journal article·2020-01-10Open access

Analysis of Industry-Related Flows by Optical Coherence Tomography—A Review

Antti I. Koponen, Sanna Haavisto

KONA Powder and Particle Journal· Volume 37· Issue 0

Abstract

Optical Coherence Tomography (OCT) is a light-based imaging method capable of simultaneously capturing the internal structure and motion (1D, 2D or 3D) of various opaque and turbid materials with a micron-level spatial resolution. Depending on the OCT technology, axial scanning rates can vary in a range of tens to hundreds of kHz. The actual imaging depth significantly depends on the optical properties of the material and can vary from micrometers to a few millimeters. \n\nFrom the viewpoint of industrial applications, OCT technology is very appealing. Due to its resolution, speed, and ability to deal with opaque materials, it fills an apparent gap in available measurement methods. Nonetheless, OCT has not to date seen widespread growth in the industrial field. This has been at least partly due to a lack of commercial devices compact and flexible enough to adapt to industrial needs. The recent emergence of more generic commercial OCT devices has considerably lowered the threshold for adapting the technique. \n\nThe utilization of OCT for structural analysis, also outside the medical field, has been thoroughly discussed in scientific literature. Therefore, in this paper, we will mainly concentrate on applications of OCT that also utilize its capability of performing velocity measurements. The emphasis will be on industrially motivated problems such as rheology, microfluidics, fouling and turbulence.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Optical Coherence Tomography Applications · Photoacoustic and Ultrasonic Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

VTT Technical Research Centre of Finland Ltd., Finland

Spinnova Ltd., Finland

Funding

Research Council of Finland · Horizon 2020-European External Action Service

References (100+)

Show source-provided references
1. Ahn Y.-C., Jung W., Chen Z., Optical sectioning for microfluidics: secondary flow and mixing in a meandering microchannel, Lab Chip, 8: 1 (2008) 125–133.10.1039/B713626A ↗
2. Aigner M., Salaberger D., Buchsbaum A., Heise B., Schausberger S., Köpplmayr T., Lang C., Leitner M., Stifter D., Burzic I., Miethlinger J., The influence of glass fibers on elongational viscosity studied by means of optical coherence tomography and X-ray computed tomography, AIP Conference Proceedings, 1593 (2014) 217–221.10.1063/1.4873767 ↗
3. Alibhai A.Y., Or C., Witkin A.J., Swept source optical coherence tomography: a review, Current Ophthalmology Reports, 6: 1 (2018) 7–16. DOI: 10.1007/s40135-018-0158-310.1007/s40135-018-0158-3 ↗
4. Awaja F., Arhatari B., Wiesauer K., Leiss E., Stifter D., An investigation of the accelerated thermal degradation of different epoxy resin composites using X-ray microcomputed tomography and optical coherence tomography, Polymer Degradation and Stability, 94: 10 (2009) 1814–1824.10.1016/j.polymdegradstab.2009.06.005 ↗
5. Barnes H., A review of the slip (wall depletion) of polymer solutions, emulsions and particle suspensions in viscometers: its cause, character, and cure, J. Non-Newtonian Fluid Mech., 56: 3 (1995) 221–251.10.1016/0377-0257(94)01282-M ↗
6. Barrat J., Hansen J., Basic Concepts for Simple and Complex Liquids, Cambridge University Press, Cambridge, 2003.10.1017/CBO9780511606533 ↗
7. Batchelor G.K., An Introduction to Fluid Dynamics, Cambridge University Press, Cambridge, 2000.10.1017/CBO9780511800955 ↗
