journal article·2017-08-01

Multilayer poly(3,4-ethylenedioxythiophene)-dexamethasone and poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate-carbon nanotubes coatings on glassy carbon microelectrode arrays for controlled drug release

Elisa Castagnola, Stefano Carli, Maria Vomero, Alice Scarpellini, Mirko Prato, Noah Goshi, Luciano Fadiga, Sam Kassegne, Davide Ricci

Biointerphases· Volume 12· Issue 3
Publisher page

Abstract

The authors present an electrochemically controlled, drug releasing neural interface composed of a glassy carbon (GC) microelectrode array combined with a multilayer poly(3,4-ethylenedioxythiophene) (PEDOT) coating. The system integrates the high stability of the GC electrode substrate, ideal for electrical stimulation and electrochemical detection of neurotransmitters, with the on-demand drug-releasing capabilities of PEDOT-dexamethasone compound, through a mechanically stable interlayer of PEDOT-polystyrene sulfonate (PSS)-carbon nanotubes (CNT). The authors demonstrate that such interlayer improves both the mechanical and electrochemical properties of the neural interface, when compared with a single PEDOT-dexamethasone coating. Moreover, the multilayer coating is able to withstand 10 × 106 biphasic pulses and delamination test with negligible change to the impedance spectra. Cross-section scanning electron microscopy images support that the PEDOT-PSS-CNT interlayer significantly improves the adhesion between the GC substrate and PEDOT-dexamethasone coating, showing no discontinuities between the three well-interconnected layers. Furthermore, the multilayer coating has superior electrochemical properties, in terms of impedance and charge transfer capabilities as compared to a single layer of either PEDOT coating or the GC substrate alone. The authors verified the drug releasing capabilities of the PEDOT-dexamethasone layer when integrated into the multilayer interface through repeated stimulation protocols in vitro, and found a pharmacologically relevant release of dexamethasone.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · Electrochemical sensors and biosensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Center for Translational Neurophysiology of Speech and Communication, Istituto Italiano di Tecnologia , Via Fossato di Mortara 17/19, 44121 Ferrara, Italy

MEMS Research Lab., Department of Mechanical Engineering, College of Engineering, San Diego State University , 5500 Campanile Drive, San Diego, California 92182-1323 and , Box 37, 1414 NE 42nd St., Suite 204, Seattle, Washington 98105-6271

Center for Sensorimotor Neural Engineering (CSNE) , 5500 Campanile Drive, San Diego, California 92182-1323 and , Box 37, 1414 NE 42nd St., Suite 204, Seattle, Washington 98105-6271

Electron Microscopy Facility, Istituto Italiano di Tecnologia , Via Morego 30, 16163 Genova, Italy

Materials Characterization Facility, Istituto Italiano di Tecnologia , Via Morego 30, 16163 Genova, Italy

Center for Translational Neurophysiology of Speech and Communication, Istituto Italiano di Tecnologia , Via Fossato di Mortara 17/19, 44121 Ferrara, Italy and , Via Fossato di Mortara 17/19, 44121 Ferrara, Italy

Section of Human Physiology, University of Ferrara , Via Fossato di Mortara 17/19, 44121 Ferrara, Italy and , Via Fossato di Mortara 17/19, 44121 Ferrara, Italy

Funding

National Science Foundation

References (49)

