The impact of structure and temperature on the mechanical properties and radiopacity of Ta-W coatings for tiny endovascular medical implants
Source abstract
Abstract
The trackability of tiny endovascular medical implants (TEMIs) during and after surgery is a crucial parameter for their accurate implantation and after surgery follow-ups. In this work, novel radiopaque Ta-W coatings were produced by magnetron sputtering deposition and further investigated with the aim to improve X-ray visibility of TEMIs under fluoroscopy imaging. Different deposition strategies, named micro-multilayer (Micro-ML), nano-multilayer (Nano-ML) and co-deposition (Co-dep), and different substrate temperatures (25 °C and 600 °C) were implemented which allowed to tune the morphology, mechanical properties and radiopacity of the coatings, while avoiding the formation of brittle phases, such as β-Ta and β-W. Ta-W coatings produced at high temperature (600 °C) contained stable phases such as α-Ta (bcc) and α-W (bcc), without brittle phases such as β-Ta and β-W. However, traces of β-W and β-Ta were detected in the group of samples produced at low substrate temperature (25 °C). The elastic modulus and the hardness of Micro-ML and Nano-ML were found to increase with increasing temperature, whereas they decreased in the case of samples produced by the Co-dep condition. The chemical state of Ta as well as the proportion of oxidized Ta (Ta-O) detected on all coatings were found to change as a function of the substrate temperature and deposition strategy. Samples with the highest amount of Ta-O at their surfaces showed the lowest corrosion potential. Finally, the samples produced by Micro-ML strategies performed on 600 °C substrates and irradiated according to radiographic imaging of conditions comparable to that of fluoroscopy, exhibited an X-ray contrast improvement of 82%/μm, which was higher than what was found in all other samples. Higher volume fractions of α-W in the coatings resulted in higher X-ray attenuation potential for photons in the energy range typical of fluoroscopy. Overall, the production of Ta-W coatings by the Micro-ML strategy and performed with a substrate temperature of 600 °C seems an optimal approach for the production of highly visible TEMIs in X-ray imaging.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · High Entropy Alloys Studies · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Jia · 2018 · vol. 20 · 46
2. Radiopacity of coronary stents, an in vitro comparative study10.1007/s13239-020-00492-w ↗
3. Griebel · 2021 · 1
4. Impact of stent strut design in metallic stents and biodegradable scaffolds10.1016/j.ijcard.2014.09.143 ↗
5. Mechanically stable tantalum coating on a nano-roughened NiTi stent for enhanced radiopacity and biocompatibility10.1016/j.surfcoat.2016.08.014 ↗
6. Sneha · 2021 · 8569
7. Wolbarst · 2013
8. Webb · 1988
9. Tantalum coated NiTi alloy by PIIID for biomedical application10.1016/j.surfcoat.2012.11.002 ↗
10. A platinum-chromium steel for cardiovascular stents10.1016/j.biomaterials.2010.01.146 ↗
11. Radiopaque markers in endovascular stents--benefit and potential hazards
12. Schewe · 2016
13. Cardiovascular revascularization medicine SICI-GISE position document on the use of the magmaris resorbable magnesium scaffold in clinical practice10.1016/j.carrev.2021.02.003 ↗
14. Tuning Ta coating properties through chemical and plasma etching pre-treatment of NiTi wire substrates
15. The clinical application of porous tantalum and its new development for bone tissue engineering10.3390/ma14102647 ↗
16. Effects of the tantalum intermediate layer on the nanomechanical properties and biocompatibility of nanostructured tantalum/tantalum nitride bilayer coating deposited by magnetron sputtering on the nickel titanium alloy10.1007/s13204-021-01852-1 ↗
17. Development of tantalum oxide (Ta-O) thin film coating on biomedical Ti-6Al-4V alloy to enhance mechanical properties and biocompatibility10.1016/j.ceramint.2015.08.133 ↗
18. Improved biocompatibility of intra-arterial poly-l-lactic acid stent by tantalum ion implantation: 3-month results in a swine model10.3340/jkns.2021.0009 ↗
19. Comparative invitro study on pure metals (Fe, Mn, Mg, Zn and W) as biodegradable metals10.1016/j.jmst.2013.03.019 ↗
