journal article·2011Open access

Use of Virtual Impactor (VI) Technology in Biological Aerosol Detection

Jim Ho

KONA Powder and Particle Journal· Volume 29· Issue 0

Abstract

Detecting biological threat aerosol is difficult in that a small cloud lasting only a few seconds at a point location may contain sufficient material to infect large numbers of exposed individuals. Clinical analytical methods require relative large amounts of the sample in liquid form to facilitate positive measurements. Biological agents may be fragile because of their lipid membranes that can be susceptible to harsh sample collection treatment. Damaged organisms may render subsequent analyses to be invalid. Virtual impaction (VI) sample collectors have been theorized to provide usable concentration rates yet are sufficiently gentle with the aerosol particles to preserve cellular viability. This review will discuss different implementations of VI technology and examine their merits. Outstanding issues will be outlined to aid future experimentation.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Indoor Air Quality and Microbial Exposure · Advanced Chemical Sensor Technologies · Air Quality Monitoring and Forecasting

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Biological Detection Section, Defence Research and Development Canada Suffield

References (57)

Show source-provided references
1. Abu-Lail, N. I. and T. A. Camesano (2003): Polysaccharide properties probed with atomic force microscopy. Journal of Microscopy, 212(3), pp. 217–238.10.1111/j.1365-2818.2003.01261.x ↗
2. Andre, P., S. Bilger, P. Remy, S. Bettinger and D. J. M. Vidon (2003): Effects of iron and oxygen species scavengers on Listeria spp. chemiluminescence. Biochemical and Biophysical Research Communications, 304(4), pp. 807–811.10.1016/S0006-291X(03)00671-5 ↗
3. Bakker, D. P., B. R. Postmus, H. J. Busscher and H. C. Van Der Mei (2004): Bacterial strains isolated from different niches can exhibit different patterns of adhesion to substrata. Applied and Environmental Microbiology, 70(6), pp. 3758–3760.10.1128/AEM.70.6.3758-3760.2004 ↗
4. Barrett, W.J., Miller, H. C. (1975): Investigation of Luminol and Collection Tape Components and the Effects of Airborne Interferents on the XM19 Detector. Quarterly progress rept. no. 2, SOUTHERN RESEARCH INST BIRMINGHAM AL, ADA007274.10.21236/ADA007274 ↗
5. Bergman, W., J. Shinn, R., Lochner, S. Sawyer, F. Milanovich and R. Mariella, Jr. (2005): High air flow, low pressure drop, bio-aerosol collector using a multi-slit virtual impactor. Journal of Aerosol Science, 36, pp. 619–638.10.1016/j.jaerosci.2004.12.010 ↗
6. Blatny, J., J. Ho, G. Skogan, E. Fykse, T. Aarskaug and V. Waagen (2010): Airborne Legionella bacteria from pulp waste treatment plant: aerosol particles characterized as aggregates and their potential hazard. Aerobiologia, 27(2), pp.147–162.10.1007/s10453-010-9184-9 ↗
7. Borthwick, K. A. J., T. E. Love, M. B. McDonnell and W. T. Coakley (2005): Improvement of immunodetection of bacterial spore antigen by ultrasonic cavitation. Analytical Chemistry, 77(22), pp. 7242–7245.10.1021/ac050576c ↗
8. Brenner, K. P., P. V. Scarpino and C. S. Clark (1988): Animal viruses, coliphages, and bacteria in aerosols and wastewater at a spray irrigation site. Appl Environ Microbiol., 54(2), pp. 409–15.10.1128/aem.54.2.409-415.1988 ↗
9. Cooper, C. W. (2010): High volume air sampling for viral aerosols: a comparative approach. AFIT/GES/ENV/10-M01, US Air Force Institute of Technology, Wright-Patterson Air Force Base, Ohio.
