journal article·2013Open access

A Comparison of Aerosol Performance Using Standardized Entrainment Tubes vs. Dry Powder Inhaler Devices

Zhen Xu, Anthony J Hickey

KONA Powder and Particle Journal· Volume 30· Issue 0

Abstract

This paper reviews scientific understandings relevant to the dry powder inhaler (DPI) development including turbulent airflow characteristics in the inhaler, microparticle entrainment and deaggregation within the airflow and device. Using standardized entrainment tubes (SETs) and powder aerosol deaggregation equation (PADE), the aerosol performance profile in a shear stress range defined by SETs can be predicted. However, such predictions are based on the hypothesis that the shear stresses characterized from SETs are readily translatable to those of the DPIs’. Two selected model DPIs (Rotahaler and Aerolizer) with either gelatin or HPMC capsules were used to evaluate the FPF at the DPI shear stresses. The performance result using DPIs was close to the predicted FPF using SETs and PADE method. The application of SETs and PADE method can be used for performance prediction of these DPIs.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Inhalation and Respiratory Drug Delivery · Particle Dynamics in Fluid Flows · Aerosol Filtration and Electrostatic Precipitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Division of Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina

Research Triangle Institute

References (32)

Show source-provided references
1. 1) Clark, A. R. (1995): Medical aerosol inhalers: past, present, and future, Aerosol Sci. Technol., Vol.22, pp.374–391.10.1080/02786829408959755 ↗
2. 2) Louey, M. D., VanOort, M., and Hickey, A. J. (2006): Standardized entrainment tubes for the evaluation of pharmaceutical dry powder dispersion, J. Aerosol Sci., Vol.37, pp.1520–1533.10.1016/j.jaerosci.2006.04.002 ↗
3. 3) Xu, Z., Mansour, H. M., Mulder, T., McLean, R., Langridge, J., and Hickey, A. J. (2010): Dry powder aerosols generated by standardized entrainment tubes from drug blends with lactose monohydrate: 1. Albuterol sulfate and disodium cromoglycate, J. Pharm. Sci., Vol.99, pp.3398–3414.10.1002/jps.22107 ↗
4. 4) Xu, Z., Mansour, H. M., Mulder, T., McLean, R., Langridge, J., and Hickey, A. J. (2010): Dry powder aerosols generated by standardized entrainment tubes from drug blends with lactose monohydrate: 2. Ipratropium bromide monohydrate and fluticasone propionate, J. Pharm. Sci., Vol.99, pp.3415–3429.10.1002/jps.22100 ↗
5. 5) Xu, Z., Mansour, H. M., Mulder, T., McLean, R., Langridge, J., and Hickey, A. J. (2010): Heterogeneous particle deaggregation and its implication for therapeutic aerosol performance, J. Pharm. Sci., Vol.99, pp.3442–3461.10.1002/jps.22057 ↗
6. 6) Mansour, H. M., Xu, Z., and Hickey, A. J. (2010): Dry powder aerosols generated by standardized entrainment tubes from alternative sugar blends: 3. Trehalose dihydrate and D-mannitol carriers, J. Pharm. Sci., Vol.99, pp.3430–3441.10.1002/jps.22101 ↗
7. 7) Xu, Z., Mansour, H. M., and Hickey, A. J. (2011): Particle interactions in dry powder inhaler unit processes: a review, J. Adhesion Sci. Technol., Vol.25, pp.451–482.10.1163/016942410X525669 ↗
8. 8) Hickey, A. J. and Ganderton, D. (2010): “Fluid flow”, Pharmaceutical Process Engineering, 2nd edition, Informa Healthcare USA, pp.4–30.
9. 9) Dunbar, C. A., Hickey, A. J., and Holzner, P. (1998): Dispersion and characterization of pharmaceutical dry powder aerosols, KONA Powder and Particle Journal, No.16, pp.7–45.10.14356/kona.1998007 ↗
10. 10) Pope, S. B. (2000): “Wall flows”, Turbulent Flows, Cambridge University Press, Cambridge, UK, p.264–332.10.1017/CBO9781316179475.009 ↗
11. 11) Shekunov, B. Y., Feeley, J. C., Chow, A. H., Tong, H. H., and York, P. (2003): Aerosolization behavior of micronized and supercritically-processed powders, J. Aerosol Sci., Vol.34, pp.553–568.10.1016/S0021-8502(03)00022-3 ↗
12. 12) Clark, A. R. and Hollingsworth, A. M. (1993): The relationship between powder inhaler resistance and peak inspiratory conditions in healthy volunteers - implications for in vitro testing, J Aerosol Med., Vol.6, pp.99–110.10.1089/jam.1993.6.99 ↗