8. Bhattacharjee N., Urrios A., Kanga S., Folch A., The upcoming 3D-printing revolution in microfluidics, Lab Chip, 16: 10 (2016) 1711–1948.10.1039/C6LC00163G ↗
9. Blackmon R., Rupninder S., Chapman B., Casbas-Hernandez P., Tracy J., Troester M., Oldenburg A., Imaging extracellular matrix remodeling in vitro by diffusion-sensitive optical coherence tomography, Biophysical Journal, 110: 8 (2016) 1858–1868.10.1016/j.bpj.2016.03.014 ↗
10. Blauert F., Horn H., Wagner M., Time-resolved biofilm deformation measurements using optical coherence tomography, Biotechnol. Bioeng., 112: 9 (2015) 1893–1905.10.1002/bit.25590 ↗
11. Boer de J., Hitzenberger C., Yasuno Y., Polarization sensitive optical coherence tomography—a review, Biomed. Opt. Express, 8: 3 (2017) 1838–1873.10.1364/BOE.8.001838 ↗
12. Bonesi M., Churmakov D., Ritchie L., Meglinski I., Turbulence monitoring with Doppler Optical Coherence Tomography, Laser Phys. Lett., 4: 4 (2007) 304–307.10.1002/lapl.200610098 ↗
13. Bonesi M., Proskurin S., and Meglinski I., Imaging of subcutaneous blood vessels and flow velocity profiles by optical coherence tomography, Laser Phys., 20: 4 (2010) 891–899.10.1134/S1054660X10070029 ↗
14. Bott T., Fouling of Heat Exchangers, 1st ed., Elsevier, Amsterdam, 1995.10.1016/B978-044482186-7/50003-8 ↗
15. Bukowska D., Derzsi L., Tamborski S., Szkulmowski M., Garstecki P., Wojtkowski M., Assessment of the flow velocity of blood cells in a microfluidic device using joint spectral and time domain optical coherence tomography, Optics Express, 21: 20 (2013) 24025–24038.10.1364/OE.21.024025 ↗
16. de Carlo T., Romano A., Waheed N., Duker J., A review of optical coherence tomography angiography (OCTA), International Journal of Retina and Vitreous, 1 (2015) 5(pp15). DOI: 10.1186/s40942-015-0005-810.1186/s40942-015-0005-8 ↗
17. Chaouki J., Larachi F., Dudukovic M., Noninvasive tomographic and velocimetric monitoring of multiphase flows, Ind. Eng. Chem. Res., 36: 11 (1997) 4476–4503.10.1021/ie970210t ↗
18. Chen C., Menon P., Kowalski W., Pekkan K., Time-resolved OCT-μPIV: a new microscopic PIV technique for noninvasive depth-resolved pulsatile flow profile acquisition, Exp. Fluids, 54 (2013) 1426 (pp9).10.1007/s00348-013-1466-x ↗
19. Chen C., Cheng K., Jakubovic R., Jivraj J., Ramjist J., Deorajh R., Gao W., Barnes E., Chin L., Yang V., High speed, wide velocity dynamic range Doppler optical coherence tomography (Part V): Optimal utilization of multi-beam scanning for Doppler and speckle variance microvascular imaging, Optics Express, 25: 7 (2017) 7761–7777.10.1364/OE.25.007761 ↗
20. Chen Z., Milner T., Srinivas S., Wang X., Malekafzali A., van Gemert M., Nelson J., Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography, Opt. Lett., 22: 14 (1997a) 1119–1121.10.1364/OL.22.001119 ↗
21. Chen Z., Milner T., Dave D., Nelson J., Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media, Opt. Lett., 22: 1 (1997b) 64–66.10.1364/OL.22.000064 ↗
22. Chu K., Mojahed D., Fernandez C., Li Y., Liu L., Wilsterman E., Diephuis B., Birket S., Bowers H., Martin Solomon G., Schuster B., Hanes J., Rowe S., Tearney G., Particle-tracking microrheology using micro-optical coherence tomography, Biophys J., 111: 5 (2016) 1053–1063.10.1016/j.bpj.2016.07.020 ↗
23. Cito S., Ahn Y., Pallares J., Duarte R., Chen Z., Madou M., Katakis I., Visualization and measurement of capillary-driven blood flow using spectral domain optical coherence tomography, Microfluid Nanofluid, 13: 2 (2012) 227–237.10.1007/s10404-012-0950-6 ↗
24. Drexler W., Fujimoto J. (Eds.), Optical Coherence Tomography—Technology and Applications, Springer-Verlag Berlin Heidelberg, Springer Science and Business Media, 2008.
