Abstract

Low impedance at the interface between tissue and conducting electrodes is of utmost importance for the electrical recording or stimulation of heart and brain tissue. A common way to improve the cell–metal interface and thus the signal-to-noise ratio of recordings, as well as the charge transfer for stimulation applications, is to increase the electrochemically active electrode surface area. In this paper, we propose a method to decrease the impedance of microelectrodes by the introduction of carbon nanotubes (CNTs), offering an extremely rough surface. In a multistage process, an array of multiple microelectrodes covered with high quality, tightly bound CNTs was realized. It is shown by impedance spectroscopy and cardiac myocyte recordings that the transducer properties of the carbon nanotube electrodes are superior to conventional gold and titanium nitride electrodes. These findings will be favorable for any kind of implantable heart electrodes and electrophysiology in cardiac myocyte cultures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University of Applied Sciences Aschaffenburg 1 BioMEMS-Lab, Department of Engineering, , Aschaffenburg, 63743, Germany

Technische Universität Darmstadt 2 Department of Chemistry, Eduard-Zintl Institute for Inorganic und Physical Chemistry, , Darmstadt, 64287, Germany

References (18)

Show source-provided references
1. J Mater Chem · 2008 · 18 · 518110.1039/b805878b ↗
2. Nanotechnology · 2011 · 22 · 26510410.1088/0957-4484/22/26/265104 ↗
3. Nat Nanotechnol · 2008 · 4 · 12610.1038/nnano.2008.374 ↗
4. IEEE Trans Biomed Eng · 2006 · 53 · 73810.1109/TBME.2006.870239 ↗
5. Annu Rev Biomed Eng · 2008 · 10 · 27510.1146/annurev.bioeng.10.061807.160518 ↗
6. Nano Lett · 2010 · 10 · 432110.1021/nl1013986 ↗
7. Biosens Bioelectron · 2009 · 24 · 194210.1016/j.bios.2008.09.036 ↗
8. Nanotechnology · 2006 · 17 · 39110.1088/0957-4484/17/2/008 ↗
9. J Mater Chem · 2010 · 20 · 171710.1039/b919579c ↗
10. Nano Lett · 2012 · 12 · 183110.1021/nl204064s ↗
11. Br Med J · 1889 · 1 · 34810.1136/bmj.1.1468.348 ↗
12. Drug Saf · 2004 · 27 · 76310.2165/00002018-200427110-00002 ↗
13. Pacing Clin Electrophysiol · 2011 · 34 · 101310.1111/j.1540-8159.2011.03150.x ↗
14. IEEE Trans Biomed Eng · 2007 · 54 · 112110.1109/TBME.2007.891169 ↗
15. Nano Lett · 2004 · 4 · 51710.1021/nl035258c ↗
16. 2001
17. J Neural Eng · 2006 · 3 · 9510.1088/1741-2560/3/2/003 ↗
18. Chem Rev · 2006 · 106 · 110510.1021/cr050569o ↗