Physico-chemical characterisation and biological evaluation of freeze dried chitosan sponge for wound care
Source abstract
Abstract
Haemorrhage is one of the most common cause of mortality if proper action is not taken in a fixed period of time. Over the past three decades, usage of haemostatic materials have been widely introduced for arresting the bleeding. Chitosan is one of the biopolymer which is widely used as a haemostatic agent cross linked using glutaraldehyde and freeze dried to prepare a spongy haemostat. The process of freeze drying has been optimised in a controlled freeze dryer in such a way that we obtain a sponge having good mechanical strength as well as blood absorbing capacity. The morphology and microstructure of the chitosan sponge was observed by scanning electron microscopy (SEM). The chitosan sponge was sterilised using gamma irradiation and sterility studies were carried out to prove the sterile nature of the material. In-vitro cytotoxicity evaluation; in vivo intracutaneous reactivity and Guinea pig maximization test conducted on the gamma irradiated chitosan sponge proved the safety of the chitosan sponge to be suitable for haemostasis.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hemostasis and retained surgical items · Electrospun Nanofibers in Biomedical Applications · Wound Healing and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. “Global status report on road safety” published in June 2009 by the World Health Organization (WHO).
2. Natural–synthetic polyblend nanofibers for biomedical applications10.1002/adma.200802513 ↗
3. Chitosan, hyaluronan and chondroitin sulfate in tissue engineering for cartilage regeneration: a review10.1016/j.carbpol.2012.04.057 ↗
4. Novel chitin and chitosan nanofibers in biomedical applications10.1016/j.biotechadv.2009.11.001 ↗
5. J. Berretta, J.D. Bumgardner, J.A. Jennings, Lyophilized chitosan sponges, 2017, 239–253.10.1016/B978-0-08-100230-8.00010-8 ↗
6. IR spectroscopic determination of CONH content in highly deacetylated chitosan10.1016/0141-8130(80)90056-2 ↗
7. P. Terrill, G. Sussman, M. Bailey, Absorption of blood by moist wound healing dressings, Moist wound healing dressings, 11 (2013) 1.
8. ISO 11737-2: 2009 – Sterilization of medical devices – Microbiological methods – Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process.
9. ISO 10993-5, Biological Evaluation of Medical Devices—Part 5: Tests for in-vitro cytotoxicity, 2009.
10. ISO 10993-10, Biological Evaluation of Medical Devices—Part 10: Tests for Irritation and Skin Sensitization, 2010.
11. Construction of silver sulfadiazine loaded chitosan composite sponges as potential wound dressings10.1016/j.carbpol.2016.11.087 ↗
12. Gu · Carbohydr. Polym. · 2013 · 97 · 6510.1016/j.carbpol.2013.04.060 ↗
13. Development and assessment of hemostasis chitosan dressings10.1016/j.carbpol.2011.03.015 ↗
14. The performance of a fly-larva shell derived chitosan sponge as an absorbabale surgical hemostatic agent10.1016/j.biomaterials.2009.10.023 ↗