25. Drexler W., Liu M., Kumar A., Kamali T., Unterhuber A., Leitgeb R.A., Optical coherence tomography today: speed, contrast, and multimodality, J. of Biomedical Optics, 19: 7 (2014) 071412 (pp34).10.1117/1.JBO.19.7.071412 ↗
26. Dufour M., Lamouche G., Detalle V., Gauthier B., Sammut P., Low-coherence interferometry—an advanced technique for optical metrology in industry, Insight-Non-Destructive Testing and Condition Monitoring, 47: 4 (2005) 216–219.10.1784/insi.47.4.216.63149 ↗
27. Dürr S., Thomason J.C. (Eds.), Biofouling, Blackwell Publishing, Oxford, 2010.10.1002/9781444315462 ↗
28. Eley R., Applied rheology in the protective and decorative coatings industry, Rheology Reviews, 5 (2005) 173–240.
29. Fabritius T., Optical method for liquid sorption measurements in paper, doctoral thesis, University of Oulu, 2007.
30. Gao Y., Haavisto S., Tang C., Salmela J., Li W., Characterization of fluid dynamics in spacer-filled channels for membrane filtration using Doppler optical coherence tomography, Journal of Membrane Science, 448 (2013) 198–208.10.1016/j.memsci.2013.08.011 ↗
31. Gao Y., Haavisto S., Tang C., Salmela J., Li W., Novel approach to characterizing thegGrowth of a fouling layer during membrane filtration via optical coherence tomography, Environ. Sci. Technol., 48: 24 (2014) 14273–14281.10.1021/es503326y ↗
32. Ghiglia D., Pritt M., Two-Dimensional Phase-Unwrapping: Theory, Algorithm, and Software, Wiley, New York, 1998.
33. Grulkowski I., Szkulmowski M., Bukowska D., Tamborski S., Gorczynska I., Kowalczyk A., Wojtkowski M., True velocity mapping using joint spectral and time domain optical coherence tomography, Ophthalmic Technologies XX, International Society for Optics and Photonics, 7550 (2010) 75500G (pp7).10.1117/12.842522 ↗
34. Haavisto S., Koponen A., Salmela J., New insight into rheology and flow properties of complex fluids with Doppler optical coherence tomography, Front. Chem., 2 (2014) 27(pp6).10.3389/fchem.2014.00027 ↗
35. Haavisto S., Salmela S., Jäsberg A., Saarinen T., Sorvari A., Koponen A., Rheological characterization of MFC using optical coherence tomography, TAPPI Journal, 14: 5 (2015a) 291–302.10.32964/10.32964/TJ14.5.291 ↗
36. Haavisto S., Salmela J., Koponen A., Accurate velocity measurements of boundary-layer flows using Doppler optical coherence tomography, Exp. Fluids, 56: 5 (2015b) 96 (pp6). DOI: 10.1007/s00348-015-1962-210.1007/s00348-015-1962-2 ↗
37. Haavisto S., Cardona M., Salmela J., Powell R., McCarthy M., Kataja M., Koponen A., Experimental investigation of the flow dynamics and rheology of complex fluids in pipe flow by hybrid multi-scale velocimetry, Exp. Fluids, 58: 11 (2017) 158(pp13). DOI: 10.1007/s00348-017-2440-910.1007/s00348-017-2440-9 ↗
38. Haavisto S., Application of Doppler optical coherence tomography in velocity profiling rheometry of complex fluids, Ph’D thesis, University of Jyväskylä, 2018.
