Simulation Models Predicting Pressure Distribution and Transmission underneath Blood Pressure Cuffs of Different Types
Source abstract
Abstract
Inflatable cuffs of different types are used for the measurement of blood pressure using the indirect method. It is crucial to find pressure distribution and transmission underneath different types of blood pressure measurement cuffs for estimating accurate values of blood pressure. In this study, three simulation models are developed mimicking blood pressure measurement through three cuffs constructed using fabrics that have dissimilar geometric and mechanical properties. Finite element analysis (FEA) is carried out to predict pressure distribution and transmission underneath these cuffs. For validation of these models, an arm simulator was developed. The models provide good agreement with the experimental results. The pressure distribution at the interface of the selected cuffs and arm is not identical.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ergonomics and Musculoskeletal Disorders · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
NED University of Engineering & Technology, Karachi, Pakistan; Prasad Potluri and Parthasarathi Mandal, The University of Manchester, UK
Stepping Hill Hospital, Stockport, UK
References (25)
Show source-provided references
1. 10.1109/10.23770010.1109/10.237700 ↗
2. 10.1007/BF0236822510.1007/BF02368225 ↗
3. Lan H. · In Proceedings, ASME International Mechanical Engineering Congress and Exposition · 2009 · 48630 · 621
4. 10.1023/A:101245261372010.1023/A:1012452613720 ↗
5. 10.1097/01.mbp.0000132428.71004.f310.1097/01.mbp.0000132428.71004.f3 ↗
6. 10.1115/1.279225810.1115/1.2792258 ↗
7. 10.1115/1.279225910.1115/1.2792259 ↗
8. Kim H.J., Lee H.C., Kim C.H., Kim Y.J., Jeon G.R. Blood flow and pressure in a brachial artery under cuff pressure. In IECON Proceedings, Industrial Electronics Conference, 2004, pp 2973–2977.
9. 10.1016/0021-9290(91)90322-E10.1016/0021-9290(91)90322-E ↗
10. 10.1097/00006534-198412000-0000110.1097/00006534-198412000-00001 ↗
11. Mann R · Journal of Burn Care & Rehabilitation · 1997 · 18 · 16010.1097/00004630-199703000-00012 ↗
12. 10.1177/00405175010710031410.1177/004051750107100314 ↗
13. 10.1007/3-540-28804-X_510.1007/3-540-28804-X_5 ↗
14. 10.1177/152808371663786810.1177/1528083716637868 ↗
15. ISO E. 1421/1998 Rubber or plastic coated fabric. Determination of tensile strength and elongation break, 1998.
16. BS EN 12127:1998 Determination of mass per unit area using small samples. British Standards Institution.
17. BS EN 1735:1997 Rubber- or plastics-coated fabrics. Determination of flexibility. British Standards Institution.
18. Williams B. · J. Hum. Hypertens. · 2004 · 18 · 1310.1038/sj.jhh.1001683 ↗
19. 10.1038/ajh.2009.13110.1038/ajh.2009.131 ↗
20. 10.1088/0143-0807/3/1/00210.1088/0143-0807/3/1/002 ↗
21. 10.1161/01.HYP.24.6.78610.1161/01.HYP.24.6.786 ↗
22. Biomechanical Engineering of Textiles and Clothing; Li Y., Dai D.X., Eds. Woodhead Publishing: Cambridge, UK, 2006.
23. 10.1038/ajh.2007.4510.1038/ajh.2007.45 ↗
24. 10.1097/00003246-198004000-0011510.1097/00003246-198004000-00115 ↗
25. 10.1291/hypres.24.35310.1291/hypres.24.353 ↗