20. Composition and in vitro biocompatibility of corroding tungsten coils10.1002/jbm.b.10561 ↗
21. Park · 2018
22. Park · 2018
23. The β to α phase transition of tantalum coatings deposited by modulated pulsed power magnetron sputtering10.1016/j.surfcoat.2012.10.061 ↗
24. FCC tantalum thin films deposited by magnetron sputtering10.1016/j.surfcoat.2018.12.015 ↗
25. Structure, mechanical properties and corrosion resistance of amorphous Ti-Cr-O coatings10.1016/j.surfcoat.2019.06.061 ↗
26. Tribological properties and microstructure of monolayer and multilayer Ta coatings prepared by magnetron sputtering
27. Compositional and tribo-mechanical characterization of Ti-Ta coatings prepared by confocal dual magnetron Co-sputtering10.1002/adem.201700687 ↗
28. Mechanical properties and microstructural stability of CuTa/Cu composite coatings10.1016/j.surfcoat.2019.02.072 ↗
29. Structure, morphology and selected mechanical properties of magnetron sputtered (Mo, Ta, Nb) thin films on NiTi shape memory alloys
30. Ogul · 2022
31. Impact of gold-decorated tantalum oxide (TaOx-Au) nano-probes for low energy cancer diagnostic agent
32. Sazali · 2019
33. Phase tailoring of tantalum thin films deposited in deep oscillation magnetron sputtering mode10.1016/j.surfcoat.2016.08.017 ↗
34. Series · 2019
35. Comparison of atmospheric-pressure plasma versus low-pressure RF plasma for surface functionalization of PTFE for biomedical applications10.1002/ppap.200600012 ↗
36. Deposition of Tungsten – tantalum composite coating on RAFM steel by sputtering deposition process
37. Effect of tantalum interlayer on hydroxyapatite biointerface for orthopedic applications10.1016/j.surfcoat.2022.128882 ↗
38. Substrate heating and post-annealing effect on tungsten/tungsten carbide bilayers grown by non-reactive DC magnetron sputtering10.1016/j.ceramint.2013.02.075 ↗
39. Total pattern fitting for the combined size-strain-stress-texture determination in thin film diffraction10.1016/j.nimb.2009.09.053 ↗
40. Catanio · 2022 · vol. 925
41. Niobium aggregation and vacancylike defect evolution in nanostructured Nb-doped Mg: their role in the kinetics of the hydride-to-metal phase transformation10.1103/PhysRevB.85.214117 ↗
42. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
43. Progress in determination of the area function of indenters used for nanoindentation10.1016/S0040-6090(00)01367-5 ↗
44. Fischer-Cripps · 201110.1007/978-1-4419-9872-9 ↗
45. Electrochemical characterization of cobalt-based alloys using the mini-cell system10.1016/j.dental.2006.01.026 ↗
46. 2014
47. Radiopacity assessment of neurovascular implants10.1515/cdbme-2016-0118 ↗
48. Development and characterization of a multilayer silver/silver-tantalum oxide thin film coating on stainless steel for biomedical applications10.1016/j.ijadhadh.2019.04.010 ↗
49. Sputtering and thin film deposition
50. Structure of β-tantalum-tungsten alloy films produced by the codeposition of sputtered metals10.1134/S1027451014010406 ↗
51. Mechanical and biological properties of graded porous tantalum coatings deposited on titanium alloy implants by vacuum plasma spraying10.1016/j.surfcoat.2019.05.003 ↗
52. Enhancing the adhesion strength of tantalum oxide ceramic thin film coating on biomedical Ti-6Al-4V alloy by thermal surface treatment10.1016/j.ceramint.2015.07.090 ↗
53. Tantalum coating inhibits Ni-migration from titanium out-diffusion in NiTi shape memory biomedical alloy
54. Evaluation of the tantalum-titanium phase diagram from ab-initio calculations10.1016/j.actamat.2016.08.053 ↗
55. Synthesis of tantalum thin films on titanium by plasma immersion ion implantation and deposition10.1016/j.surfcoat.2012.04.044 ↗
56. Atomic-scale diffusion rates during growth of thin metal films on weakly-interacting substrates10.1038/s41598-019-43107-8 ↗
57. A structure zone diagram including plasma-based deposition and ion etching10.1016/j.tsf.2009.10.145 ↗
58. Rubens Barsi Andreeta · 2012
59. Pandian · 2015
60. Recent advances in the development of nano-sculpted films by magnetron sputtering for energy-related applications10.3390/nano10102039 ↗
61. Nonlinear stress intensity factors in fracture mechanics and their applications10.1016/j.prostr.2016.06.096 ↗
