Design on the Prestressed Concrete Frame Beam-column
Source abstract
Abstract
A bidirectional ribbed concrete beam slab structure was widly adopted for the upper space of industrial buildings. To maintain ample space and minimize the presence of conventional columns, a bidirectional prestressed concrete beam is often employed. The intersection node of the prestressed concrete frame beam column was characterized by a high density of steel reinforcement, significant structural loads, and complex construction requirements. To ensure the quality, safety, and progress of prestressed frame beam-column intersection nodes during construction, this article proposed a new technology for constructing such nodes, which includes setting the tensioning and haunching ends of nodes at different positions, using ABAQUS finite element software to optimize the design of cross-sectional dimensions, conducting stress analysis simulations.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Xiong XY, Zhang S. Research on Seismic Performance of Prestressed Concrete Beams with Bonded and Unbonded Mixed Configurations under Vertical Low Cyclic Loading[J]. Building Structure, 2018, 48(8): 41–45
2. Li KZ, Cao GH, Yang LG. Experimental Study on the Performance Evaluation of Prestressed Concrete Continuous Box Girders under Different Cracking States[J]. Journal of Central South University, 2020, 51(12): 3 475–3 483
3. Architectural Institute of Japan. AIJ Standards for Structural Calculation of Steel Reinforced Concrete Structures: AIJ-SRC[S]. Tokyo: Architectural Institute of Japan, 2001
4. American Concrete Institute. Building Code Requirements for Structural Concrete and Commentary: ACI 318–2014[S]. Farmington Hills: American Concrete Institute, 2014
5. CEN/TC250. Eurocode 4: Design of Composite Steel and Concrete Structures-Part 1–1: General Rules and Rules for Buildings: EN 1994-1-1[S]. Brussels: European Committee for Standardization, 2004
6. China Institute of Building Standard Design and Research. Representation Method and Construction Details of Construction Drawings for Post Tensioned Prestressed Concrete Structures: 06SG429[S]. Beijing: China Planning Press, 2006
7. Na ZY, Wang XF, Zhao GG. Summary and Development of End Connection Methods for Prestressed Concrete Double T-Plate[J]. Building Structure, 2020, 50(13): 7–12
8. Yan LJ, Hu JX, Dai BM. Research on the Development of Beam Column Joints in Prcast Concrete Frames[J]. Journal of Disaster Prevention and Reduction, 2022, 38(02): 9–15
9. Zhang F, Ma JX, Nan Y. Parameters Selection and Verification Calculation of Concrete Plastic Damage Model[J]. China Concrete and Cement Products, 2021(01): 7–11+29
10. Xiong JG, Ding L, Tian Q. Calculation Method and Experimental Verification of Concrete Damage Plastic Model Parameters[J]. Journal of Nanchang University (Engineering & Technology), 2019, 41(01): 21–26
11. Tao MX, Nie JG. Nonlinear Finite Element Analysis of Prestressed of Steel-Concrete Composite Beams[J]. China Journal of Civil Engineering, 2011, 44(02): 8–14+16–20
12. Nie JG, Wang YH. Comparative Study on Concrete Constitutive Model in ABAQUS for Simulating Static Behavior of Structures[J]. EngineeringMechanics, 2013, 30(04): 59–67+82
13. Ministry of Housing, Urban and Rural Construction of the People’s Republic of China. Code for Design of Concrete Structures (GB50010-2010)[S]. Beijing: China Construction Industry Press, 2011
14. Wu JL, Yang H, Guo ZX. Numerical Analysis of Seismic Performance of Beam Column Joints in Partially Post Tensioned Prefabricated Concrete Frames[J]. Industrial Construction, 2023, 53(03): 28–34
15. Hawileh RA, Musto HA, Abdalla JA, et al. Finite Element Modeling of Reinforced Concrete Beams Externally Strengthened in Flexure with Side-Bonded FRP Laminates[J]. Composites Part B, 2019, 173(0): 10695210.1016/j.compositesb.2019.106952 ↗