EPR dosimetric studies on strontium sulfate rods for possible use in radiotherapy
Source abstract
Abstract
Abstract Radiation-induced radicals in the crystals of strontium sulfate (SS) as rod dosimeters were studied using an electron paramagnetic resonance (EPR) spectrometer. Dosimetric studies were performed in the dose range of 0.5 to 25 Gy for the dosimeters to investigate their potential applications in radiotherapy (60Co γ-rays and high megavoltage X-ray with 6 and 15 MV). Additionally, the response of these dosimeters was compared to the response of alanine pellet dosimeters at the three-beam qualities. Irradiation of SS dosimeters produces five EPR signals, and their intensity increases linearly with increasing absorbed doses from 0.5 to 25 Gy. A peak of a splitting g-factor (g) = 2.01039 was selected for the present evaluations as it has a higher intensity. The change in response of SS rod dosimeters after irradiation does not exceed ±2% over six months, exhibiting good stability. The response of SS dosimeters increases with increasing the incident beam energy from 60Co gamma rays to 16 MV X-ray beam. For alanine dosimeters, a non-significant change is observed under these beam qualities. The response of SS dosimeter at 6 and 15 MV relative to a60Co beam quality increases by about 3.8% and 14.1%, respectively. Moreover, the response of the SS dosimeters increases 2.24% with increasing the dose rate from 100 to 400 cGy/min, while for the alanine dosimeters, the increase in response is less than 0.49%. Environmental factors (relative humidity levels of 0–76% and temperature degrees of 15–30 °C) have a slight impact on the response of SS rods during irradiation. The overall uncertainty of dose monitoring was reported to be ±4.02% (2σ, 95% confidence levels).
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Radiation Effects and Dosimetry · Nuclear Physics and Applications · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. High dose-per-pulse electron beam dosimetry - a model to correct for the ion recombination in the Advanced Markus ionization chamber10.1002/mp.12111 ↗
2. Output factors of ionization chambers and solid state detectors for mobile intraoperative radiotherapy (IORT) accelerator electron beams10.1002/acm2.12522 ↗
3. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers10.1088/0031-9155/61/11/4201 ↗
4. An inexpensive method of small photon field dosimetry with EBT3 radiochromic film10.1007/s12553-018-0233-7 ↗
5. Small field dose correction factors for radiochromic film in lung phantoms10.1002/mp.14799 ↗
6. Effect of ionizing radiation on the colorimetric properties of PVA-GTA Xylenol Orange Fricke gel dosimeters10.1016/j.dyepig.2021.109141 ↗
7. Evaluation of ferrous benzoic methylthymol-blue gel as a dosimeter via magnetic resonance imaging10.1016/j.ejmp.2020.10.006 ↗
8. Improved performance of N-(Hydroxymethyl)acrylamide gel dosimeter using potassium chloride for radiotherapy10.1016/j.radmeas.2021.106542 ↗
9. A novel investigation of the effect of different concentrations of methacrylic acid on the dose response of MAGAT gel dosimeter in intraoperative radiotherapy10.1016/j.radphyschem.2020.109214 ↗
10. Evaluations of N-(Isobutoxymethyl) acrylamide gel dosimeter by NMR technique for radiotherapy and uncertainty in dose measurements10.1016/j.apradiso.2019.04.014 ↗
11. Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans10.1016/j.apradiso.2016.12.004 ↗
12. Al2O3:C and Al2O3:C,Mg optically stimulated luminescence 2D dosimetry applied to magnetic resonance guided radiotherapy10.1016/j.radmeas.2020.106439 ↗
13. Evaluation of breast cancer radiation therapy techniques in outfield organs of rando phantom with thermoluminescence dosimeter
14. Improvement of dose range of thermoluminescence dosimeters applied in radiotherapy10.1080/10420150.2020.1780591 ↗
15. Dosimetric measurement of testicular dose for colorectal cancer using optically-stimulated luminescent dosimeters in radiotherapy10.1016/j.radphyschem.2020.108792 ↗
16. Dosimetric characterization of MgB4O7:Ce,Li as an optically stimulated dosimeter for photon beam radiotherapy10.1016/j.pisc.2019.100397 ↗
17. Alanine dosimetry of proton therapy beams10.1118/1.597911 ↗
18. IAEA high-dose intercomparison in 60Co field10.1016/S0969-8043(00)00067-1 ↗
19. 2013
20. Clinical applications of alanine/electron spin resonance dosimetry10.1007/s00411-013-0509-2 ↗
21. Strategy for finding new materials for ESR dosimeters
22. Lithium formate EPR dosimetry for verifications of planned dose distributions prior to intensity-modulated radiation therapy10.1088/0031-9155/53/17/014 ↗
23. Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy10.1118/1.3475938 ↗
24. The energy dependence of lithium formate and alanine EPR dosimeters for medium energy X rays10.1118/1.3432567 ↗
25. Radiation-induced defects in strontium carbonate rod for EPR dosimetry applications10.1016/j.radphyschem.2016.10.013 ↗
26. Radiation induced radical in barium sulphate for ESR dosimetry: a preliminary study10.1016/j.nimb.2004.05.025 ↗
27. EPR dosimetric properties of nano-barium sulfate10.1016/j.radphyschem.2014.08.019 ↗
28. A study on energy dependence of nano barium sulfate powder using the EPR technique in photon, electron and proton beams10.1016/j.measurement.2021.109108 ↗
29. Strontium sulfate as an EPR dosimeter for radiation technology application10.1016/j.radphyschem.2014.07.009 ↗
30. Magnesium lactate mixed with EVA polymer/paraffin as an EPR dosimeter for radiation processing application10.1016/j.radphyschem.2012.07.018 ↗
31. New alanine/EPR dosimeter using EVA copolymer/paraffin as a binder for high-dose radiation dosimetry: performance characterization10.1080/00914030490502445 ↗
32. FWT-50 SERIES ALANINE PELLET DOSIMETERS. https://www.fwt.com/racm/fwt50ds.htm. (Accessed 25 September 2021).
33. 2006 · 2006
34. Humidity fixed points OF binary saturated aqueous solutions10.6028/jres.081A.011 ↗
35. Calculation of photon mass energy-transfer and mass energy-absorption coefficients10.2307/3578607 ↗
36. Evaluation of dose uncertainty in radiation processing using EPR spectroscopy and butylated hydroxytoluene rods as dosimetry system10.1016/j.radphyschem.2017.05.029 ↗
37. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams10.1088/0031-9155/49/2/006 ↗
38. Sharpe · 1999
39. An investigation of the photon energy dependence of the EPR alanine dosimetry system10.1088/0031-9155/48/12/306 ↗
40. Response of the alanine/ESR dosimetry system to MV X-rays relative to (60)Co radiation10.1088/0031-9155/53/10/020 ↗
41. Gibbons · 2020
42. Dosimetry by ESR spectroscopy of alanine10.1016/0020-708X(82)90238-1 ↗
43. Progress in alanine film/ESR dosimetry
44. Response of alanine dosimeters at very high dose rate10.1016/S0969-8043(96)00281-3 ↗
45. Guide for estimation of measurement uncertainty in dosimetry for radiation processing
46. Sharpe · 2009
47. A study of the alanine dosimeter irradiation temperature coefficient from 25 to 80 °C10.1016/j.radphyschem.2009.03.026 ↗
48. A new label dosimetry system based on pentacosa-diynoic acid monomer for low dose applications10.1016/j.radphyschem.2011.08.011 ↗