13. 13) Mendes, P. J., Pinto, J. F., and Sousa, J. M. M. (2007): A non-dimensional functional relationship for the fine particle fraction produced by dry powder inhales, J. Aerosol Sci., Vol.38, pp.612–624.10.1016/j.jaerosci.2007.04.001 ↗
14. 14) de Boer, A. H., Winter, H. M. I., and Lerk, C. F. (1996): Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers part 1. inhalation characteristics, work of breathing and volunteers’ preference in dependence of the inhaler resistance, Int. J. Pharm., Vol.130, pp.231–244.10.1016/0378-5173(95)04326-8 ↗
15. 15) Wong, W., Fletcher, D. F., Traini, D., Chan, H. K., Crapper, J., and Young, P. M. (2010): Particle aerosolisation and break-up in dry powder inhalers 1: evaluation and modelling of venturi effects for agglomerated systems, Pharm. Res., Vol.27, pp.1367–1376.10.1007/s11095-010-0128-4 ↗
16. 16) Calvert, G., Ghadiri, M. and Tweedie, R. (2009): Aerodynamic dispersion of cohesive powders: a review of understanding and technology, Adv. Powder Tech., Vol.20, pp.4–16.10.1016/j.apt.2008.09.001 ↗
17. 17) Coates, M. S., Tang, P., Chan, H. K., Fletcher, D. F., and Raper, J. A. (2009): “Characterization of pharmaceutical aerosols and dry powder inhalers for pulmonary drug delivery”, Particulate Systems in Nano- and Biotechnologies”, eds: Sigmund, W., El-Shall, H., Shah, D. O., Moudgil, B. M., CRC Press Taylor & Francis Group, p.193–222.10.1201/9781420007534-9 ↗
18. 18) Ziskind, G., Fichman, M., and Gutfinger, C. (1995): Resuspension of particulates from surfaces to turbulent flows - review and analyss, J. Aerosol Sci., Vol.26, pp.613–644.10.1016/0021-8502(94)00139-P ↗
19. 19) Ziskind, G., Fichman, M., and Gutfinger, C. (1997): Adhesion moment model for estimating particle detachment from a surface, J. Aerosol Sci., Vol.28, pp.623–634.10.1016/S0021-8502(96)00460-0 ↗
20. 20) Wang, H. C. (1990): Effects of inception motion on particle detachment from surfaces, Aerosol Sci. Tech., Vol.13, pp.386–393.10.1080/02786829008959453 ↗
21. 21) Ibrahim, A. H., Dunn, P. F., and Brach, R. M. (2003): Microparticle detachment from surfaces exposed to turbulent air flow: controlled experiments and modeling, J. Aerosol Sci., Vol.34, pp.765–782.10.1016/S0021-8502(03)00031-4 ↗
22. 22) Gradon, L. (2009): Resuspension of particles from surfaces: technological, environmental and pharmaceutical aspects, Adv. Powder Tech., Vol.20, pp.17–28.10.1016/j.apt.2008.10.009 ↗
23. 23) Reeks, M. W., Reed, J., and Hall, D. (1998): On the resuspension of gas-borne particles in recirculating turbulent flow, J. Phys. D: Appl. Phys., Vol.21, pp.574–589.10.1088/0022-3727/21/4/006 ↗
24. 24) Wen, H. Y. and Kasper, G. (1989): On the kinetics of particle reentrainment from surfaces, J. Aerosol Sci., Vol.20, pp.483–498.10.1016/0021-8502(89)90082-7 ↗
25. 25) Pope, S. B. (2000): “Free shear flows”, Turbulent Flows, Cambridge University Press, Cambridge, UK, p.158–161.10.1017/CBO9780511840531 ↗
26. 26) Coates, M. S., Fletcher, D. F., Chan, H. K., and Raper, J. A. (2004): Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length, J. Pharm. Sci., Vol.93, pp.2863–2876.10.1002/jps.20201 ↗
27. 27) Richards, R. and Saunders, M. (1993): Need for a comparative performance standard for dry powder inhalers, Thorax., Vol.48, pp.1186–1187.10.1136/thx.48.11.1186 ↗
28. 28) Chew, N. Y., Bagster, D. F., and Chan, H. K. (2000): Effect of particle size, air flow and inhaler device on the aerosolisation of disodium cromoglycate powders, Int. J. Pharm., Vol.206, pp.75–83.10.1016/S0378-5173(00)00516-0 ↗
29. 29) Coates, M. S., Fletcher, D. F., Chan, H. K., and Raper, J. A. (2005): The role of capsule on the performance of a dry powder inhaler using computational and experimental analyses, Pharm. Res., Vol.22, pp.923–932.10.1007/s11095-005-4587-y ↗
30. 30) Coates, M. S., Chan, H. K., Fletcher, D. F., and Chiou, H. (2007): Influence of mouthpiece geometry on the aerosol delivery performance of a dry powder inhaler, Pharm. Res., Vol.24, pp.1450–1456.10.1007/s11095-007-9262-z ↗
31. 31) Weuthen, T., Roeder, S., Brand, P., Mullinger, B., and Scheuch, G. (2002): In vitro testing of two formoterol dry powder inhalers at different flow rats, J. Aerosol Med., Vol.15, pp.297–303.10.1089/089426802760292636 ↗
32. 32) Voss, A., Finlay, W. H. (2002): Deagglomeration of dry powder pharmaceutical aerosols, Int. J. Pharm., Vol.248, pp.39–50.10.1016/S0378-5173(02)00319-8 ↗