Short term in vivo biocompatibility testing of biodegradable poly(D,L-lactide)—growth factor coating for orthopaedic implants
Source abstract
Abstract
Fracture healing can be stimulated by exogenous application of growth factors. Using porcine and rat models the efficacy of locally delivered IGF-I and TGF-beta1 from an implant coating has been demonstrated. A thin and biomechanical stable biodegradable poly(D,L-lactide) was used to coat implants and serve as a drug carrier. Due to reports of possible foreign body reactions caused by polymer materials in orthopedic surgery, this study investigated the biocompatibility of the polylactide implant coating and the locally released growth factors during the time course of rat tibial fracture healing (days 5, 10, 15, and 28 after fracture). Monocytes/macrophages and osteoclast were detected using an monoclonal antibody against ED1 (comparable to CD68 in mice and human). The antibody ED1 stains monocytes, macrophages and osteoclast in the bone marrow and in the newly formed fracture callus. A moderate density of the monocytes/macrophages was seen in the proximal part of the medullary canal, but almost no cells were detectable in the region distal to the fracture. The amount of stained cells increased during the observation time with a maximum at days 10 and 15 followed by a decrease at day 28. No differences were detectable between the investigated groups from day 5 to 15 post fracture indicating, that the used poly(D,L-lactide) or the incorporated growth factors do not evoke an elevated immunological response compared to the uncoated titanium implant at the investigated time points. A significantly higher amount of ED1 positive cells was measured 28 days after fracture in the control group compared to the groups with the coated implants. In conclusion, no indication of a foreign body reaction due to the use of the polylactide or the growth factors was found indicating a good short-term biocompatibility of this bioactive coating.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone fractures and treatments · Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Biodegradable poly(D,L-lactide) coating of implants for continuous release of growth factors10.1002/jbm.1040 ↗
2. Controlled release of proteins from their poly(ethylene glycol) conjugates10.1021/bc025652m ↗
3. Biodegradable poly(lactic acid) polymers10.1002/jbm.820050305 ↗
4. Local application of growth factors (insulin-like growth factor-1 and transforming growth factor-β1) from a biodegradable poly(D,L-lactide) coating of osteosynthetic implants accelerates fracture healing in rats10.1016/S8756-3282(00)00456-7 ↗
5. BMP-2 coating of titanium implants increases biomechanical strength and accelerates bone remodeling in fracture treatment
6. Insulin-like growth factor-1 and transforming growth factor-beta1 accelerates osteotomy healing using polylactide-coated implants as a delivery system10.1016/S8756-3282(01)00640-8 ↗
7. IGF-I and TGF-beta1 application by a poly (D,L-lactide)-coated cage promotes intervertebral bone matrix formation in the sheep cervical spine10.1097/00007632-200208150-00006 ↗
8. Spotlight on naturally absorbable osteofixation devices10.1097/00001665-200303000-00021 ↗
9. Polymere als implantatwerkstoffe10.1002/ciuz.19990330505 ↗
10. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers10.1302/0301-620X.72B4.2199452 ↗
11. Osteolytic changes accompanying degradation of absorbable fracture fixation implants10.1302/0301-620X.73B4.1649195 ↗
12. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation—Experimental study in sheep10.1302/0301-620X.78B3.0780369 ↗
13. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
14. Erosion kinetics of hydrolytically degradable polymers10.1073/pnas.90.2.552 ↗
15. Bioresorbable polymers in trauma and bone surgery10.1016/S0020-1383(00)80020-0 ↗
16. IGF-I and TGF-beta 1 incorporated in a poly(D,L-lactide) implant coating stimulates osteoblast differentiation and collagen-1 production but reduces osteoblast proliferation in cell culture10.1002/jbm.b.10513 ↗
17. In vivo biocompatibility and biostability of modified polyurethanes10.1002/(SICI)1097-4636(199708)36:2<246::AID-JBM14>3.0.CO;2-E ↗
18. The role of osteoclast differentiation in aseptic loosening10.1016/S0736-0266(01)00070-5 ↗
19. Development and characterization of a standard closed tibial fracture model in the rat10.1007/s00068-004-1322-z ↗
20. Cell proliferation and differentiation during fracture healing are influenced by locally applied IGF-I and TGF-110.1002/jbm.b.10512 ↗
21. Quantification, localization, and expression of IGF-I and TGF-beta1 during growth factor-stimulated fracture healing10.1007/s00223-003-0117-2 ↗
22. Metallic or absorbable implants for ankle fractures10.3109/17453679608995602 ↗
23. Local delivery of growth factors from coated titanium plates increases osteotomy healing in rats10.1016/j.bone.2004.01.015 ↗
24. Gentamicin coating of metallic implants reduces implant related osteomyelitis in rats10.1016/S8756-3282(03)00050-4 ↗
25. Long-term effects of local growth factor (IGF-I and TGF-[beta]1) treatment on fracture healing
26. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation10.1016/S0142-9612(00)00129-0 ↗
27. Adverse tissue reactions to bioabsorbable fixation devices10.1097/00003086-200002000-00026 ↗
28. Absorbable polylactide pins versus metallic Kirschner wires in the fixation of cancellous bone osteotomies in rats
29. Soft tissue reactions of different biodegradable polylactide implants10.1016/S0142-9612(03)00496-4 ↗