Evaluation of Patellar Groove Prostheses in Veterinary Medicine: Review of Technological Advances, Technical Aspects, and Quality Standards
Source abstract
Abstract
This review explores the technological advancements in, engineering considerations regarding, and quality standards of veterinary patellar groove replacement implants. Veterinary-specific regulations for these implants are currently lacking. Therefore, human knee implant benchmarks are used as references. These benchmarks guide evaluation of the surface quality, material selection, biocompatibility, and mechanical performance of the implant to ensure reliability and longevity. Patellar luxation is a common orthopedic disorder in small animals which leads to patellofemoral joint instability and cartilage degeneration, and is often caused by angular limb deformities that disrupt patellar alignment. In severe cases, patellar groove replacement is necessary to restore function and alleviate pain. The implant materials must provide durability, mechanical strength, and biocompatibility to withstand joint forces while ensuring minimal wear. High-quality surface finishes reduce the friction experienced by these materials, improving their long-term performance. Advances in 3D printing allow the creation of patient-specific implants. These implants offer an enhanced anatomical fit and enhanced functionality, which is especially beneficial in complex cases. However, challenges remain in achieving consistent manufacturing quality and economic feasibility. While custom implants are invaluable for difficult cases, standardized designs are sufficient for routine applications. Combining human implant standards with new manufacturing technologies improves veterinary orthopedic solutions. This integration expands the treatment options for patellar luxation and enhances the quality and accessibility of implants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Tendon Structure and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland
CABIOMEDE Ltd., 25-663 Kielce, Poland
Department of Small Animal Surgery and Anaesthesiology, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, 02-787 Warsaw, Poland
Funding
Industrial Doctoral Program 2023
References (92)
Show source-provided references
1. Three-Dimensional-Printed Patient-Specific Osteotomy Guides, Repositioning Guides and Titanium Plates for Acute Correction of Antebrachial Limb Deformities in Dogs10.1055/s-0040-1709702 ↗
2. Liu, W.-C., Robu, I.S., Patel, R., Leu, M.C., Velez, M., and Chu, T.-M.G. (2014). The effects of 3D bioactive glass scaffolds and BMP-2 on bone formation in rat femoral critical size defects and adjacent bones. Biomed. Mater., 9.10.1088/1748-6041/9/4/045013 ↗
3. Hemipelvic and proximal femoral limb salvage endoprosthesis with tendon ongrowth in a dog10.1111/vsu.12955 ↗
4. Custom acetabular prosthesis for total hip replacement: A case report in a dog with acetabular bone loss after femoral head and neck ostectomy10.1111/vsu.13303 ↗
5. Clinical outcomes of patient-specific porous titanium endoprostheses in dogs with tumors of the mandible, radius, or tibia: 12 cases (2013–2016)10.2460/javma.251.5.566 ↗
6. Bilateral Patellar Groove Replacement in a Dog with Iatrogenic Trochlear Groove Damage10.17555/jvc.2016.10.33.5.295 ↗
7. Invited Review-Applications For 3d Printers in Veterinary Medicine10.1111/vru.12176 ↗
8. A surgical technique of medial patellar luxation in dogs
9. Rotation of the femoral trochlea for treatment of medial patellar luxation in a dog10.1111/j.1748-5827.2007.00532.x ↗
10. Computed tomographic measurements of the femoral trochlea in dogs with and without medial patellar luxation10.1111/vsu.13903 ↗
11. Computed Tomographic Trochlear Depth Measurement in Normal Dogs10.1055/s-0038-1668097 ↗
12. Dome trochleoplasty for correction of patella alta and patella luxation in dogs > 20 kg10.2460/javma.23.06.0307 ↗
13. Rectangular Recession Trochleoplasty for Treatment of Patellar Luxation in Dogs and Cats10.1055/s-0038-1632628 ↗
14. Comparison of Trochlear Block Recession and Trochlear Wedge Recession for Canine Patellar Luxation Using a Cadaver Model10.1053/jvet.2001.21391 ↗
15. Computed Tomographic Measurements of the Sulcus Angle of the Femoral Trochlea in Small-Breed Dogs with and without Medial Patellar Luxation10.1055/s-0042-1749151 ↗
16. Computed tomographic localization of the deepest portion of the femoral trochlear groove in healthy dogs10.1111/vsu.13426 ↗
17. Patellar groove replacement in patellar luxation with severe femoro-patellar osteoarthritis10.3415/VCOT-14-07-0106 ↗
18. Panichi, E., Sassaroli, S., Ciccarese, G.M., Riccio, V., Balestriere, C., Barbaccia, M., Cappellari, F., Burkhan, E., and Piccionello, A.P. (2024). Use of a Custom-Made Patellar Groove Replacement in an American Staffordshire Terrier Puppy with a Severe Bone Defect in the Femoral Trochlea Caused by Hematogenous Osteomyelitis. Animals, 14.10.20944/preprints202402.1172.v1 ↗
