Development of a Particulate Solids Thermal Mass Flowmeter
Source abstract
Abstract
An ideal mass flow meter should have the following properties: it should be non-invasive so as not to disrupt the flow profile; it should be easily installed on the conveying line to provide on-line and continuous measurements; it should be able to provide an accurate indication of the mass flow rate regardless of the orientation of the measurement section, inhomogeneities in the solids’ distribution, irregularities in the velocity profile, or variations in particle size, moisture content and material properties.A mass flow meter as described in this paper has been developed which uses a thermal method, a direct, noninvasive approach to measuring the mass flow rate. The thermal method uses the principle of heat transfer to solid particles in a flowing fluid to determine the mass flow rate of particles. The mass flow meter is designed such that temperature sensors are located at two ends of a heated pipe section. In the experiments carried out, measurements of gas and solids’ temperature were taken and used to calculate the heat transferred to the solids. The mass flow rate obtained using the thermal mass flow meter was compared to that using load cells. The results obtained are analysed and presented in this paper.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Flow Measurement and Analysis · Electrical and Bioimpedance Tomography · Advanced Sensor Technologies Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Glasgow Caledonian University
References (25)
Show source-provided references
1. Aihara T., Yamamoto K., Narusawa K., Haraguchi T., Ukaku M., Lasek A., Feuillenois F., Experimental study on heat transfer of thermally developing and developed, turbulent, horizontal pipe flow of dilute air-solids suspensions, Heat and Mass Transfer, 33 (1997) 109–120.10.1007/s002310050167 ↗
2. Arakaki C., Ghaderi A., Datta B.K., Lie B., Non-intrusive mass flow measurements in pneumatic transport, CHoPS-05, Proceedings, 5th International Conference for Conveying and Handling of Particulate Solids, Sorrento, Italy, 2006.
3. Arko A., Waterfall R.C., Beck M.S., Dyakowski T., Sutcliffe P., Byars M., Development of Electrical Capacitance Tomography for solids mass flow measurement and control of pneumatic conveying systems, Proceedings, 1st World Congress on Industrial Process Tomography, Buxton, Greater Manchester, 1999.
4. Beck M.S., Green R.G., Thorn R., Non-intrusive measurement of solids mass flow in Pneumatic Conveying, Journal of Physics E: Scientific Instruments, 20 (1987) 835–840.10.1088/0022-3735/20/7/002 ↗
5. Carter R.M., Yan Y., Cameron S.D., On-line measurement of particle size distribution and mass flow rate of particles in a pneumatic suspension using combined imaging and electrostatic sensors, Journal of Flow, Measurement & Instrumentation, 16 (2005) 309–314.10.1016/j.flowmeasinst.2005.03.005 ↗
6. Farber L., Depew C.A., Heat transfer effects to gas-solids mixtures using solid spherical particles of uniform size, Industrial & Engineering Chemistry Fundamentals, 2 (1963) 130–135.10.1021/i160006a008 ↗
7. Farber L., Morley M.J., Heat transfer to flowing gas-solids mixtures in a circular tube, Industrial & Engineering Chemistry, 49 (1957) 1143–1150.10.1021/ie50571a038 ↗
8. Han I.Y., Kim D-K., Kim S.J., Study on the transient characteristics of the sensor tube of a thermal mass flow meter, Int’l Journal of Heat & Mass Transfer, 48 (2005) 2583–2592.10.1016/j.ijheatmasstransfer.2005.01.021 ↗
9. Holman J.P., Heat Transfer, tenth ed., McGraw-Hill Inc., 2010.
10. Hrach D., Fuchs A., Zangl H., Capacitive flow meter for gas-solids flow applications exploiting spatial frequency, Proceedings, IEEE Sensors Application Symposium, Atlanta GA, 2008.10.1109/SAS13374.2008.4472937 ↗
11. Huang Z., Wang B., Li H., An intelligent measurement system for powder flow rate measurement in pneumatic conveying system, Proceedings, IEEE Instrum. & Meas. Tech. Conference, Budapest, Hungary, 2001.
