Sputter deposition of NiTi to investigate the Ti loss rate as a function of composition from cast melted targets
Source abstract
Abstract
Abstract Off-stoichiometric NiTi sputtering targets were manufactured by cast melting in order to sputter Ni-rich NiTi thin films. Crystalline samples, which reveal a martensitic transformation, were fabricated by magnetron sputtering and subsequent thermal treatment. A systematic investigation to determine the deviation between target and substrate composition was carried out by means of microprobe analysis. Typical loss rates in sputtering targets with Ti content higher than 49.5 at.% were in the order of 4.3 at.%, whereas more Ni-rich targets revealed a Ti loss rate of only 0.5–1.5 at.%. Sacrificial layer technique was applied to obtain free-standing NiTi films. Transformation temperatures and hysteresis properties of the martensitic transformation were characterised by differential scanning calorimetry (DSC) but showed only minor differences concerning composition. Free-standing films obtained from the Ti–53.1 Ni–46.9 at.% sputtering target revealed superelastic properties at 40 °C as demonstrated by tensile testing.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · High Entropy Alloys Studies · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Duerig · Mater. Sci. Eng. A · 1999 · 273–275 · 14910.1016/S0921-5093(99)00294-4 ↗
2. Gupta · Actuator · 2002 · 2002 · 355
3. Kohl · Mater. Sci. Eng. A · 1999 · 275 · 78410.1016/S0921-5093(99)00416-5 ↗
4. Beensh-Marchwicka · Vacuum · 1999 · 53 · 4710.1016/S0042-207X(98)00420-5 ↗
5. Winzek · Z. Metallkd. · 1999 · 90 · 796
6. T. Saburi, in: K. Otsuka, C.M. Wayman (Eds.), Shape Memory Materials, Cambridge University Press, UK, 1998, p. 72.
7. S. Miyazaki, K. Nomura, in: Proceedings of the IEEE Micro Electro Mechanical Systems (MEMS94), Oiso, Japan, 1994, p. 176.
8. Gyobu · Mater. T. JIM · 1996 · 37 · 69710.2320/matertrans1989.37.697 ↗
9. Quandt · Sens. Actuators A · 1996 · 53 · 43410.1016/0924-4247(96)01147-8 ↗
10. W. Siegert, Optimierung von Formgedächtnislegierungen für den Einsatz von Kopplungstechnik, Ph.D. Thesis, VDI Verlag, Düsseldorf, 2003.
11. Saburi · J. Phys. Colloq. · 1982 · 43 · C4
12. Busch · J. Appl. Phys. · 1990 · 68 · 622410.1063/1.346914 ↗