Si base alloy10.1007/s11663-009-9291-6 ↗
9. Three-dimensional microtomographic study of Widmanstätten microstructures in an alpha/beta titanium alloy10.1016/j.scriptamat.2007.11.005 ↗
10. High resolution cone beam x-ray computed tomography of 3D-microstructures of cast Al-alloys10.1016/j.matchar.2010.11.004 ↗
11. A comparative study of high resolution cone beam x-ray tomography and synchrotron tomography applied to Fe- and Al-alloys10.1016/j.ndteint.2010.06.004 ↗
12. Quantitative x-ray tomography10.1179/1743280413Y.0000000023 ↗
13. Quantitative 3D characterization of intermetallic phases in an Al–Mg industrial alloy by x-ray microtomography10.1016/j.scriptamat.2006.03.066 ↗
14. 3D microstructural characterization and mechanical properties of constituent particles in Al 7075 alloys using x-ray synchrotron tomography and nanoindentation10.1016/j.jallcom.2014.03.010 ↗
15. Mechanical properties and reliability of glass-ceramic foam scaffolds for bone repair10.1016/j.matlet.2013.12.037 ↗
16. Stress strain analysis of high porous ceramics10.4028/www.scientific.net/AMR.482-484.1330 ↗
17. Digital rock physics: numerical prediction of pressure-dependent ultrasonic velocities using Micro-CT imaging10.1111/j.1365-246X.2012.05437.x ↗
18. G. Zacher, M. Halisch, P. Westenberger, T. Paul, T. Tan, Quantitative investigation of microstructures within porous rocks by using very high resolution x-ray micro-CT imaging, in: Proceedings of the EAGE/FESM Joint Regional Conference Petrophysics Meets Geoscience, 2014.10.3997/2214-4609.20132108 ↗
19. Biomechanical evaluation of porous bioactive ceramics after implantation: micro CT-based three-dimensional finite element analysis
20. Micro-CT characterization on porosity structure of 3D Cf/SiCm composite10.1016/j.compositesa.2011.07.015 ↗
21. Contrast enhancement of microCT scans to aid 3D modelling of carbon fibre fabric composites10.1007/s10443-013-9326-7 ↗
22. Simulation of damage and failure processes of interpenetrating SiC/Al composites subjected to dynamic compressive loading10.1016/j.actamat.2014.06.045 ↗
23. XCT analysis of the influence of melt strategies on defect population in Ti–6Al–4V components manufactured by selective electron beam melting10.1016/j.matchar.2015.02.008 ↗
24. L.A. Fitri, V. Asyana, T. Ridwan, F. Anwary, H. Soekersi, F.D.E. Latief, F. Haryanto, Dual energy micro CT SkyScan 1173 for the characterization of urinary stone, in: Proceedings of the 13th South-East Asian Congress of Medical Physics, 2016.10.1088/1742-6596/694/1/012053 ↗
25. Noise considerations in dual energy CT scanning10.1118/1.594520 ↗
26. An iterative dual energy CT reconstruction method for a K-edge contrast material
27. Dual-energy computed tomography in pulmonary embolism10.1259/bjr/16337436 ↗
28. Image fusion in dual energy computed tomography for detection of various anatomic structures--effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality10.1016/j.ejrad.2011.02.023 ↗
29. Evaluation of non-linear blending in dual-energy computed tomography10.1016/j.ejrad.2008.09.017 ↗
30. Dual energy CT: how to best blend both energies in one fused image?
31. Enhanced material contrast by dual-energy MicroCT imaging. 〈http://bruker-microct.com/products/downloads.htm/〉, 2013.
32. Importance of the α→β transformation in the variant selection mechanisms of thermomechanically processed titanium alloys10.1016/j.scriptamat.2008.05.013 ↗
33. Microstructural formation in Ti alloys: in-situ characterization of phase transformation kinetics10.1007/s11837-007-0011-x ↗