39. Han Q., Li W., Trinh T., Fane A., Chew J., Effect of the surface charge of monodisperse particulate foulants on cake formation, Journal of Membrane Science, 548 (2018) 108–116.10.1016/j.memsci.2017.11.017 ↗
40. Harvey M., Waigh T.A., Optical coherence tomography velocimetry in controlled shear flow, Phys. Rev. E, 83:3 (2011) 031502(pp5).10.1103/PhysRevE.83.031502 ↗
41. Heise B., Wiesauer K., Götzinger E., Pircher M., Hitzenberger C., Engelke R., Ahrens G., Grützner G., Stifter D., Spatially resolved stress measurements in materials with polarization-sensitive optical coherence tomography: image acquisition and processing aspects, Strain, 46 (2010) 61–68.10.1111/j.1475-1305.2008.00589.x ↗
42. Hendargo H., McNabb R., Dhalla A., Shepherd N., Izatt J., Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography, Biomed. Opt. Express, 2: 8 (2011) 2175–2188.10.1364/BOE.2.002175 ↗
43. Hierzenberger P., Leiss-Holzinger E., Heise B., Stifter D., Eder G., In-situ optical coherence tomography (OCT) for the time-resolved investigation of crystallization processes in polymers, Macromolecules, 47: 6 (2014) 2072–2079.10.1021/ma4023839 ↗
44. Hjertager L., Hjertager B., Deen N., Solberg T., Measurement of turbulent mixing in a confined wake flow using combined PIV and PLIF, The Canadian Journal of Chemical Engineering, 81: 6 (2003) 1149–1158.10.1002/cjce.5450810604 ↗
45. Hong M. (Ed.), Coronary Imaging and Physiology, Springer, Singapore, 2018.10.1007/978-981-10-2787-1 ↗
46. Huang B., Choma M., Resolving directional ambiguity in dynamic light scattering-based transverse motion velocimetry in optical coherence tomography, Opt Lett., 39: 3 (2014) 521–524.10.1364/OL.39.000521 ↗
47. Huang B., Choma M., Microscale imaging of cilia-driven fluid flow, Cell. Mol. Life Sci. 72: 6 (2015) 1095–1113.10.1007/s00018-014-1784-z ↗
48. Huber R., Wojtkowski M., Fujimoto J., Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography, Optics Express, 14: 8 (2006) 3225–3237.10.1364/OE.14.003225 ↗
49. Huber R., Adler D., Srinivasan V., Fujimoto J., Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second, Opt. Lett., 32: 14 (2007) 2049–2051.10.1364/OL.32.002049 ↗
50. Jaradat S., Harvey M., Waigh T., Shear-banding in polyacrylamide solutions revealed via optical coherence tomography velocimetry, Soft Matt, 8 (2012) 11677–11686.10.1039/c2sm26395e ↗
51. Jonas S., Bhattacharya D., Khokha M., Choma M., Microfluidic characterization of cilia-driven fluid flow using optical coherence tomography-based particle tracking velocimetry, Biomed. Opt. Express, 2: 7 (2011) 2022–2034.10.1364/BOE.2.002022 ↗
52. Ju M.,Hong Y.-J., Makita S., Lim Y., Kurokawa K., Duan L., Miura M., Tang S., Yasuno Y., Advanced multi-contrast Jones matrix optical coherence tomography for Doppler and polarization sensitive imaging, Optics Express, 21: 16 (2013) 19412–19436.10.1364/OE.21.019412 ↗
53. Kalkman J., Bykov A., Faber D., van Leeuwen T., Multiple and dependent scattering effects in Doppler optical coherence tomography, Optics Express, 18: 4 (2010) 3883–3892.10.1364/OE.18.003883 ↗
54. Kashani A., Chen C.-L., Gahm J., Zheng F., Richter G., Rosenfeld P., Shi Y., Wang R., Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications, Progress in Retinal and Eye Research, 60 (2017) 66–100.10.1016/j.preteyeres.2017.07.002 ↗
55. Kataja M., Haavisto S., Lehto R., Salmela J., Koponen A., Characterization of microfibrillated cellulose fibre suspension flow using multi scale velocity profile measurements, Nordic Pulp and Paper Research Journal, 32: 3 (2017) 473–482.10.3183/npprj-2017-32-03-p473-482 ↗
56. Kawasaki M. (Ed.), Optical Coherence Tomography, InTechOpen, 2013.10.5772/56293 ↗
57. Kim J., Brown W., Maher J., Levinson H., Wax A., Functional optical coherence tomography: principles and progress, Phys. Med. Biol., 60: 10 (2015) R211–R237.10.1088/0031-9155/60/10/R211 ↗