19. Patellar Groove Replacement in a Cat10.1055/s-0042-1751071 ↗
20. Tobias, K.M., and Johnston, S. (2017). Stifle joint. Veterinary Surgery: Small Animal, Elsevier.
21. Patellar luxation in dogs
22. Rezende, C.M., Torres, R.C.S., Nepomuceno, A.C., Lara, J.S., and Varón, J.A.C. (2016). Patellar Luxation in Small Animals. Canine Medicine–Recent Topics and Advanced Research, InTech.10.5772/65764 ↗
23. Complications Associated with Corrective Surgery for Patellar Luxation in 109 Dogs10.1111/j.1532-950X.2006.00189.x ↗
24. Patellar luxation in dogs10.12968/coan.2019.24.6.293 ↗
25. Grossly apparent cartilage erosion of the patellar articular surface in dogs with congenital medial patellar luxation10.3415/VCOT-07-08-0076 ↗
26. Femur fracture associated with canine patellar groove replacement10.1002/vrc2.699 ↗
27. Proximodistal Alignment of the Canine Patella: Radiographic Evaluation and Association with Medial and Lateral Patellar Luxation10.1111/j.1532-950X.2008.00367.x ↗
28. Measurement of Femoral Trochlear Morphology in Dogs Using Ultrasonography10.1055/s-0043-1770902 ↗
29. Concepts of etiologies and effects of normal human knee pressure variations10.4172/2161-0940.1000172 ↗
30. Murakami, T. (2023). Biomechanics of human and artificial joints. Biotribology of Natural and Artificial Joints, Elsevier.10.1016/B978-0-12-823669-7.00008-9 ↗
31. (2024). Implants for Surgery–Metallic Materials–Part 1: Wrought Stainless Steel (Standard No. ISO 5832-1).
32. (2018). Implants for Surgery–Metallic Materials–Part 2: Unalloyed Titanium (Standard No. ISO 5832-2).
33. (2021). Implants for Surgery–Metallic Materials–Part 3: Wrought Titanium 6-Aluminium 4-Vanadium Alloy (Standard No. ISO 5832-3).
34. (2024). Implants for Surgery–Metallic Materials–Part 4: Cobalt-Chromium-Molybdenum Casting Alloy (Standard No. ISO 5832-4).
35. (2019). Implants for Surgery–Metallic Materials–Part 12: Wrought Cobalt-Chromium-Molybdenum Alloy (Standard No. ISO 5832-12).
36. (2018). Biological Evaluation of Medical Devices–Part 1: Evaluation and Testing within a Risk Management Process (Standard No. ISO 10993-1).
37. (2009). Biological Evaluation of Medical Devices–Part 5: Tests for In Vitro Cytotoxicity (Standard No. ISO 10993-5).
38. (2017). Biological Evaluation of Medical Devices–Part 11: Tests for Systemic Toxicity (Standard No. ISO 10993-11).
39. (2007). Implants for Surgery–Components for Partial and Total Knee Joint Prostheses–Part 1: Classification, Definitions, and Designation of Dimensions (Standard No. ISO 7207-1).
40. (2011). Implants for Surgery–Components for Partial and Total Knee Joint Prostheses–Part 2: Articulating Surfaces Made of Metal, Ceramic, and Plastic Materials (Standard No. ISO 7207-2).
41. (2016). Medical Devices—Quality Management Systems—Requirements for Regulatory Purposes (Standard No. ISO 13485).
42. (2009). Implants for Surgery–Wear of Total Knee-Joint Prostheses–Part 1: Loading and Displacement Parameters for Wear-Testing Machines with Load Control and Corresponding Environmental Conditions for the Test (Standard No. ISO 14243-1).
