A 12 month in vivo study on the response of bone to a hydroxyapatite–polymethylmethacrylate cranioplasty composite
Source abstract
Abstract
We investigated the osteoconductivity and biocompatibility in vivo of a new hydroxyapatite-polymethylmethacrylate (HA-PMMA) composite developed for use as an implant material for cranioplasty, which is expected to have the good osteoconductivity of HA together with the strength and ease of handling of PMMA. The HA-PMMA composites were implanted in eight full-grown beagles and then 6, 12, 24 weeks and 1 year after implantation, the animals were sacrificed and the implanted materials removed along with the surrounding tissues. Extirpated specimens were studied using an optical microscope and micro-computed tomography (micro-CT). Fibrous connective tissue was prominent in the interface of the composite at 6 weeks. New bone formation was seen around the implant, 12 and 24 weeks after operation. At 1 year, new bone filled in the interface of the HA-PMMA composite and adhered to the surrounding autogenous bone. Mixing HA and PMMA did not interfere with the osteoconductivity of the HA component. In micro-CT findings, the new bone growing on the HA-PMMA composite could be seen attaching preferentially to HA particles exposed at the composite surface, rather than the PMMA. This study demonstrated that this HA-PMMA composite is a good candidate for cranial bone implants due to its good osteoconductivity and biocompatibility.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Facial Trauma and Fracture Management · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. New calcium phosphate ceramic material for bone and tooth implants10.1177/00220345710500041201 ↗
2. Porous hydroxyapatite ceramics and their ability to be fixed by commercially available screw10.1016/S0142-9612(99)00063-0 ↗
3. Sequential histological Examination and morphometric analysis of osteogenesis in the pores of porous hydroxyapatite with attachment of vascularization periosteum
4. Treatment of large complex cranial bone defects by using hydroxyapatite ceramic implants10.1097/00006534-199908000-00003 ↗
5. Current concepts in cranioplasty10.1016/0022-3913(79)90332-9 ↗
6. Correlation between substratum roughness and wettability, cell adhesion, and cell migration10.1002/(SICI)1097-4636(199707)36:1<99::AID-JBM12>3.0.CO;2-E ↗
7. Cranial reconstruction with computer-generated hard-tissue replacement, patient-matched implants: indications, surgical technique, and long-term follow-up10.1097/00006534-200203000-00005 ↗
8. Biomechanical testing of alloplastic PMMA cranioplasty materials10.1097/00001665-200501000-00028 ↗
9. Craniofacial reconstruction with computer-generated HTR patient-matched implants
10. Validation of computer-assisted manufactures of titanium plates for cranioplasty10.1016/S0901-5027(99)80165-9 ↗
11. A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome10.1080/02688699943088 ↗
12. Titanium mesh and hydroxypatite cement cranioplasty: a report of 20 cases10.1053/joms.2002.30575 ↗
13. Okii N, Nishimura S, Kurisu K, Takeshima Y, Uozumi T. In vivo histological changes occurring in hydroxyapatite cranial reconstruction. 2001;41:100–4.10.2176/nmc.41.100 ↗
14. Direct electron microscopy studies of the bone–hydroxyapatite interface10.1002/jbm.820180702 ↗
15. Porous HA ceramic for bone replacement: role of the pores and interconnections-experimental study in the rabbit
16. Determinations of strength of synthetic hydroxyapatite ceramic implants10.1097/00006534-199809010-00027 ↗
17. Clinical outcome in cranioplasty: critical review in long-term follow-up10.1097/00001665-200303000-00003 ↗
18. Polymethylmethacrylate-based bone cement modified with hydroxyapatite10.1002/(SICI)1097-4636(1999)48:2<150::AID-JBM9>3.0.CO;2-D ↗
19. Effect of particles and interface conditions on fibrous tissue interposition between bone and implant. A particle challenge model in rabbit
20. Biological and mechanical properties of PMMA-based bioactive bone cements10.1016/S0142-9612(00)00097-1 ↗
21. Comprehensive biocompatibility testing of a new PMMA–HA bone cement versus conventional PMMA cement in vitro10.1163/156856203322553491 ↗
22. In vivo evaluation of a new polymethylmetacrirate cement reinforced with hydroxyapatite