Sustained release from biodegradable metallic matrix—The entrapment of drugs within iron
Source abstract
Abstract
Abstract Iron and its alloys have been widely used for variety of medical implants. These are used for long term applications as cheap implants with high inertness and low corrosion rate, and also as implants with high biocompatibility (the fourth-generation type). Such degrading implants can provide a temporary scaffold while the body heals. In addition to the needed mechanical support, it is highly desirable to provide local drug therapy, providing antibacterial properties, preventing rejection of the implant, and more. So far, the combination of a degradable metallic implant which serves also as a three-dimensional matrix for drug release, remained un-answered. Here we present, we believe for the first time realization of this concept: Entrapment of drugs within a 3D degradable metal matrix—iron—from which the entrapped drugs are sustain-released. This new type of material is based on the molecular metals entrapment materials methodology, resulting in drugs@Fe. Two drugs have been successfully entrapped and released: chlorhexidine - an antiseptic drug, and rapamycin—used for avoiding transplant rejection. The delivery profiles of the composites were studied in two forms—powders and pressed discs showing two different types of drug release profiles. The release of the drugs from the powder hasa first order release profile, while the pressed disk is a slower, zero-order release profile, which is highly desirable due to the constant rate of the release. Full characterization of the metallic biomaterials is provided, including XRD, SEM, TGA, elemental analysis, and surface area/porosity analysis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Nanomaterials for catalytic reactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. A review on surface treatment of stainless steel orthopedic implants
2. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
3. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
4. Biodegradable metals for cardiovascular stent application: interests and new opportunities10.3390/ijms12074250 ↗
5. Biodegradable Metal Stents: A Focused Review on Materials and Clinical Biodegradable Metal Stents10.1166/jbt.2014.1263 ↗
6. Metallic implant drug/device combinations for controlled drug release in orthopaedic applications10.1016/j.jconrel.2014.01.026 ↗
7. A Review On : Sustained Released Technology
8. RBS. Review on sustained release matrix tablet
9. Entrapment of drugs within metallic platinum and their delivery10.1021/acsbiomaterials.9b00379 ↗
10. Sustained release from a metal—Analgesics entrapped within biocidal silver10.1038/s41598-017-03195-w ↗
11. Molecularly doped metals10.1021/ar4001982 ↗
12. Recent progress in the study of molecularly doped metals10.1002/adma.201706804 ↗
13. A concept in bactericidal materials: the entrapment of chlorhexidine within silver10.1002/adfm.200902393 ↗
14. Bioactive doped metals: high synergism in the bactericidal activity of chlorhexidine@silver towards wound pathogenic bacteria10.1039/c3ra41196f ↗
15. An antibacterial copper composite more bioactive than metallic silver10.1039/C6TB00719H ↗
16. Synthesis of Fe-nano particles obtained by borohydride reduction with solvent
17. Development, characterization, and anti-microbial efficacy of hydroxyapatite-chlorhexidine coatings produced by surface-induced mineralization10.1002/1097-4636(2000)53:4<400::AID-JBM14>3.0.CO;2-Z ↗
18. Polymeric multilayers that localize the release of chlorhexidine from biologic wound dressings10.1016/j.biomaterials.2012.05.068 ↗
19. Design of infection-resistant antibiotic-releasing polymers: I. Fabrication and formulation10.1016/S0168-3659(99)00106-6 ↗
20. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices10.1016/j.jconrel.2004.04.011 ↗
21. Clinical and Angiographic Outcome After Sirolimus- Eluting Stent Implantation in Aorto-Ostial Lesions10.1016/j.jacc.2004.05.058 ↗
22. Mixing does the magic: a rapid synthesis of high surface area noble metal nanosponges showing broadband nonlinear optical response10.1021/nn100320s ↗
23. Davis · 200
24. Physisorption of gases , with special reference to the evaluation of surface area and pore size distribution (IUPAC Technical Report)10.1515/pac-2014-1117 ↗
25. An estimation of the correctness of XRD results obtained from the analysis of materials with bimodal crystallite size distribution10.1039/C5CE01799H ↗
26. Aggregate morphology of nano-TiO2: role of primary particle size, solution chemistry, and organic matter10.1039/c2em30680h ↗
27. Achieving zero-order release kinetics using multi-step diffusion-based drug delivery
28. In vitro and in vivo corrosion properties of new iron—manganese alloys designed for cardiovascular applications10.1002/jbm.b.33234 ↗
29. Formulation and Characterization of New Layered Diffusional Matrices for Zero-Order Sustained Release.10.1016/s0168-3659(97)00207-1 ↗
30. Medical Devices in Orthopedic Applications10.1177/0192623307310951 ↗
31. Ratner · 2013