A gold nanoparticles/sol–gel composite architecture for encapsulation of immunoconjugate for reagentless electrochemical immunoassay
Source abstract
Abstract
A highly hydrophilic, non-toxic and conductive colloidal gold nanoparticle/titania sol-gel composite membrane with a low contact angle was prepared on a glassy carbon electrode via a vapor deposition method. With human chorionic gonadotrophin (hCG) as a model antigen and encapsulation of horseradish peroxidase-labeled hCG antibody (HRP-anti-hCG) in the composite architecture, this membrane could be used for reagentless electrochemical immunoassay. It displayed a porous and homogeneous composite architecture without the aggregation of the immobilized protein molecules. The presence of gold nanoparticles provided a congenial microenvironment for adsorbed biomolecules and decreased the electron transfer impedance, leading to a direct electrochemical behavior of the immobilized HRP. The formation of immunoconjugate by a simple one-step immunoreaction between hCG in sample solution and the immobilized HRP-anti-hCG introduced a barrier of direct electrical communication between the immobilized HRP and the electrode surface. Under optimal conditions, the hCG analyte could be determined in two linear ranges from 0.5 to 5.0 mIU/mL and 5.0 to 30 mIU/mL with a relatively low detection limit of 0.3 mIU/mL at 3sigma. The hCG immunosensor exhibited good precision, high sensitivity, acceptable stability, accuracy and reproducibility. This composite membrane could be used efficiently for the entrapment of different biomarkers and clinical applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · Electrochemical Analysis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Can affinity sensors be used to detect food contaminants?10.1021/ac002953l ↗
2. Immunochemical methods for environmental analysis10.1021/ac00026a001 ↗
3. Enzyme-based biosensors for in vivo measurements10.1021/cr990003y ↗
4. Rapid and sensitive chemiluminescent enzyme immunoassay for measuring tumor markers10.1093/clinchem/37.9.1639 ↗
5. Electrochemical immunoassays10.1007/s002160051557 ↗
6. An indirect perfluorosulfonated ionomer coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin10.1021/ac981216a ↗
7. Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system10.1021/ac0110348 ↗
8. Separation-free sandwich enzyme immunoassays using microporous gold electrodes and self-assembled monolayer/immobilized capture antibodies10.1021/ac00081a003 ↗
9. On applicability of laccase as label in the mediated and mediatorless electroimmunoassay: effect of distance on the direct electron transfer between laccase and electrode10.1016/S0956-5663(00)00135-4 ↗
10. Electrochemical immunosensor for carbohydrate antigen 19-9 based on immunological reaction and its immobilization in titania sol–gel matrix10.1016/j.jim.2003.08.014 ↗
11. An antibody-immobilized capillary column as a bioseparator/bioreactor for detection of Escherichia coli O157:H7 with absorbance measurement10.1021/ac0101048 ↗
12. New amperometric and potentiometric immunosensors for anti-human immunoglobulin G determinations10.1016/S0925-4005(99)00035-0 ↗
13. Comparison of 1-naphthyl phosphate and 4-aminophenyl phosphate as enzyme substrates for use with a screen-printed amperometric immunosensor for progesterone in cows, milk10.1016/S0956-5663(99)00019-6 ↗
14. Development of a creatinine ELISA and an amperometric antibody-based creatinine sensor with a detection limit in the nanomolar range10.1021/ac9909047 ↗
15. Immobilization of peroxidase glycoprotein on gold electrodes modified with mixed epoxy-boronic acid monolayers10.1021/ja026658p ↗
16. Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for rapid determination of carcinoma antigen-12510.1021/ac034213t ↗
17. Morphology-dependent electrochemistry of cytochrome c at Au colloid-modified SnO2 electrodes10.1021/ja952951w ↗
18. Electron-transfer communication in glutathione reductase assemblies: electrocatalytic, photocatalytic, and catalytic systems for the reduction of oxidized glutathione10.1021/ja00083a031 ↗
19. An electrochemical metalloimmunoassay based on a colloidal gold label10.1021/ac000781m ↗
20. Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine modified gold electrode10.1006/abio.1999.4360 ↗
21. Preparation and thermal stability of gold nanoparticles in silk-templated porous filaments of titania and zirconia10.1021/cm049548l ↗
22. A method to construct a third-generation horseradish peroxidase biosensor: self-assembling gold nanoparticles to three-dimensional sol–gel network10.1021/ac011116w ↗
23. Preparation of porous titania sol–gel matrix for immobilization of horseradish peroxidase by a vapor deposition method10.1021/ac011290k ↗
24. Amperometric determination of human chorionic gonadotropin by membrane-bound antibody10.1016/0003-2697(79)90784-X ↗
25. Dual immunoassay of human chorionic gonadotropin and human placental lactogen at a miocrofabricated substrate by scanning electrochemical microscopy10.1016/S0022-0728(96)04979-0 ↗
26. Enzyme affinity assays involving a single-use electrochemical sensor. Applications to the enzyme immunoassays of human chorionic gonadotropin hormone and nucleic acid hybridization of human cytomegalovirus DNA10.1002/1521-4109(200012)12:18<1447::AID-ELAN1447>3.0.CO;2-D ↗
27. Optical chip immunoassay for hCG in human whole blood10.1016/S0956-5663(00)00118-4 ↗
28. Miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion10.1002/bit.10158 ↗
29. Direct electron transfer at horseradish peroxidase modified electrodes10.1016/0022-0728(92)80140-Y ↗
30. Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: development of amperometric immunosensor electrodes10.1021/ac960290v ↗
31. Sol–Gel derived thick-film amperometric immunosensors10.1021/ac971093e ↗
32. Plant peroxidase
33. Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode10.1016/S0003-2697(02)00014-3 ↗
34. Immobilization of poly(ethylene glycol) or its sulfonate onto polymer surfaces by ozone oxidation10.1016/S0142-9612(00)00400-2 ↗
35. Accuracy of single measurements of pregnancy-associated plasma protein-A, human chorionic gonadotropin and progesterone in the diagnosis of early pregnancy failure10.1016/S0301-2115(01)00470-5 ↗
36. New electrochemical assay of alkaline phosphatase using ascorbic acid 2-phosphate and its application to enzyme immunoassay10.1016/S0003-2670(99)00793-X ↗