journal article·2017-10

Comparative evaluation of performance of cold sprayed and bare N06601 superalloy in medical waste incinerator at 900 °C

Harminder Singh, Henna Khosla

Publisher page

Abstract

Abstract Waste Incinerators and waste-to-energy (WTE) plants are viable sources to compensate for the energy (thermal/heat and electricity) requirements, especially in developing countries which are facing shortage of energy. However due to highly corrosive waste these plants are running at low temperature and hence at low efficiency. Since there is no possibility of removal or selection of corrosive waste/fuel as the waste management/disposal is the primary requirement of these plants, therefore in this study efforts are made for comparative performance study of new materials to raise the working temperature of these plants. The present study was planned to test uncoated/bare N06601 superalloy and the effect of surface modification (50%Ni-50%Cr) by cold spray process in the real service medical waste based incinerator environment at 900 °C for 1000 h. The performance has been characterized via surface morphology, phase composition and element concentration using the combined techniques of XRD, SEM/EDX, BSEI and Elemental X-Ray analysis. The chlorine based incinerator environment is found to be so aggressive that corrosive species are able to penetrate through the N06601superalloy specially designed for high temperature applications. Highly corrosive ‘Active-Oxidation’ reaction mechanism is observed in the case of bare alloy, which is not observed in modified alloy.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: High-Temperature Coating Behaviors · Nuclear Materials and Properties · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Failure of Alloy 20 nozzles used for spraying sulfuric acid in an incineration furnace10.1016/j.engfailanal.2015.01.001 ↗
2. Corrosion in biomass combustion: a materials selection analysis and its interaction with corrosion mechanisms and mitigation strategies10.1016/j.corsci.2013.07.013 ↗
3. Air pollution control systems in WTE units: an overview10.1016/j.wasman.2014.05.025 ↗
4. Investigation of chloride deposit formation in a 24 MWe waste to energy plant10.1016/j.fuel.2014.09.112 ↗
5. Reducing high-temperature corrosion on high-alloyed stainless steel superheaters by co-combustion of municipal sewage sludge in a fluidised bed boiler10.1016/j.fuel.2014.09.007 ↗
6. High temperature oxidation of metallic chromium exposed to eight different metal chlorides10.1016/j.corsci.2011.06.007 ↗
7. Evaluation of characteristics and behavior of cold sprayed Ni-20Cr coating at elevated temperature in waste incinerator plant10.1016/j.surfcoat.2014.10.060 ↗
8. Behavior of Ni-based superalloys in an actual waste incinerator plant under cyclic conditions for 1,000 h at 900°C10.5006/1163 ↗
9. Hot corrosion behavior of cold sprayed Ni-50Cr coating in an incinerator environment at 900°C10.1007/s11666-014-0213-z ↗
10. High temperature corrosion behavior of Ni-based superalloy Superni-75 in the real service environment of medical waste incinerator10.1007/s11085-013-9414-y ↗
11. Behavior of cold sprayed super-alloy in incinerator at 900°C10.1179/1743294414Y.0000000390 ↗
12. Corrosion behavior of glass and glass-ceramics made of municipal solid waste incinerator fly ash10.1016/j.wasman.2004.03.008 ↗
13. Investigation into high-temperature corrosion in a large-scale municipal waste-to-energy plant10.1016/j.corsci.2010.07.032 ↗
14. Thermodynamic and kinetic consideration on the corrosion of Fe, Ni and Cr beneath a molten KCl–ZnCl2 mixture10.1016/j.corsci.2005.02.015 ↗
15. Behaviour of alumina-coated 304L steel in a Waste-to-Energy plant10.1016/j.surfcoat.2011.03.054 ↗
16. Evaluation of hot corrosion behaviour of HVOF sprayed NiCrAl coating on superalloys at 900 °C10.1016/j.matchemphys.2008.05.006 ↗
17. Chloridation and oxidation of iron, chromium, nickel and their alloys in chloridizing and oxidizing atmospheres at 400-700°C10.1016/S0010-938X(99)00142-0 ↗
18. High temperature corrosion mechanisms and effect of alloying elements for materials used in waste incineration environment10.1016/S0010-938X(01)00058-0 ↗
19. The role of chlorine in high temperature corrosion in waste-to-energy plants
20. Mechanism of growth, composition and structure of oxide films formed on ferrous alloys in molten salt electrolytes—a review10.1016/j.matchemphys.2004.05.039 ↗
21. The hot corrosion of 310 stainless steel with pre-coated NaCl/Na2SO4 mixtures at 750 °C10.1016/j.matchemphys.2004.10.002 ↗
22. Corrosion behaviour of various model alloys with NaCl–KCl coating10.1016/j.matchemphys.2005.03.015 ↗
23. High temperature oxidation of laser surface treated Fe-Cr alloys in HCl-containing atmosphere10.1016/S0254-0584(98)00059-5 ↗
24. D. O. Albina, N. J.Themelis, Emissions from waste-to-energy: a comparison with coal-fired power plants, Proc. of IMECE’03 (IMECE2003-55295), ASME International Mechanical Engineering Congress & Exposition Washington, D.C. (2003) 16–21.10.1115/IMECE2003-55295 ↗
25. Relationship between ion transport and the failure behavior of epoxy resin coatings10.1016/j.corsci.2013.08.017 ↗
26. Corrosion behavior of Mg–2.4Zn alloy micro-alloyed with Ag and Ca10.1016/j.corsci.2013.09.012 ↗
27. Fabrication of high-pressure cold-sprayed coating on Ni-based superalloy for high temperature corrosive conditions10.1007/s11837-015-1628-9 ↗
28. Characteristic study of cold sprayed N06601 superalloy surface
29. Characteristic study of N07718 superalloy surface prepared by cold spray
30. Microstructure of kinetic spray coatings : a review10.1007/s11666-015-0223-5 ↗
31. The cold spray process and its potential for industrial applications10.1361/105996306X108110 ↗
32. Kinetic spray coatings10.1016/S0257-8972(98)00709-9 ↗
33. From powders to thermally sprayed coatings10.1007/s11666-009-9435-x ↗
34. Evolution of microstructure by high velocity impacts of particles by cold spray10.1080/10426914.2014.994766 ↗
35. Development and characterization of Cr3C2-NiCr coated superalloy by novel cold spray process10.1080/10426914.2014.973599 ↗
36. Development of cold spray from innovation to emerging future coating technology10.1007/s40430-013-0030-1 ↗
37. Cold spray technology: future of coating deposition processes, fratured integrità strutturale10.3221/IGF-ESIS.22.08 ↗
38. Microstructure study of cold sprayed 50%Ni–50%Cr coating on Inconel-60110.1080/02670844.2015.1119507 ↗
39. Formation and growth morphology of oxidation-induced ferrite layer in Fe-Mn-Al-Cr-C alloys10.1007/BF01045765 ↗
40. Influence of manganese on the high-temperature oxidation of iron-chromium alloys10.1002/maco.19890400403 ↗
41. The oxidation of iron-chromium-manganese alloys at 900°C10.1007/BF00938460 ↗
42. Effects of plasma-sprayed NiCrAl/ZrO2 intermediate on the combustion ability of coatings10.1016/S0257-8972(01)01166-5 ↗
43. Steam oxidation resistance of Ni-Cr thermal spray coatings on 9Cr-1Mo steel. Part 1: 80Ni-20Cr10.2355/isijinternational.43.95 ↗
44. George · 2007
45. Application of high temperature corrosion-resistant materials and coatings under severe corrosive environment in waste-to-energy boilers10.1007/s11666-006-9012-5 ↗