Abstract
A new nickel-free austenitic stainless steel, named BIOSSN4, has been recently developed to avoid the sensitivity to Ni ions. In the present study, the blood compatibility of the nickel-free stainless steel was evaluated in vitro by the platelet-rich plasma adhesion test with comparison to 316L stainless steel. The result shows that the nickel-free stainless steel only causes less activation of platelets, which was indicated by their morphology and low spreading. The result suggests that the nickel-free stainless steel should have better blood compatibility compared with 316L stainless steel and, as a bio-material, it should have obvious advantage and potential applications. (c) 2005 Elsevier B.V. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Black · 1998
2. The role of metal corrosion in inflammatory processes: induction of adhesion molecules by heavy metal ions
3. The influence of surface condition on the localized corrosion of 316l stainless steel orthopedic implants10.1023/A:1008918929036 ↗
4. Toxicity and carcinogenicity of nickel compounds10.3109/10408448909029327 ↗
5. Metals and women's health10.1006/enrs.2002.4338 ↗
6. Nickel essentiality, toxicity, and carcinogenicity10.1016/S1040-8428(01)00214-1 ↗
7. High nitrogen containing Ni-free austenitic steel for medical applications10.2355/isijinternational.36.893 ↗
8. Nitrogen bearing austenitic stainless steels for surgical implants10.4028/www.scientific.net/MSF.318-320.569 ↗
9. A new austenitic stainless steel with negligible nickel content: an in vitro and in vivo comparative investigation10.1016/S0142-9612(03)00416-2 ↗
10. Nickel-free stainless steel for medical applications
11. Cytocompatibility evaluation of Ni-free stainless steel manufactured by nitrogen adsorption treatment10.1016/j.msec.2004.08.017 ↗
12. Zhong · 1997
13. Adhesion of albumin on the surface of biomaterials
14. Study of the catalytic polarographic reduction of Ni(II) in the presence of albumin, immunoglobulins and serum proteins. Determination of total proteins in serum10.1016/0003-2670(95)00425-4 ↗
15. Structural studies on metal-serum albumin: III. Slow conformational transition of HSA and BSA induced by Ni2+ ion
16. Binding equilibrium study between Ni(II) and HAS and BSA