10. Druett, H. A. and K. R. May (1952): A wind tunnel for the study of airborne infections. J Hyg (Lond), 50(1), pp. 69–81.10.1017/S0022172400019434 ↗
11. Duncan, S., and Ho, J. (2008): Estimation of viable spores in Bacillus atrophaeus (BG) particles of 1 to 9 μm size range. Clean—Soil Air Water, 36, pp.584–592.10.1002/clen.200700178 ↗
12. Environmental Monitoring Systems, Laboratory, (1985): “Operating Procedure for the Sierra Series 244E Dichotomous sampler Equipped with the Andersen Model 246B PM10 Inle”, EMSL, Research Triangle Park, N.C.
13. Eubanks, L. M., T. J. Dickerson and K. D. Janda (2007): Technological advancements for the detection of and protection against biological and chemical warfare agents. Chem. Soc. Rev., 36(3), pp. 458–470.10.1039/b615227a ↗
14. Evans, B.T.N., Yee, E., Roy, G. and Ho, J. (1994): Remote Detection and Mapping of Bioaerosols. J. Aerosol Sci., 25, pp.1549–1566.10.1016/0021-8502(94)90224-0 ↗
15. Ferry, R. M., L. E. Farr and M. G. Hartman (1949): The Preparation and Measurement of the Concentration of Dilute Bacterial Aerosols. Chemical Reviews, 44(2), pp. 389–417.10.1021/cr60138a010 ↗
16. Fox, A. (2005): Mass spectrometry identification and biodetection, lessons learned and future developments in Identification of microorganisms by mass spectrometry, pp. 64–89. Ed C. L. Wilkens and J. O. Lay, John Wiley & Sons, Inc., Hoboken, N.J.10.1002/0471748641.ch2 ↗
17. Freiwald, A. and S. Sauer (2009): Phylogenetic classification and identification of bacteria by mass spectrometry. Nature Protocols, 4(5), pp. 732–742.10.1038/nprot.2009.37 ↗
18. Griest, W. H., M. B. Wise, K. J. Hart, S. A. Lammert, C. V. Thompson and A. A. Vass (2001): Biological agent detection and identification by the block II chemical biological mass spectrometer, Field Analytical Chemistry and Technology, 5(4), pp. 177–184.10.1002/fact.1019 ↗
19. Hairston, P., J. Ho , F.R. Quant (1997): Design of an instrument for Real-time Detection of Bioaerosols Using Simultaneous Measurement of Particle Aerodynamic Size and Intrinsic Fluorescence, J. Aerosol Sc., 28, pp. 471–482.10.1016/S0021-8502(96)00448-X ↗
20. Han, T., H. R. An and G. Mainelis (2010): Performance of an Electrostatic Precipitator with Superhydrophobic Surface when Collecting Airborne Bacteria. Aerosol Science and Technology, 44(5), pp. 339–348.10.1080/02786821003649352 ↗
21. Ho, J., Evans B.T.N. and Roy, G. (1990): “Laser Detection and Mapping of Biological Simulants. III. Dichotomous Sampler Measurements of Aerosol Concentrations as Related to LIDAR Signals (U)”. Suffield Report No. 532, (Unclassified).
22. Ho, J. (1991): “Characteristics of Simulant Aerosols for Study of the BCD Inlet Nozzle”. DRES Suffield Report No. 543, (Unclassified).
23. Ho, J., M. Spence and P. Hairston (1999): Measurement of Biological Aerosol with a Fluorescent Aerodynamic Particle Sizer (FLAPS): Correlation of Optical data with Biological Data, Aerobiologia, 15, pp. 281–291.10.1023/A:1007647522397 ↗
24. Ho, J., T. Tjarnhage, J. Burke and L. Stadnyk (2004): Background aerosol sampling: optical characteristics of live particles associated with thundershowers in Umea, Sweden in September 2003. Proceedings, the 8th International Symposium on Protection against Chemical and Biological Warfare Agents (including bioterrorism), Gothenburg, Sweden.
25. Ho, J. and S. Duncan (2005): Estimating aerosol hazards from an anthrax letter, J. Aerosol Sci., 36, pp. 701–709.10.1016/j.jaerosci.2004.11.019 ↗
26. Ho, J., M. Spence and S. Duncan (2005): An approach towards characterizing a reference sampler for culturable biological particle measurement, J. Aerosol Sci., 36, pp. 557–573.10.1016/j.jaerosci.2004.11.020 ↗
