A novel open C-shaped molar band for orthodontic applications: Mechanical characterizations and clinical trials
Source abstract
Abstract
To evaluate the retention properties of the novel ‘C’-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement (RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanical properties of the band were examined and the retention performance was characterized in the mesial, distal and vertical directions. A clinical trial was conducted using a spilt-mouth design on 50 patients. The novel C-shaped molar bands fit most molars without a repeated try-in process.The use of both nano-HA coating and RMGIC enhanced the tensile (8.00 ± 1.8 MPa) and shear strengths (27.17 ± 8.6 MPa) of the molar bands, leading to high retention in vertical, mesial and distal directions (p < 0.001). In clinical trials, the C-shaped molar bands had a failure rate (15%) comparable to that of traditional bands, and 93% of the failed bands demonstrated an adhesive remnant index score of 0, corroborating the observation that no luting agent residue remained on the tooth surface in most cases. The novel C-shaped molar bands appear to be a promising appliance that requires further clinical investigations, and may be used effectively in orthodontics.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Banks P, Macfarlane T. Bonded versus Banded First Molar Attachments: A Randomized Controlled Clinical Trial[J]. J. Orthod., 2007, 34: 128–13610.1179/146531207225022032 ↗
2. Pandis N, Christensen L, Eliades T. Long-term Clinical Failure Rate of Molar Tubes Bonded with A Self-etching Primer[J]. Angle Othod., 2005, 75: 1000–1002
3. Malkoc S, Corekci B, Botsali H, et al. Cytotoxic Effects of Resinmodified Orthodontic Band Adhesives. Are They Safe[J]. Angle Othod., 2010, 80: 890–89510.2319/101509-577.1 ↗
4. Fulford MR, Ireland AJ, Main BG. Decontamination of Tried-in Orthodontic Molar Bands[J]. European Journal of Orthodontics, 2003, 25: 621–62210.1093/ejo/25.6.621 ↗
5. Dowsing P, Benson PE. Molar Band Re-use and Decontamination: A Survey of Specialists[J]. Journal of Orthodontics, 2006, 33: 30–3710.1179/146531205225021366 ↗
6. Zhou S, Zhang B, Wang P, et al. A New Open “C”-shaped Molar Band with Nonomaterial[P]. 201110057699.1, 2001
7. Muraoka R, Nakano K, Kurihara S, et al. Immunohistochemical Expression of Heat Shock Proteins in the Mouse Periodontal Tissues Due to Orthodontic Mechanical Stress[J]. Eur. J. Med. Res., 2010, 15: 475–48210.1186/2047-783X-15-11-475 ↗
8. Harrington Z, Darbar U. Localised Periodontitis Associated with An Ectopic Orthodontic Separator[J]. Prim. Dent. Care., 2007, 14: 5–610.1308/135576107779398101 ↗
9. Finkbeiner R, Nelson L, Killebrew J. Accidental Orthodontic Elastic Band-induced Periodontitis: Orthodontic and Laser Treatment[J]. J. Am. Dent. Assoc., 1997, 128: 1565–156910.14219/jada.archive.1997.0097 ↗
10. Mickenautsch S, Yengopal V, Banerjee A. Pulp Response to Resinmodified Glass Ionomer and Calcium Hydroxide Cements in Deep Cavities: A Quantitative Systematic Review[J]. Dental Materials, 2010, 26: 761–77010.1016/j.dental.2010.03.021 ↗
11. Aboush Y, Torabzadeh H. Fluoride Release From Tooth-Colored Restorative Materials: A 12-Month Report[J]. J. Can. Dent. Assoc., 1998, 64: 561–564
12. Kawakami T, Antoh M, Hasegawa H, et al. Experimental Study on Osteoconductive Properties of A Chitosan-Bonded Hydroxyapatite Self-Hardening Paste[J]. Biomaterials, 1992, 13: 759–76310.1016/0142-9612(92)90014-F ↗
13. Kim H, Kim M, Jang J, et al. Ostogenic Differentitation of Bone Marrow Stem Cell in Poly (Lactic-Co-Glycolic Acid) Scaffold Loaded Various Ratio of Hydroxyapatite[J]. Int. J. Stem Cells, 2013, 6: 67–7410.15283/ijsc.2013.6.1.67 ↗
14. Leung V, Darvell B. Calcium Phosphate System in Saliva-Like Media[J]. J. Chem. Soc. Faraday. Trans., 1991, 87: 1759–176410.1039/ft9918701759 ↗
