Study on the Part Unit Corrosion Evaluation for Automotive Lower Arm Using Electrochemical Cyclic Corrosion Test
Source abstract
Abstract
This research focused on the development of the part unit evaluation for an organic coated automotive lower arm using the electrochemical cyclic corrosion test (E-CCT). The E-CCT accelerates both the coating degradation and the perforation corrosion. The applied potential for the coating degradation was determined to be -500 mV SCE for anodic polarization and -900 mV SCE for cathodic polarization. The applied current for the perforation corrosion was equivalent to the applied anodic potential. The E-CCT was conducted for the duration of 8 cycles, which is considered to be equivalent to 4 years of driving. After the E-CCT, the coating degradation was evaluated by electrochemical impedance spectroscopy (EIS) measurements. Especially, the Z 100 mHz value (impedance value at a frequency of 100 mHz) of the part unit represented the amount of corrosion damage of the lower arm parts. The Z 100 mHz of the degraded coating area had a decisive effect on the Z 100 mHz value of the entire lower arm. This result was caused by electrochemical interaction between the non-degraded coating area and degraded coating area. The non-degraded coating area and the degraded coating area of the lower arm formed the parallel circuit which provides a satisfactory result.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Engineering Applied Research · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References