27. Ho, J., N. Stanley and T. Kuehn (2010): Feasibility of using real-time optical methods for detecting the presence of viable bacteria aerosols at low concentrations in clean room environments. Aerobiologia, 27(2), pp.163–172.10.1007/s10453-010-9185-8 ↗
28. Huffman, J. A., B. Treutlein and U. Poschl (2010): Fluorescent biological aerosol particle concentrations and size distributions measured with an Ultraviolet Aerodynamic Particle Sizer (UV-APS) in Central Europe. Atmospheric Chemistry and Physics, 10(7), pp. 3215–3233.10.5194/acp-10-3215-2010 ↗
29. Jones, A. M. and R. M. Harrison (2004): The effects of meteorological factors on atmospheric bioaerosol concentrations-a review, The Science of the Total Environment, 326(1–3), pp. 151–80.10.1016/j.scitotenv.2003.11.021 ↗
30. Kesavan, J., and Doherty R. W. (2001): Characterization of the SCP 1021 Aerosol Sampler. Edgewood Chemical Biological Center Report ECBC-TR-211, Aberdeen Proving Ground, MD. National Technical Information Service, 5285, Port Royal Road, Springfield, VA 22161, report ADA397460, www.ntis.gov.10.21236/ADA397460 ↗
31. Kim, M. G., Y. H. Kim, H. L. Kim, C. W. Park, Y. H. Joe, J. Hwang and Y. J. Kim (2010): Wall loss reduction technique using an electrodynamic disturbance for airborne particle processing chip applications, Journal of Micromechanics and Microengineering, 20(3), pp. 1–12.10.1088/0960-1317/20/3/035034 ↗
32. Laflamme, C., Verreault, D., Lavigne, S., Trudel, L., Ho, J., Duchaine, C. (2005): Autofluorescence as a viability marker for detection of bacterial spores, Frontiers in Bioscience, 10, pp. 1647–1653.10.2741/1648 ↗
33. Lai, C. Y. and C. C. Chen (2000): Performance characteristics of PM10 samplers under calm air conditions. J Air Waste Manag Assoc., 50(4), pp.578–87.10.1080/10473289.2000.10464029 ↗
34. Lindsley, W. G., F. M. Blachere, R. E. Thewlis, A. Vishnu, K. A. Davis, G. Cao, J. E. Palmer, K. E. Clark, M. A. Fisher, R. Khakoo and D. H. Beezhold (2010): Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs. Plos One 5(11), e15100.10.1371/journal.pone.0015100 ↗
35. Longchamp, P. and T. Leighton (1999): Molecular recognition specificity of Bacillus anthracis spore antibodies, Journal of Applied Microbiology, 87, pp. 246–249.10.1046/j.1365-2672.1999.00879.x ↗
36. Loo, B. W. and C. P. Cork (1988): Development of High-Efficiency Virtual Impactors. Aerosol Science and Technology, 9(3), pp. 167–176.10.1080/02786828808959205 ↗
37. Mainelis, G., D. Masquelier, A. Makarewicz and J. Dzenitis (2005): Performance characteristics of the aerosol collectors of the autonomous pathogen detection system (APDS), Aerosol Science and Technology, 39(5), pp. 461–471.10.1080/027868290960382 ↗
38. Marple, V. A. (1970): “A Fundamental Study of Inertial Impactors,” PhD Thesis, Mechanical Engineering Department, University of Minnesota, Particle Technology Laboratory Publ. No. 144.10.2172/4095434 ↗
39. Marple, V. A. and C. M. Chien (1980): Virtual impactors: A theoretical study, Environmental Science and Technology, 14(8), pp. 976–985.10.1021/es60168a019 ↗
40. Marple, V. A. (2004): History of Impactors - The first 110 years, Aerosol Science and Technology, 38(3), pp. 247–292.10.1080/02786820490424347 ↗
41. Miller, C. A. and P. O. Vogelhut (1978): Chemiluminescent detection of bacteria: experimental and theoretical limits, Appl Environ Microbiol., 35(4), pp. 813–6.10.1128/aem.35.4.813-816.1978 ↗