58. Kirk R., Othmer D., Kirk-Othmer Food and Feed Technology, Wiley Interscience, 2008.
59. Koller D., Hannesschläger G., Leitner M., Khinast J., Non-destructive analysis of tablet coatings with optical coherence tomography, European Journal of Pharmaceutical Sciences, 44: 1–2 (2011) 142–148.10.1016/j.ejps.2011.06.017 ↗
60. Koponen A., Lauri J., Haavisto S., Fabritius T., Rheological and flocculation analysis of microfibrillated cellulose suspension using optical coherence tomography, Applied Sciences, 8 (2018) 775(pp10).10.3390/app8050755 ↗
61. Kukulka D., Baier R., Mollendorf J., Factors associated with fouling in the process industry, Heat Transfer Engineering, 25: 5 (2004) 23–29.10.1080/01457630490458978 ↗
62. Kumar S., Verma Y., Sharma P., Shrimali R., Gupta P., Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography, Appl. Phys. B, 117: 1 (2014) 395–399.10.1007/s00340-014-5848-4 ↗
63. Lauri J., Bykov A., Priezzhev V., Myllylä R., Experimental study of the multiple scattering effect on the flow velocity profiles measured in intralipid phantoms by DOCT, Laser Physics, 21: 4 (2011a) 813–817.10.1134/S1054660X11070164 ↗
64. Lauri J., Bykov A., Myllylä R., Determination of suspension viscosity from the flow velocity profile measured by Doppler optical coherence tomography, Photonics Letters of Poland, 3: 2 (2011b) 82–84.10.4302/plp.2011.2.13 ↗
65. Lauri J., Czajkowski J., Myllylä R., Fabritius T., Measuring flow dynamics in a microfluidic chip using optical coherence tomography with 1 μm axial resolution, Flow Meas. Instrum., 43 (2015) 1–5.10.1016/j.flowmeasinst.2015.02.001 ↗
66. Lauri J., Koponen A., Czajkowski J., Haavisto S., Fabritius T., Analysis of rheology and wall depletion of microfibrillated cellulose using optical coherence tomography, Cellulose, 24: 11 (2017) 4715–4728.10.1007/s10570-017-1493-5 ↗
67. Lawman S., Williams B., Zhang J., Shen Y.-C., Zheng Y., Scan-less line field optical coherence tomography, with automatic image segmentation, as a measurement tool for automotive coatings, Applied Sciences, 7: 4 (2017a) 351 (pp13).10.3390/app7040351 ↗
68. Lawman S., Madden P., Romano V., Dong Y., Mason S., Williams B., Kaye S., Willoughby C., Harding S., Shen Y.-C., Zheng Y., Deformation velocity imaging using optical coherence tomography and its applications to the cornea, Biomed. Opt. Express, 8: 12 (2017b) 5579–5593.10.1364/BOE.8.005579 ↗
69. Lexer F., Hitzenberger C., Fercher A., Kulhavy M., Wavelength-tuning interferometry of intraocular distances, Appl. Opt., 36: 25 (1997) 6548–6553.10.1364/AO.36.006548 ↗
70. Lee J., Bathany C., Ahn Y., Takayama S., Jung W, Volumetric monitoring of aqueous two phase system droplets using time-lapse optical coherence tomography, Laser Phys. Lett., 13 (2016) 025606(pp5).10.1088/1612-2011/13/2/025606 ↗
71. Leitgeb R., Werkmeister R., Blatter C., Schmetterer L., Doppler optical coherence tomography, Prog. Retinal Eye Res., 41 (2014) 26–43.10.1016/j.preteyeres.2014.03.004 ↗
72. Li C., Wagner M., Lackner S., Horn H., Assessing the influence of biofilm surface roughness on mass transfer by combining optical coherence tomography and two-dimensional modeling, Biotechnol. Bioeng., 1135 (2016) 989–1000.10.1002/bit.25868 ↗
73. Liu G., Chen Z., Advances in Doppler OCT, Chin. Opt. Lett., 11: 1 (2013) 011702(pp27).10.3788/COL201311.011702 ↗
74. Malm A., Harrison A., Waigh T., Optical coherence tomography velocimetry of colloidal suspensions, Soft Matter, 10: 41 (2014) 8210–8215.10.1039/C4SM01111B ↗
75. Malm A., OCT velocimetry and X-ray scattering rheology of complex fluids, doctoral thesis, University of Manchester, 2015.