12. Kato M., Pugh J.R., McGlinchey D., The influence of windows on infra-red temperature measurements for solids’ mass flow rate determination, Journal of Flow, Measurement & Instrumentation, 27 (2012) 99–103.10.1016/j.flowmeasinst.2012.04.012 ↗
13. Kim D-K., Han I.Y., Kim S.J., Study on the steady-state characteristics of the sensor tube of a thermal mass flow meter, Int’l Journal of Heat & Mass Transfer, 50 (2007) 1206– 1211.10.1016/j.ijheatmasstransfer.2006.08.021 ↗
14. McGlinchey D., Pugh J.R., Knight E.A., Kumaraperumal A., Samaila I., Ibn Mohammed T., Operation of a novel Industrial Scale Thermal Solids Mass Flow meter, Bulk Europe 2010 & IMechE Symposium New Frontiers in Bulk Materials Handling, Glasgow, Scotland, 2010.
15. McGlinchey D., Pugh J., Knight L., Cowell A., Zheng L., Liu Q., Analysis and measurements from a prototype in-line thermal solids mass flow meter in an industrial scale dilute phase pneumatic conveying system, Particulate Science & Technology, 31 (2013) 271–276.10.1080/02726351.2012.725122 ↗
16. Moriyama T., Non-intrusive measuring methods on mass flow rate for moved bed gravity flow of the new plants, Proceedings, IEEE Instrum. & Meas. Tech. Conference, Brussels, Belgium, 1996.
17. Rajan K.S., Srivastava S.N., Pitchumani B., Dhasandhan K., Experimental study of thermal effectiveness in pneumatic conveying heat exchanger, Applied Thermal Engineering, 28 (2008) 1932–1941.10.1016/j.applthermaleng.2007.12.004 ↗
18. Rajan K.S., Srivastava S.N., Pitchumani B., Surendivan V., Thermal conductance of pneumatic conveying preheater for air-gypsum and air-sand heat transfer, Int’l Journal of Thermal Sciences, 49 (2010) 182–186.10.1016/j.ijthermalsci.2009.07.001 ↗
19. Viswanathan M., Kandaswamy A., Sreekala S.K., Sajna K.V., Development, modelling and certain investigations on thermal mass flow meters, Journal of Flow, Measurement & Instrumentation, 12 (2002a) 353–360.10.1016/S0955-5986(02)00002-X ↗
20. Viswanathan M., Rajesh R., Kandaswamy A., Design and development of thermal mass flow meters for high pressure applications, Journal of Flow, Measurement & Instrumentation, 13 (2002b) 95–102.10.1016/S0955-5986(02)00021-3 ↗
21. Yan Y., Mass flow measurement of bulk solids in pneumatic pipelines, Measurement, Science & Technology, 7 (1996) 1687–1706.10.1088/0957-0233/7/12/002 ↗
22. Zheng Y., Li Y., Liu Q., Measurement of mass flow rate of particulate solids in gravity chute conveyor based on laser sensing array, Optics & Laser Tech., 39 (2007) 298–305.10.1016/j.optlastec.2005.07.012 ↗
23. Zheng Y., Pugh J.R., McGlinchey D., Ansell R.O., Simulation and experimental study of gas-to-particle heat transfer for non-invasive mass flow measurement, Measurement, 41 (2008) 446–454.10.1016/j.measurement.2007.01.007 ↗
24. Zheng Y., Liu Q., Review of certain key issues in indirect measurements of the mass flow rate of solids in pneumatic conveying pipelines, Measurement, 43 (2010) 727–734.10.1016/j.measurement.2010.02.002 ↗
25. Zheng Y., Liu Q., Review of techniques for the mass flow rate measurement of pneumatically conveyed solids, Measurement, 44 (2011) 589–604.10.1016/j.measurement.2011.01.013 ↗