journal article·2005-05

Physicochemical characterisation and biological evaluation of hydrogel-poly(ε-caprolactone) interpenetrating polymer networks as novel urinary biomaterials

David S. Jones, David W.J. McLaughlin, Colin P. McCoy, Sean P. Gorman

Biomaterials· Volume 26· Issue 14
Publisher page

Abstract

Hydrogels are frequently employed as medical device biomaterials due to their advantageous biological properties, e.g. resistance to infection and encrustation, biocompatibility; however, their poor mechanical properties generally limit the scope of application to coatings of medical devices. To address this limitation, this study described the formulation of sequential interpenetrating polymer networks (IPN) of poly(-caprolactone) (PCL) and poly(hydroxyethylmethacrylate) (p(HEMA)). IPN containing 20% w/w PCL, p(HEMA), both in the presence or absence of ethyleneglycol dimethacrylate (EGDMA 1% w/w), were prepared by free radical polymerisation. Following preparation the degradation and the mechanical and surface properties of the biomaterials and, in addition, the resistances to microbial adherence and encrustation in vitro were examined. In comparison to p(HEMA) the various IPN exhibited substantially greater tensile properties (ultimate tensile strength, % elongation, Young's modulus) that were accredited to the discrete distribution of PCL within the hydrogel network. The IPN exhibited two glass transition temperatures that were statistically similar to those of the individual components, thereby providing evidence of the immiscible nature of the two polymers. The IPN possessed higher receding contact angles and lower equilibrium water contents in comparison to p(HEMA), whereas the limited degradation of the IPN at both pH 7 and 9 was deemed suitable for clinical usage for periods of at least 4 weeks. The resistances of the various IPN to bacterial adherence and urinary encrustation were examined using in vitro models. Importantly the resistance of the IPN to encrustation was, in general, similar to that of p(HEMA) but greater than that of PCL whereas, the resistance of the IPN to bacterial adherence was frequently greater than that of p(HEMA) and PCL. Therefore, this study has shown that the mechanical properties of p(HEMA) may be substantially increased by the formation of IPN with PCL whilst maintaining other appropriate physicochemical properties and resistances to urinary encrustation and bacterial adherence. It is suggested that these IPN may be suitable for device fabrication thereby expanding the manufacturing application of hydrogels without compromising their potential clinical efficacy.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Central Venous Catheters and Hemodialysis · Surgical Sutures and Adhesives · 3D Printing in Biomedical Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Tunney · 1999 · vol. 310 · 558
2. Design and validation of a dynamic flow model simulating encrustation of biomaterials in the urinary tract10.1211/002235702856 ↗
3. Eradication of endotracheal tube biofilm by nebulised gentamicin10.1007/s00134-002-1223-8 ↗
4. Characterisation and evaluation of novel surfactant bacterial anti-adherent coatings for endotracheal tubes designed for the prevention of ventilator associated pneumonia10.1111/j.2042-7158.2003.tb02432.x ↗
5. Pharmaceutical strategies to prevent ventilator associated pneumonia10.1211/0022357021035 ↗
6. Which indwelling uretheral catheters resist encrustation by Proteus mirabilis Biofilms?10.1046/j.1464-410X.1997.00185.x ↗
7. Design of a simulated urethra model for the quantitative assessment of urinary catheter lubricity
8. Blockage of urinary catheters10.1016/0895-4356(89)90096-6 ↗
9. Sequential polyurethane-poly (methylmethacrylate) interpenetrating polymer networks as ureteral biomaterials
10. Poly(ε-caprolactone) and poly(ε-caprolactone)-polyvinylpyrrolidone-iodine blends as ureteral biomaterials10.1016/S0142-9612(02)00158-8 ↗
11. Comparison of in vitro encrustation on ureteral stent materials10.1016/0142-9612(96)89780-8 ↗
12. Complications of urinary devices
13. Urease induced precipitation of phosphate salts in vitro on indwelling catheters made of different materials10.1007/BF00299063 ↗
14. Urease induced precipitation on latex and silver coated latex in vitro10.1080/21681805.1991.12068897 ↗
15. Bacterial adherence to urethral catheters10.1016/S0022-5347(17)39428-4 ↗
16. Biocompatibility of various indwelling double J stents in vivo and in vitro10.3109/00365599609182343 ↗
17. Chlorhexidine release from poly(ε-caprolactone) films prepared by solvent evaporation10.1016/S0378-5173(96)04675-3 ↗
18. Mechanical performance of polyurethane ureteral stents in vitro and ex vivo
19. Dynamic mechanical properties of polymer-fluid systems10.1016/0032-3861(91)90537-S ↗
20. Physicochemical characterisation of hexetidine impregnated endotracheal tube poly (vinylchloride) and resistance to adherence of respiratory bacterial pathogens10.1023/A:1016104516034 ↗
21. Characterization of biofilm and encrustation on ureteral stents in vivo10.1111/j.1464-410X.1994.tb07557.x ↗
22. Methacrylate polymers and copolymers as urinary tract biomaterials10.1016/S0378-5173(97)04902-8 ↗
23. The role of physiological conditions in the oropharynx on the adherence of respiratory isolates to endotracheal tube polyvinylchloride10.1016/S0142-9612(96)00170-6 ↗
24. Jones · 2002
25. Materials used in urological devices
26. The use of polymer networks to elucidate molecular aspects of rubberlike elasticity10.1007/3-540-11471-8_1 ↗
27. Ward · 1993
28. Mechanical and morphological study of polyurethane/polystyrene interpenetrating polymer networks containing ionic groups10.1002/(SICI)1097-4628(19980321)67:12<1973::AID-APP3>3.0.CO;2-K ↗
29. Polycaprolactone and Its copolymers
30. Mechanical behaviours of fully and semi-interpenetrating polymer networks based on epoxy and acrylics10.1016/S0032-3861(96)00484-3 ↗
31. Interpenetrating polymer networks10.1016/S0966-7822(98)00011-2 ↗
32. Interpenetrating polymer networks of 2-hydroxyethyl methacrylate terminated polyurethanes and polyurethanes10.1016/S0032-3861(98)00204-3 ↗
33. Effect of comonomer concentration and functionality on photopolymerisation rates, mechanical properties and heterogeneity of the polymer10.1002/(SICI)1521-3935(19980601)199:6<1043::AID-MACP1043>3.0.CO;2-Z ↗
34. Relationship between urethral catheter surface properties and lubricity as determined using textural analysis and multiple regression analysis10.1016/j.biomaterials.2003.08.011 ↗
35. Equilibrium swelling properties of weakly ionizable 2-hydroxyethyl methacrylate (HEMA)-based hydrogels10.1002/app.1994.070520609 ↗
36. Aliphatic polyesters.1. The degradation of poly(epsilon-caprolactone) in vivo10.1002/app.1981.070261124 ↗
37. Albumin release from bioerodible hydrogels based on SIPNs composed of PCL and PEG macromer10.1016/S0168-3659(97)00096-5 ↗
38. Evaluation of a polyvinylpyrrolidone-coated biomaterial for urological use10.1016/S0142-9612(02)00206-5 ↗
39. The Effect of poly(HEMA) coating on the adhesion of bacteria to polymer monofilaments10.1016/0378-5173(93)90372-M ↗
40. Current Approaches to the Prevention of Catheter-Related Infections