76. Malm A., Waigh T., Elastic turbulence in entangled semi-dilute DNA solutions measured with optical coherence tomography velocimetry, Sci. Rep., 7 (2017) 1186(pp13).10.1038/s41598-017-01303-4 ↗
77. Manukyan S., Sauer H., Roisman I., Baldwin K., Fairhurst D., Liang H., Venzmer J., Tropea C., Imaging internal flows in a drying sessile polymer dispersion drop using Spectral Radar Optical Coherence Tomography (SR-OCT), J. Colloid Interface Sci., 395 (2013) 287–293.10.1016/j.jcis.2012.11.037 ↗
78. Markl D., Hannesschläger G., Sacher S., Leitner M., Khinast J., Optical coherence tomography as a novel tool for in-line monitoring of a pharmaceutical film-coating process, Eur. J. Pharm. Sci., 55 (2014a) 58–67.10.1016/j.ejps.2014.01.011 ↗
79. Markl D., Hannesschläger G., Buchsbaum A., Sacher S., Khinast J., Leitner M., In-line quality control of moving objects by means of spectral-domain OCT, Optics and Lasers in Engineering, 59 (2014b) 1–10.10.1016/j.optlaseng.2014.02.008 ↗
80. Markl D., Hannesschläger G., Sacher S., Leitner M., Khinast J., Buchsbaum A., Automated pharmaceutical tablet coating layer evaluation of optical coherence tomography images, Meas. Sci. Technol., 26 (2015a) 035701(pp12).10.1088/0957-0233/26/3/035701 ↗
81. Markl D., Zettl M., Hannesschläger G., Sacher S., Leitner M., Buchsbaum A., Khinast J., Calibration-free in-line monitoring of pellet coating processes via optical coherence tomography, Chemical Engineering Science, 125 (2015b) 200–208.10.1016/j.ces.2014.05.049 ↗
82. Michaely R., Bachmann A., Villiger M., Blatter C., Lasser T., Leitgeb R., Vectorial reconstruction of retinal blood flow in three dimensions measured with high resolution resonant Doppler Fourier domain optical coherence tomography, J. Biomed. Opt., 12(4) (2007) 041213(pp7).10.1117/1.2771553 ↗
83. Mujat M., Ferguson R., Iftimia N., Hammer D., Nedyalkov I., Wosnik M., Legner H., Optical coherence tomography-based micro-particle image velocimetry, Opt. Lett., 38: 22 (2013) 4558–4561.10.1364/OL.38.004558 ↗
84. Nemeth A., Gahleitner R., Hannesschläger G., Pfandler G., Leitner M., Ambiguity-free spectral-domain optical coherence tomography for determining the layer thicknesses in fluttering foils in real time, Optics and Lasers in Engineering, 50: 10 (2012) 1372–1376.10.1016/j.optlaseng.2012.05.015 ↗
85. Park B., Pierce M., Cense B., de Boer J., Real-time multi-functional optical coherence tomography, Optics Express, 11: 7 (2003) 782–793.10.1364/OE.11.000782 ↗
86. Park S., You J., Ahn Y., Jung W., Kim J., Lee S., Park J., Cho K., Evaluating the effects of organic matter bioavailability on nanofiltration membrane using real-time monitoring, J. Membr. Sci., 548 (2018) 519–525.10.1016/j.memsci.2017.11.053 ↗