43. (2016). Implants for Surgery–Wear of Total Knee-Joint Prostheses–Part 2: Methods of Measurement (Standard No. ISO 14243-2).
44. (2007). Implants for Surgery–Joint Replacement Implants–Particular Requirements (Standard No. ISO 21534).
45. (2023). Non-Active Surgical Implants–Joint Replacement Implants–Specific Requirements for Hip-Joint Replacement Implants (Standard No. ISO 21535).
46. A comparative anatomical study of the human knee and six animal species10.1016/j.knee.2011.07.005 ↗
47. Waqar, A., Phoenix, D., Jackson, M., and Charalambous, P. (2020). Engineering advances in knee arthroplasty. Advances in Medical and Surgical Engineering, Academic Press.
48. Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting10.1016/j.jmbbm.2011.05.010 ↗
49. Bal, B.S., and Oonishi, H. (2003). Ceramic femoral components in total knee replacement. Bioceramics in Joint Arthroplasty. Ceramics in Orthopaedics, Steinkopff.10.1007/978-3-642-85763-8_20 ↗
50. The All-Ceramic Knee Endoprosthesis—The Gap Between Expectation and Experience with Ceramic Implants10.1053/j.sart.2013.01.010 ↗
51. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait10.1186/s40634-017-0078-4 ↗
52. Structural stability of a polyetheretherketone femoral component—A 3D finite element simulation10.1016/j.clinbiomech.2019.09.001 ↗
53. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study10.1177/0954411916667410 ↗
54. Galas, A., Banci, L., and Innocenti, B. (2023). The Effects of Different Femoral Component Materials on Bone and Implant Response in Total Knee Arthroplasty: A Finite Element Analysis. Materials, 16.10.3390/ma16165605 ↗
55. In vitro and in vivo evaluation of a shape memory polymer foam-over-wire embolization device delivered in saccular aneurysm models10.1002/jbm.b.33489 ↗
56. Memarian, P., Pishavar, E., Zanotti, F., Trentini, M., Camponogara, F., Soliani, E., Gargiulo, P., Isola, M., and Zavan, B. (2022). Active Materials for 3D Printing in Small Animals: Current Modalities and Future Directions for Orthopedic Applications. Int. J. Mol. Sci., 23.10.3390/ijms23031045 ↗
57. New clinical application of three-dimensional-printed polycaprolactone/β-tricalcium phosphate scaffold as an alternative to allograft bone for limb-sparing surgery in a dog with distal radial osteosarcoma10.1292/jvms.18-0158 ↗
58. Pantarsal arthrodesis with a customised medial or lateral bone plate in 13 dogs10.1136/vr.154.6.165 ↗
59. Evaluation of healing in feline femoral defects filled with cancellous autograft, cancellous allograft or Bioglass10.1055/s-0038-1632947 ↗
60. Use of three-dimensionally printed β-tricalcium phosphate synthetic bone graft combined with recombinant human bone morphogenic protein-2 to treat a severe radial atrophic nonunion in a Yorkshire terrier10.1111/vsu.13476 ↗
61. Properties of interpenetrating polymer networks associating fibrin and silk fibroin networks obtained by a double enzymatic method10.1016/j.msec.2019.109931 ↗
62. Design, 3D printing, modeling, and in vitro testing of patient-specific endo-prostheses for limb-sparing surgery in dogs10.1016/j.medengphy.2019.07.005 ↗
63. Fedel, M. (2013). Blood compatibility of diamond-like carbon (DLC) coatings. Diamond-Based Materials for Biomedical Applications, Woodhead Publishing.10.1533/9780857093516.1.71 ↗
64. Diamond like carbon coatings for potential application in biological implants—A review10.1016/j.triboint.2012.09.006 ↗
65. Glial cell and fibroblast cytotoxicity study on plasma-deposited diamond-like carbon coatings10.1016/S0142-9612(03)00424-1 ↗
66. Diamond-like carbon coatings with zirconium-containing interlayers for orthopedic implants10.1016/j.jmbbm.2017.01.023 ↗
67. Load-Bearing Biomedical Applications of Diamond-Like Carbon Coatings–Current Status10.2174/1874325000802010043 ↗