Show source-provided references
1. Nat. Rev. Neurosci. · 2014 · 15 · 31310.1038/nrn3724 ↗
2. Otolaryngol.-Head Neck · 2003 · 129 · 24810.1016/S0194-5998(03)00527-8 ↗
3. Neurosci. Lett. · 1997 · 225 · 1310.1016/S0304-3940(97)00185-7 ↗
4. Nature · 1997 · 389 · 18010.1038/38278 ↗
5. Nano Lett. · 2006 · 6 · 204310.1021/nl061241t ↗
6. J. Micromech. Microeng. · 2016 · 26 · 02501810.1088/0960-1317/26/2/025018 ↗
7. Science · 2015 · 347 · 15910.1126/science.1260318 ↗
8. Biosens. Bioelectron. · 2015 · 67 · 45010.1016/j.bios.2014.09.004 ↗
9. J. Nanosci. Nanotechno. · 2013 · 13 · 18810.1166/jnn.2013.6708 ↗
10. J. Neurosci. Methods · 2005 · 148 · 110.1016/j.jneumeth.2005.08.015 ↗
11. ECS Trans. · 2016 · 72 · 9110.1149/07201.0091ecst ↗
12. J. Neural Eng. · 2014 · 11 · 04601110.1088/1741-2560/11/4/046011 ↗
13. Annu. Rev. Biomed. Eng. · 2008 · 10 · 27510.1146/annurev.bioeng.10.061807.160518 ↗
14. Front. Neuroeng. · 2010 · 3 · 810.3389/fneng.2010.00008 ↗
15. Sens. Actuator, B · 2003 · 89 · 9210.1016/S0925-4005(02)00448-3 ↗
16. Biomaterials · 2008 · 29 · 127310.1016/j.biomaterials.2007.11.022 ↗
17. IEEE Trans. Neural Syst. Rehabil. · 2007 · 15 · 50210.1109/TNSRE.2007.909811 ↗
18. J. Electroanal. Chem. · 1995 · 397 · 16310.1016/0022-0728(95)04156-8 ↗
19. Biomaterials · 2012 · 33 · 587510.1016/j.biomaterials.2012.05.017 ↗
20. ACS Appl. Mater. Interfaces · 2015 · 7 · 1538810.1021/acsami.5b03350 ↗
21. Sci. Adv. · 2017 · 3 · e160044810.1126/sciadv.1600448 ↗
22. Brain Res. · 2007 · 1148 · 1510.1016/j.brainres.2007.02.024 ↗
23. J. Controlled Release · 2010 · 146 · 610.1016/j.jconrel.2010.03.023 ↗
24. J. Controlled Release · 2006 · 110 · 53110.1016/j.jconrel.2005.10.027 ↗
25. Biomaterials · 2017 · 129 · 17610.1016/j.biomaterials.2017.03.019 ↗
26. Biointerphases · 2008 · 3 · 8310.1116/1.2998407 ↗
27. J. Biomed. Mater. Res., A · 2014 · 102 · 274310.1002/jbm.a.34945 ↗
28. J. Mater. Chem. B · 2015 · 3 · 505810.1039/C5TB00384A ↗
29. J. Neural Eng. · 2015 · 12 · 01600810.1088/1741-2560/12/1/016008 ↗
30. Biosensors · 2015 · 5 · 61810.3390/bios5040618 ↗
31. Chem. Rev. · 2008 · 108 · 264610.1021/cr068076m ↗
32. Sci. Rep. · 2017 · 7 · 4033210.1038/srep40332 ↗
33. IEEE Trans. Biomed. Eng. · 2016 · 63 · 11110.1109/TBME.2015.2445713 ↗
34. Front. Neuroeng. · 2012 · 5 · 810.3389/fneng.2012.00008 ↗
35. Proc. Natl. Acad. Sci. U. S. A. · 1986 · 83 · 7210.1073/pnas.83.1.72 ↗
36. J. Biol. Chem. · 1987 · 262 · 1769610.1016/S0021-9258(18)45435-X ↗
37. Synth. Met. · 2014 · 189 · 710.1016/j.synthmet.2013.12.013 ↗
38. Front. Neurosci. · 2016 · 10 · 15110.3389/fnins.2016.00151 ↗
39. ACS Nano · 2013 · 7 · 388710.1021/nn305164c ↗
40. ACS Appl. Mater. Interfaces · 2010 · 2 · 265310.1021/am100480s ↗
41. J. Solid State Electrochem. · 2004 · 8 · 80910.1007/s10008-004-0549-2 ↗
42. 2005
43. J. Phys. Chem. C · 2013 · 117 · 514210.1021/jp312066n ↗
44. J. Am. Chem. Soc. · 2011 · 133 · 941310.1021/ja2030933 ↗
45. J. Electroanal. Chem. · 2000 · 489 · 1710.1016/S0022-0728(00)00206-0 ↗
46. Biomaterials · 2009 · 30 · 363710.1016/j.biomaterials.2009.03.043 ↗
47. J. Biomed. Mater. Res., A · 2015 · 103 · 120010.1002/jbm.a.35252 ↗
48. IEEE Trans. Neural Syst. Rehabil. Eng. · 2003 · 11 · 18610.1109/TNSRE.2003.814800 ↗
49. See supplementary material at http://dx.doi.org/10.1116/1.4993140 for a table comparing values of most relevant parameters between this study and literature, calibration curve for DEX, PEDOT-PSS-CNT electrodeposition plot, equivalent circuit, voltage transients and EIS fitted curves.