87. Piao D., Otis L., Zhu Q., Doppler angle and flow velocity mapping by combined Doppler shift and Doppler bandwidth measurements in optical Doppler tomography, Opt. Lett., 28: 13 (2003) 1120–1122.10.1364/OL.28.001120 ↗
88. Popescu D., Choo-Smith L.-P., Flueraru C., Mao Y., Chang S., Disano J., Sherif S., Sowa M., Optical coherence tomography: fundamental principles, instrumental designs and biomedical applications, Biophysical Reviews, 3: 155 (2011) 155–169.10.1007/s12551-011-0054-7 ↗
89. Powell R., Experimental techniques for multiphase flows, Phys. Fluids, 20: 4 (2008) 040605(pp12).10.1063/1.2911023 ↗
90. de Pretto L., Nogueira G., Freitas A., Microfluidic volumetric flow determination using optical coherence tomography speckle: An autocorrelation approach, Journal of Applied Physics, 119 (2016) 163105(pp5).10.1063/1.4947282 ↗
91. Proskurin S., He Y., Wang R., Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography, Opt. Lett., 28: 14 (2003a) 1227–1229.10.1364/OL.28.001227 ↗
92. Proskurin S., Sokolova I., Wang R., Imaging of non-parabolic velocity profiles in converging flow with optical coherence tomography, Phys. Med. Biol., 48 (2003b) 2907–2918.10.1088/0031-9155/48/17/311 ↗
93. Ren H., Brecke K., Ding Z., Zhao Y., Nelson J., Chen Z., Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography, Opt. Lett., 27: 6 (2002) 409–411.10.1364/OL.27.000409 ↗
94. Saarinen T., Haavisto S., Sorvari A., Salmela J., Seppälä J., The effect of wall depletion on the rheology of microfibrillated cellulose water suspensions by Optical Coherence Tomography, Cellulose, 21: 3 (2014) 1261–1275.10.1007/s10570-014-0187-5 ↗
95. Salmela J., Haavisto S., Koponen A., Jäsberg A., Kataja M., Rheological characterization of micro-fibrillated cellulose fibre suspension using multi scale velocity profile measurements, proceedings of 15th Fundamental Research Symposium, Robinson College, Cambridge, UK. 8th–13th September 2013, 495–509.
96. Schneider S., Eppler F., Weber M., Olowojoba G., Weiss P., Hübner C., Mikonsaari I., Freude W., Koos C., Multiscale dispersion-state characterization of nanocomposites using optical coherence tomography, Sci. Rep., 6 (2016) 31733 (pp12).10.1038/srep31733 ↗
97. Schoenitz M., Grundemann L., Augustin W., Scholla S., Fouling in microstructured devices: a review, Chem. Commun., 51: 39 (2015) 8213–8228.10.1039/C4CC07849G ↗
98. Shang L., Cheng Y., Zhao Y., Emerging droplet microfluidics, Chem. Rev., 117: 12 (2017) 7964–8040.10.1021/acs.chemrev.6b00848 ↗
99. Sharma R., Papagiannopoulos A., Waigh T., Optical coherence tomography picorheology of biopolymer solutions, Appl. Phys. Lett., 92: 17 (2008) 173903(pp3).10.1063/1.2917578 ↗
100. Shen Z., Zeng N., He Y., Transverse flow-velocity quantification using optical coherence tomography with correlation, J. Phys.: Conf. Ser., 277 (2011) 012033(pp6).10.1088/1742-6596/277/1/012033 ↗