Formulation Design and Experiment Interpretation through Torque Measurements in High-Shear Wet Granulation
Source abstract
Abstract
High-shear wet granulation is commonly used in many industries such as in the pharmaceutical industry to convert fine cohesive powders into dense and round granules. The purpose of this work was to determine the effects of some important powder properties (crystalline or amorphous nature, hygroscopicity, solubility and particle size) and process variables (liquid addition rate, impeller speed) on the early stages of the granulation process and on drug distribution in granules obtained by high-shear wet granulation. The glass transition concept coupled with on-line impeller torque monitoring and measurements of the time evolution of the particle size distribution were used to study mixtures of pharmaceutical excipients and some common active ingredients. In particular a formulation map for estimating the minimum amount of liquid binder required to induce appreciable granule growth is presented, thus outlining a new method to considerably increase the predictability of the behaviour of different formulations on the basis of the physical properties of each single component. The description of the effects of the wetting condition on drug uniformity content in some formulations with hydrophobic active ingredients is given as well.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Granular flow and fluidized beds · Drug Solubulity and Delivery Systems · Microencapsulation and Drying Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
DIPIC, Department of Chemical Engineering, University of Padova
References (20)
Show source-provided references
1. 1) Litster, J.D. and Ennis, B. (2004): “The science and engineering of granulation processes”, Kluwer Academic Publisher.10.1007/978-94-017-0546-2 ↗
2. 2) Gokhale, R., Sun, Y., and Shukla, A.J. (2006): High-shear granulation. In: Parikh, D.M. (Ed.), “Handbook of Pharmaceutical Granulation Technology (2nd ed.)”, Taylor and Francis Group, New York.10.1201/9780849354953.ch7 ↗
3. 3) Leuenberger, H. and Bier, H.P. (1979): Bestimmung der optimalen Menge Granulierflüssigkeit durch Messung der elektrischen Leistungsaufnahme eines Planetenmischers, Acta Pharmaceutical Technology, 7suppl.. 1979, pp. 41–44.
4. 4) Bier, H.P., Leuenberger, H. and Sucker, H. (1979): Determination of the uncritical quantity of granulating liquid by power measurements on planetary mixers, Pharmaceutical Industry, 41, pp. 375–380.
5. 5) Imanidis, G. (1986): “Untersuchungen über die Agglomerierkinetik und die elektrische Leistungsaufnahme beim Granulierprozess im Schnellmischer”, Doctoral thesis, University of Basel, Switzerland,.
6. 6) Leuenberger, H., Bier, H.P. and Sucker, H. (1981): Determination of the liquid requirement for a conventional granulation process, German Chemical Engineering, 4, pp. 13–18.
7. 7) Leuenberger, H. (1982); Granulation, new techniques, Pharm. Acta Helvetica, 57 (3), pp. 72–82.
8. 8) Leuenberger, H. and Imanidis, G. (1984): Steuerung der Granulatherstellung im Mischer durch Leistungsmessung, Chemical Industry, XXXVI, pp.281–284.
9. 9) Faure, A., York, P. and Rowe, R.C. (2001): Process control and scale-up of pharmaceutical wet granulation processes: a review. Eur. J. Pharm. Biopharm., 52, pp. 269–277.10.1016/S0939-6411(01)00184-9 ↗
10. 10) Mort, P.R. (2005): Scale-up of binder agglomeration processes, Powder Technol., 150, pp. 86–103.10.1016/j.powtec.2004.11.025 ↗
11. 11) Cavinato, M., Bresciani, M., Machin, M., Bellazzi, G., Canu, P. and Santomaso, A.C. (2010): Formulation design for optimal high-shear wet granulation using on-line torque measurements, International Journal of Pharmaceutics, 387, pp. 48–55.10.1016/j.ijpharm.2009.11.032 ↗
12. 12) Palzer, S. (2010): The relation between material properties and supra-molecular structure of water-soluble food solids, Trends in Food Science & Technology, 21, pp.12–25.10.1016/j.tifs.2009.08.005 ↗
13. 13) Nguyen, T.H., Shen, W. and Hapgood, K. (2010): Effect of formulation hydrophobicity on drug distribution in wet granulation, Chemical Engineering Journal, 164, pp.330-339.10.1016/j.cej.2010.05.008 ↗
14. 14) Belohlav, Z., Brenkova, L., Hanika, J., Durdil, P., Rapek, P. and Tomasek, V. (2007): Effect of Drug Active Substance Particles on Wet Granulation Process, Chemical Engineering Research and Design, 85, pp.974–980.10.1205/cherd06205 ↗
15. 15) Litster, J.D., Hapgood, K.P., Michaels, J.N., Sims, A., Roberts, M., Kameneni, S.K. and Hsu, T. (2001): Liquid distribution in wet granulation: dimensionless spray flux, Powder Technology, 114, pp.29–32.10.1016/S0032-5910(00)00259-X ↗
16. 16) Fitzpatrick, J.J. (2007): Particle properties and the design of solid food particle processing operations, Food and Bioproducts Processing, 85, pp. 308–314.10.1205/fbp07056 ↗
17. 17) Palzer, S. (2005): The effect of glass transition on the desired and undesired agglomeration of amorphous food powders, Chemical Engineering Science, 60, pp. 3959–3968.10.1016/j.ces.2005.02.015 ↗
18. 18) Gordon, M. and Taylor, J.S. (1952): Ideal co-polymers and the second order transitions of synthetic rubbers. 1. Non-crystalline co-polymers, Journal of Applied Chemistry, 2, pp. 493–500.10.1002/jctb.5010020901 ↗
19. 19) Hancock, B.C. and Zografi, G. (1994): The relationship between the glass transition temperature and the water content of amorphous pharmaceutical solids, Pharmaceutical Research, 11, pp. 471–477.10.1023/A:1018941810744 ↗
20. 20) Hapgood, K.P., Litster, J.D. and Smith, R. (2003): Nucleation regime map for liquid bound granules, A.I.Ch.E. Journal, 49, pp.350–361.10.1002/aic.690490207 ↗