62. Effect of tungsten tantalum pre-alloying on the sintering structure of 90(W-Ta)-Ni-Fe alloy10.1016/j.jallcom.2021.161881 ↗
63. Interdiffusion in the CdTe/HgTe system10.1016/0167-577X(82)90006-4 ↗
64. Effect of the thickness of Ti intermediate layer on the microstructure and mechanical properties of the W/Ta multilayer composites10.1016/j.jallcom.2021.158910 ↗
65. Effect of temperature and deposition technology on the microstructure, chemistry and tribo-mechanical characteristics of Ti-B based thin films by magnetron sputtering10.1016/j.surfcoat.2020.126556 ↗
66. In situ phase evolution study in magnetron sputtered tantalum thin films10.1016/S0040-6090(02)00941-0 ↗
67. Residual stress, microstructure, and structure of tungsten thin films deposited by magnetron sputtering10.1063/1.371841 ↗
68. Hao · 2015 · 1
69. Texture, structure and phase transformation in sputter beta tantalum coating10.1016/j.surfcoat.2003.06.008 ↗
70. Wear and corrosion characterization of single and multilayered nanocrystalline tantalum coatings on biomedical grade CoCrMo alloy
71. Beta (β) tungsten thin films: structure, electron transport, and giant spin Hall effect10.1063/1.4919867 ↗
72. Super-stable ultrafine beta-tungsten nanocrystals with metastable phase and related magnetism10.1039/C2NR33484D ↗
73. Solution reduction synthesis and characterizations of HCP Co nanoplatelets10.1016/j.matchemphys.2009.04.022 ↗
74. Mills · 1973 · vol. 609
75. X-ray characterization of oriented β-tantalum films
76. The self-hosting structure of β-Ta10.1107/S0108768101017918 ↗
77. Influence of α- and β-W phases on performance of SMR devices
78. On the origin of the metastable β-Ta phase stabilization in tantalum sputtered thin films10.1016/j.actamat.2016.12.030 ↗
79. Analysis of magnetron-sputtered tantalum coatings versus electrochemically deposited tantalum from molten salt10.1016/S0257-8972(99)00337-0 ↗
80. The impact of sputter conditions on the microstructure and on the resistivity of tantalum thin films10.1016/j.tsf.2008.12.009 ↗
81. How accurate is the fundamental parameter approach? XRF analysis of bulk and multilayer samples10.1002/xrs.1300220109 ↗
82. Thickness determination of metal multilayers by ED-XRF multivariate analysis using Monte Carlo simulated standards10.1016/j.aca.2020.07.047 ↗
83. Temperature dependence of the sticking coefficient in atomic layer deposition10.1016/j.apsusc.2010.01.025 ↗
84. TiOx deposited by magnetron sputtering: a joint modelling and experimental study10.1088/1361-6463/aabb72 ↗
85. Large plastic deformation blistering and helium retention in 5 % tantalum doped tungsten under 60 keV helium ions implantation10.1016/j.fusengdes.2018.06.014 ↗
86. XPS investigation of monatomic and cluster argon ion sputtering of tantalum pentoxide10.1016/j.apsusc.2017.02.006 ↗
87. Ding · 2020
88. AES and XPS study of thin RF-sputtered Ta2O5 layers10.1016/0169-4332(94)00538-9 ↗
89. Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide10.1016/j.tsf.2012.06.088 ↗
90. Antibacterial properties and cytocompatibility of tantalum oxide coatings10.1016/j.surfcoat.2014.03.061 ↗
91. Mechanism of Cs 0 . 33 Ta x W 1-x O 3 in improving the optical property
92. Sci · 2016
93. Corrosion behavior of plasma transferred arc Fe-based coating reinforced by spherical tungsten carbide in hydrochloric acid solutions10.1007/s11595-020-2257-x ↗
94. Effect of molybdenum, manganese and tungsten contents on the corrosion behavior and hardness of iron-based metallic glasses10.1002/maco.201206740 ↗
95. XPS studies on surface reduction of tungsten oxide nanowire film by Ar+ bombardment10.1016/j.elspec.2012.01.004 ↗
96. Bhattarai · 1998 · vol. 40
97. Electrochemical properties of TiWN/TiWC multilayer coatings deposited by RF-magnetron sputtering on AISI 106010.3390/coatings11070797 ↗
98. Development of Tantalum Oxide (Ta-O) thin film coating on biomedical Ti-6Al-4V alloy to enhance mechanical properties and biocompatibility10.1016/j.ceramint.2015.08.133 ↗
99. Marenkova · 2015 · vol. 88 · 398
100. Surface & Coatings Technology Additive manufacturing of tantalum-zirconium alloy coating for corrosion and wear application by laser directed energy deposition on Ti6Al4V10.1016/j.surfcoat.2021.127006 ↗