68. Diamond-like carbon coatings in endoprosthetics (literature review)10.15674/0030-598720192102-111 ↗
69. A review of modified DLC coatings for biological applications10.1016/S0925-9635(03)00081-5 ↗
70. AbuAlia, M., Fullam, S., Cinotti, F., Manninen, N., and Wimmer, M.A. (2024). Titanium Nitride Coatings on CoCrMo and Ti6Al4V Alloys: Effects on Wear and Ion Release. Lubricants, 12.10.3390/lubricants12030096 ↗
71. Use of Ion Beam Enhanced Deposition (IBED) Titanium Nitride for Knee Arthroplasty Implants
72. Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: Residual stresses and fretting behavior10.1016/S0257-8972(00)00524-7 ↗
73. Comparison of Functional Properties of Thin Layers on Titanium and Cobalt Implant Alloys
74. Antibacterial surface design of biomedical titanium materials for orthopedic applications10.1016/j.jmst.2020.10.066 ↗
75. Bone Ingrowth Processes on Porous Metalic Implants10.4028/www.scientific.net/SSP.147-149.776 ↗
76. Investigation of Osseointegration of Porous Materials for Orthopedic Implants10.2478/v10147-011-0024-x ↗
77. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment10.1016/j.msec.2015.10.069 ↗
78. Influence of Porosity and Pore-Size Distribution in Ti6Al4 V Foam on Physicomechanical Properties, Osteogenesis, and Quantitative Validation of Bone Ingrowth by Micro-Computed Tomography10.1021/acsami.7b13960 ↗
79. Bone growth in rapid prototyped porous titanium implants
80. Optimize the pore size-pore distribution-pore geometry-porosity of 3D-printed porous tantalum to obtain optimal critical bone defect repair capability
81. Osseointegration of retrieved 3D-printed, off-the-shelf acetabular implants10.1302/2046-3758.107.BJR-2020-0462.R1 ↗
82. Effects of pore size and porosity of surface-modified porous titanium implants on bone tissue ingrowth10.1016/S1003-6326(19)65161-7 ↗
83. Powder Metal-Made Orthopedic Implants with Porous Surface for Fixation by Tissue Ingrowth10.1097/00003086-198306000-00007 ↗
84. Fabrication and Surface Modification of Biomaterials for Orthopedic Implant: A Review10.1142/S0218625X21410080 ↗
85. Zhu, Y., Zhou, D., Zan, X., Ye, Q., and Sheng, S. (2022). Engineering the surfaces of orthopedic implants with osteogenesis and antioxidants to enhance bone formation in vitro and in vivo. Colloids Surfaces B. Biointerfaces, 212.10.1016/j.colsurfb.2022.112319 ↗
86. Alontseva, D., Azamatov, B., Yantsen, Y.S., Voinarovych, S., and Nazenova, G. (2023). A Brief Review of Current Trends in the Additive Manufacturing of Orthopedic Implants with Thermal Plasma-Sprayed Coatings to Improve the Implant Surface Biocompatibility. Coatings, 13.10.3390/coatings13071175 ↗
87. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants10.1016/j.jmbbm.2018.07.019 ↗
88. Koju, N., Niraula, S., and Fotovvati, B. (2022). Additively Manufactured Porous Ti6Al4V for Bone Implants: A Review. Metals, 12.10.3390/met12040687 ↗
89. (2023). Standard Specification for Wrought Titanium-6Aluminum-4Vanadium Alloy for Surgical Implant Applications (UNS R56400) (Standard No. ASTM F1472).
90. Factors that impact the patellofemoral contact stress in the TKA: A review10.1186/s42836-023-00197-0 ↗
91. Adam, R., Moldovan, C., Tudorache, S., Hârșovescu, T., Orban, C., Pogărășteanu, M., and Rusu, E. (2023). Patellar Resurfacing in Total Knee Arthroplasty, a Never-Ending Controversy; Case Report and Literature Review. Diagnostics, 13.10.3390/diagnostics13030383 ↗
92. Trębacz, P., Frymus, J., Barteczko, A., Pawlik, M., Kurkowska, A., and Czopowicz, M. (2024). A 3D Printed Anatomically Pre-Contoured Plate for the Treatment of Y-T Humeral Condylar Fractures: A Feline Cadaveric Study. Animals, 14.10.3390/ani14040537 ↗