journal article·2017-03-01

Label-free detection of hepatitis B virus using solution immersed silicon sensors

Mangesh S. Diware, Hyun Mo Cho, Won Chegal, Yong Jai Cho, Sang Won O, Se-Hwan Paek, Dong Soo Kim, Kyeong-Suk Kim, Yoon Gi Min, Jae Heung Jo, ChaeHo Shin

Biointerphases· Volume 12· Issue 1
Publisher page

Abstract

Highly sensitive solution immersed silicon (SIS) biosensors were developed for detection of hepatitis B virus (HBV) infection in the early stage. The ultrasensitivity for overlayer thickness at the nonreflecting condition for the p-polarized wave is the basis of SIS sensing technology. The change in thickness due to biomolecular interactions and change in refractive index of the surrounding buffer medium were assessed simultaneously using two separate ellipsometric parameters (Ψ and Δ), respectively, from a single sensing spot. A direct antigen-antibody affinity assay was used to detect and quantify hepatitis B surface antigen (HBsAg), which is the early stage biomarker for HBV infection. The detection limit of 10 pg/ml was achieved for HBsAg in the human blood serum, which is comparable with the results of enzyme-linked immunosorbent assay and other hybrid assays. The SIS sensor's response time was less than 10 min. The SIS sensors exhibit excellent stability and high signal-to-noise ratio, and are cost-effective, which makes them a suitable candidate for point-of-care applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Bacteriophages and microbial interactions · Immunotherapy and Immune Responses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Korea Research Institute of Standards and Science Center for Nanometrology, , Daejeon 34113, South Korea

Korea University Department of Bio-Microsystem Technology, , Seoul 02841, South Korea

Chosun University Department of Mechanical System Engineering, , Gwangju 61452, South Korea

Hannam University Department of Photonics and Sensors, , Daejeon 306791, South Korea

Funding

Ministry of Trade, Industry and Energy

References (25)

Show source-provided references
1. Hepatology · 2001 · 34 · 122510.1053/jhep.2001.29401 ↗
2. N. Engl. J. Med. · 2004 · 350 · 111810.1056/NEJMra031087 ↗
3. World Health Organization, “Hepatitis B,” http://www.who.int/mediacentre/factsheets/fs204/en/, accessed 6 September 2016.
4. Epidemiol. Rev. · 2006 · 28 · 11210.1093/epirev/mxj009 ↗
5. Clin. Biochem. · 2011 · 44 · 119910.1016/j.clinbiochem.2011.07.002 ↗
6. Expert Rev. Gastroenterol. Hepatol. · 2008 · 2 · 55310.1586/17474124.2.4.553 ↗
7. Can. J. Infect. Dis. Med. Microbiol. · 2005 · 16 · 6510.1155/2005/450574 ↗
8. Biosens. Bioelectron. · 2014 · 56 · 28610.1016/j.bios.2014.01.035 ↗
9. RSC Adv. · 2015 · 5 · 3815210.1039/C5RA03467A ↗
10. RSC Adv. · 2015 · 5 · 9202510.1039/C5RA16204A ↗
11. Analyst · 2015 · 140 · 762210.1039/C5AN01634G ↗
12. Talanta · 2010 · 82 · 168010.1016/j.talanta.2010.07.040 ↗
13. Biosens. Bioelectron. · 2009 · 25 · 13010.1016/j.bios.2009.06.015 ↗
14. Sens. Actuators B · 2005 · 111–112 · 41610.1016/j.snb.2005.03.055 ↗
15. Biosens. Bioelectron. · 2011 · 28 · 26310.1016/j.bios.2011.07.030 ↗
16. Biosens. Bioelectron. · 2017 · 87 · 24210.1016/j.bios.2016.08.049 ↗
17. de Mol · 2010 · 5510.1007/978-1-60761-670-2 ↗
18. Analyst · 2015 · 140 · 70610.1039/C4AN01584C ↗
19. J. Opt. Soc. Am. · 1967 · 57 · 68310.1364/JOSA.57.000683 ↗
20. Appl. Opt. · 1983 · 22 · 415510.1364/AO.22.004155 ↗
21. 2003
22. World J. Gastroenterol. · 2014 · 20 · 1248510.3748/wjg.v20.i35.12485 ↗
23. Analyst · 2013 · 138 · 621910.1039/c3an01394d ↗
24. Talanta · 2010 · 82 · 80310.1016/j.talanta.2010.05.059 ↗
25. Sensors · 2012 · 12 · 1009710.3390/s120810097 ↗