15. Sugimoto T, Zhou X. Synthesis of Uniform Anatase TiO2 Nanoparticles by the Gel-Sol Method 2. Adsorption of OH-Ions to Ti(OH)4 Gel and TiO2 Particles[J]. J. Colloid. Interface. Sci., 2002, 252: 347–35310.1006/jcis.2002.8480 ↗
16. Sugimoto T, Okada K, Itoh H. Synthetic of Uniform Spindle-Type Titania Particles by the Gel-Sol Method[J]. J. Colloid. Interface. Sci., 1997, 193: 140–14310.1006/jcis.1997.5037 ↗
17. Millett D, Mandall N, Hickman J, et al. Adhesives for Fixed Orthodontic Bands. A Systematic Review[J]. Angle Othod., 2009, 79: 193–19910.2319/081307-377.1 ↗
18. Laureano Filho J, Godoy F, O’Ryan F. Orthodontic Bracket Lost in the Airway During Orthognathic Surgery[J]. Am. J. Orthod. Dentofacial. Orthop., 2008, 134: 288–29010.1016/j.ajodo.2008.04.017 ↗
19. Vilar R, Souza N, Cal-Neto J, et al. Shear Bond Strength of Brackets Bonded with Two Light-Curing Orthodontic Adhesives[J]. J. Adhes. Dent., 2009, 11: 259–262
20. Juneja A, Bagga D, Sharma R, et al. A Comparative Evaluation of Separation Effect and Perception of Pain Using Two Different Orthodontic Separators[J]. J. Ind. Orthod. Soc., 2011, 45: 183–18810.5005/jp-journals-10021-1032 ↗
21. Norris D, McInnes-Ledoux P, Schwaninger B, et al. Retention of Orthodontic Bands with New Fluoride-Releasing Cements[J]. Am. J. Orthod., 1986, 89: 206–21110.1016/0002-9416(86)90033-3 ↗
22. Wiltshire W. Shear Bond Strengths of A Glass Ionomer for Direct Bonding in Orthodontics[J]. Am. J. Orthod. Dentofacial. Orthop., 1994, 106: 127–13010.1016/S0889-5406(94)70029-X ↗
23. Bowen R, Marjenhoff W. Dental Composites/Glass Ionomers: the Materials[J]. Adv. Dent. Res., 1992, 6: 44–4910.1177/08959374920060011601 ↗
24. Li S, Hobson R, Bai Y, et al. A Method for Producing Controlled Fluoride Release from An Orthodontic Bracket[J]. Eur. J. Orthod., 2007, 29: 550–55410.1093/ejo/cjm046 ↗
25. Millett D, Duff S, Morrison L, et al. In Vitro Comparison of Orthodontic Band Cements[J]. Am. J. Orthod. Dentofacial. Orthop., 2003, 123: 15–2010.1067/mod.2003.48 ↗
26. Millett D, Cummings A, Letters S, et al. Resin-Modified Glass Ionomer, Modified Composite or Conventional Glass Ionomer for Band Cementation-An in Vitro Evaluation[J]. Eur. J. Orthod., 2003, 25: 609–61410.1093/ejo/25.6.609 ↗
27. Johnson N. Orthodontic Banding Cement[J]. J. Orthod., 2000, 27: 283–28410.1179/ortho.27.3.283 ↗
28. Mennemeyer V, Neuman P, Powers J. Bonding of Hybrid Ionomers and Resin Cements to Modified Orthodontic Band Materials[J]. Am. J. Orthod. Dentofacial. Orthop., 1999, 115: 143–14710.1016/S0889-5406(99)70341-0 ↗
29. Millett D, Kamahli K, McColl J. Comparative Laboratory Investigation of Dual-Cured vs Conventional Glass Ionomer Cements for Band Cementation[J]. Angle Othod., 1998, 68: 345–350
30. Fricker J, Mclachlan M. Clinical Studies of Glass Ionomer Cements. Part 1-a Twelve Month Clinical Study Comparing Zinc Phosphate Cement to Glass Ionomer[J]. Aust. Orthod. J., 1985, 9: 179–180
31. Millett D, Gordon P. The Performance of First Molar Orthodontic Bands Emented with Glass Ionomer Cement-A Retrospective Analysis[J]. Br. J. Orthod., 1992, 19: 215–22010.1179/bjo.19.3.215 ↗
32. Maijer R, Smith D. A Comparison Between Zinc Phosphate and Glass Ionomer Cement in Orthodontics[J]. Am. J. Orthod. Dentofacial. Orthop., 1988, 93: 273–27910.1016/0889-5406(88)90156-4 ↗
33. Fricker J. A 12-Month Clinical Study Comparing Four Glass Ionomer Cements for the Cementation of Orthodontic Molar Bands[J]. Aust. Orthod. J., 1989, 11: 10–13
34. Panolis N, Christensen L, Eliades T. Long-Term Clinical Failure Rate of Molar Tubes Bonded with A Self-Etching Primer[J]. Angle Orthod., 2005, 75: 1000–1002
35. Gottlieb E, Nelson A, Vogel D. Study of Orthodontic Diagnosis and Treatment Procedures, Part 1: Overall Results[J]. J. Clin. Orthod., 1986, 20: 612–625
36. Stirrups D. A Comparative Clinical Trial of A Glass Ionomer and A Zinc Phosphate Cement for Securing Orthodontic Bands[J]. Br. J. Orthod., 1991, 18: 15–2010.1179/bjo.18.1.15 ↗