article·2018-01-01Open access

Performance of cryogenically treated Cu and CuCrZr electrodes in an EDM process

Abdurrahman Cetin, Gültekin Cakir, Kubilay Aslantaş, Necati Uçak, A. CICEK

Abstract

In this study, the effects of cryogenic treatment (CT) on the performance of CuCrZr alloy and Cu electrodes in electro discharge machining (EDM) of AISI P20 tool steel were investigated experimentally. For this purpose, a group of electrodes were cryogenically treated at -140 C for 30 min and then tempered at 175 C for 1 h. The tool performance was evaluated in terms of electrode wear rate (EWR), material removal rate (MRR), and average surface roughness (Ra) of machined surfaces. The EDM tests were conducted at pulse currents of 4, 8, 12, and 16 A and pulse durations of 25 and 50 s. Experimental results showed that treated electrodes were less worn than the untreated ones and the Ra values of machined surfaces decreased when cryo-treated electrodes were used. Also, it was observed that pulse current is the most effective parameter in the EDM process. K e y w o r d s : electro discharge machining (EDM), cryogenic treatment, wear rate, copper alloy
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Machining and Optimization Techniques · Advanced Surface Polishing Techniques · Advanced machining processes and optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.