42. Neufeld, H. A., C. J. Conklin and R. D. Towner (1965): Chemiluminescence of Luminol in Presence of Hematin Compounds, Analytical Biochemistry, 12(2), pp. 303–309.10.1016/0003-2697(65)90095-3 ↗
43. Park, D., Y. H. Kim, C. W. Park, J. Hwang and Y. J. Kim (2009): New bio-aerosol collector using a micromachined virtual impactor, Journal of Aerosol Science 40(5), pp. 415–422.10.1016/j.jaerosci.2008.12.007 ↗
44. Phillips, A.P. and K.L. Martin (1988): Investigation of spore surface antigens in the genus Bacillus by the use of polyclonal antibodies in immunofluorescence tests, Journal of Applied Bacteriology, 64(1), pp. 47–55.10.1111/j.1365-2672.1988.tb02428.x ↗
45. Prod'hom, G., A. Bizzini, C. Durussel, J. Bille and G. Greub (2010): Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Direct Bacterial Identification from Positive Blood Culture Pellets. Journal of Clinical Microbiology, 48(4), pp. 1481–1483.10.1128/JCM.01780-09 ↗
46. Quinlan, J.J. and P.M. Foegeding (1997): Monoclonal antibodies for use in detection of Bacillus and Clostridium spores, Applied and Environmental Microbiology, 63, pp. 482–487.10.1128/aem.63.2.482-487.1997 ↗
47. Riedel, S. (2004): Biological warfare and bioterrorism: a historical review, Proc (Bayl Univ Med Cent), 17(4), pp. 400–406.10.1080/08998280.2004.11928002 ↗
48. Rostker, B. (2000): Close-out report biological warfare investigation, Special Assistant for Gulf War Illnesses, Department of Defense declassified by CBDCOM Security Class Review Board 20 Jan 1998. http://www.gulflink.osd.mil/bw/index.html.
49. Schofield, L., Ho J., Kournikakis, B. and Booth T. (2005): Avian influenza aerosol sampling campaign in the British Columbia Fraser valley April 9–19 2004, Sampling of rare biological events, DRDC Suffield TM 2005-032.
50. Sioutas, C., P. Koutrakis and R. M. Burton (1994): Development of a Low Cutpoint Slit Virtual Impactor for Sampling Ambient Fine Particles, Journal of Aerosol Science, 25(7), pp. 1321–1330.10.1016/0021-8502(94)90128-7 ↗
51. Smart, J.K. (2005): History of Chemical and Biological Detectors, Alarms, and Warning Systems” Chemical and Biological Defense Information Analysis Center, Vol. 6, No. 4. Aberdeen Proving Ground, MD 21010-5424. http://www.wood.army.mil/ccmuseum/ccmuseum/Library/Detectors_History.pdf.
52. Sotnikov, G.G. (1970): Detection of iron-porphyrin proteins with a biochemiluminescent method in search of extraterrestrial life, Life Sci Space Res., 8, pp. 90–8.
53. Tellier, R. (2006): Review of aerosol transmission of influenza A virus, Emerging Infectious Diseases, 12(11), pp. 1657–1662.10.3201/eid1211.060426 ↗
54. Thomas, R. J., D. Webber, W. Sellors, A. Collinge, A. Frost, A. J. Stagg, S. C. Bailey, P. N. Jayasekera, R. R. Taylor, S. Eley and R. W. Titball (2008): Characterization and deposition of respirable large- and small-particle bioaerosols, Applied and Environmental Microbiology, 74(20), pp. 6437–6443.10.1128/AEM.01194-08 ↗
55. Verreault, D., S. Moineau and C. Duchaine (2008) : Methods for sampling of airborne viruses, Microbiol Mol Biol Rev., 72(3), pp. 413–44.10.1128/MMBR.00002-08 ↗
56. Vong, L., A. Laes and S. Blain (2007): Determination of iron-porphyrin-like complexes at nanomolar levels in seawater, Analytica Chimica Acta, 588(2), pp. 237–244.10.1016/j.aca.2007.02.007 ↗
57. Yoon, K. Y., C. W. Park, J. H. Byeon and J. Hwang (2010): Design and Application of an Inertial Impactor in Combination with an ATP Bioluminescence Detector for In Situ Rapid Estimation of the Efficacies of Air Controlling Devices on Removal of Bioaerosols, Environmental Science & Technology, 44(5), pp. 1742–1746.10.1021/es903437z ↗