Biocompatible Graphene Oxide-Based Glucose Biosensors
Source abstract
Abstract
This letter demonstrates that a novel, highly efficient enzyme electrode can be directly obtained using covalent attachment between carboxyl acid groups of graphene oxide sheets and amines of glucose oxidase. The resulting biosensor exhibits a broad linear range up to 28 mM x mm(-2) glucose with a sensitivity of 8.045 mA x cm(-2) x M(-1). The glucose oxidase-immobilized graphene oxide electrode also shows a reproducibility and a good storage stability, suggesting potentials for a wide range of practical applications. The biocompatibility of as-synthesized graphene oxide nanosheets with human cells, especially retinal pigment epithelium (RPE) cells, was investigated for the first time in the present work. Microporous graphene oxide exhibits good biocompatibility and has potential advantages with respect to cell attachment and proliferation, leading to opportunities for using graphene-based biosensors for the clinical diagnosis.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Graphene and Nanomaterials Applications · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Biomedical Engineering Academy, School of Ophthalmology & Optometry, Wenzhou Medical College, 270 Xueyuan Road, Wenzhou 325027, China
Department of Chemical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106
College of Chemistry and Chemical Engineering, Shaan-xi University of Science and Technology, Xi-an 710021, China
References (24)
Show source-provided references
1. Geim A. K. · Nat. Mater. · 2007 · 6 · 18310.1038/nmat1849 ↗
2. Stankovich S. · Nature · 2006 · 442 · 28210.1038/nature04969 ↗
3. Dikin D. A. · Nature · 2007 · 448 · 45710.1038/nature06016 ↗
4. Eda G. · Nat. Nanotechnol. · 2008 · 3 · 27010.1038/nnano.2008.83 ↗
5. Gomez-Navarro C · Nano Lett. · 2007 · 7 · 349910.1021/nl072090c ↗
6. Ramanathan T. · Nat. Nanotechnol. · 2008 · 3 · 32710.1038/nnano.2008.96 ↗
7. Mkhoyan K. A. · Nano Lett. · 2009 · 9 · 105810.1021/nl8034256 ↗
8. Li D. · Nat. Nanotechnol. · 2008 · 3 · 10110.1038/nnano.2007.451 ↗
9. Cosnier S. · Sens. Acuators, B · 1999 · 59 · 13410.1016/S0925-4005(99)00210-5 ↗
10. Kulys J. · Biosens. Bioelectron. · 1999 · 14 · 47310.1016/S0956-5663(99)00026-3 ↗
11. Horozova E. · Bioelectrochemistry · 2000 · 53 · 1110.1016/S0302-4598(00)00089-1 ↗
12. Netchiporouk L. I. · Anal. Chim. Acta · 1995 · 303 · 27510.1016/0003-2670(94)00538-W ↗
13. Nednoor P. · Bioconjugate Chem. · 2004 · 15 · 1210.1021/bc0341526 ↗
14. Poh W. C. · Langmuir · 2004 · 20 · 548410.1021/la0490947 ↗
15. Liu Y. · J. Electrochem. Soc. · 2008 · 155 · K10010.1149/1.2890417 ↗
16. Zhao W. · Biosens. Bioelectron. · 2006 · 22 · 64910.1016/j.bios.2006.01.026 ↗
17. Yang S. · Anal. Chem. · 2009 · 81 · 560310.1021/ac900136z ↗
18. Shan C. · Anal. Chem. · 2009 · 81 · 237810.1021/ac802193c ↗
19. Lu C. · Angew. Chem., Int. Ed. · 2009 · 48 · 478510.1002/anie.200901479 ↗
20. Lin Y. H. · Nano Lett. · 2004 · 4 · 19110.1021/nl0347233 ↗
21. Ramesha G. K. · J. Phys. Chem. C · 2009 · 113 · 798610.1021/jp811377n ↗
22. Situmorang M. · Biosens. Bioelectron. · 1998 · 13 · 95310.1016/S0956-5663(98)00033-5 ↗
23. Buttry D. A. · Chem. Rev. · 1992 · 92 · 135510.1021/cr00014a006 ↗
24. Reina A. · Nano Lett. · 2009 · 9 · 3010.1021/nl801827v ↗