journal article·2023-09Open access

Moving towards in pouch diagnostics for ostomy patients: exploiting the versatility of laser induced graphene sensors

Conor McCann, Victoria Gilpin, Cameron Scott, L. Kirsty Pourshahidi, Chris. I. R. Gill, James Davis

Journal of Materials Science· Volume 58· Issue 35

Abstract

Abstract The development of a 3D printed sensor for direct incorporation within stoma pouches is described. Laser induced graphene scribed on either side of polyimide film served as the basis of a 2 electrode configuration that could be integrated within a disposable pouch sensor for the periodic monitoring of ileostomy fluid pH. The graphene sensors were characterised using electron microscopy, Raman spectroscopy, DekTak profilometry with the electrochemical properties investigated using both cyclic and square wave voltammetry. Adsorbed riboflavin was employed as a biocompatible redox probe for the voltammetric measurement of pH. The variation in peak position with pH was found to be linear over pH 3–8 with a sub Nernstian response (43 mV/pH). The adsorbed probe was found to be reversible and exhibited minimal leaching through repeated scanning. The performance of the system was assessed in a heterogeneous bacterial fermentation mixture simulating ileostomy fluid with the pH recorded before and after 96 h incubation. The peak profile in the bacterial medium provided an unambiguous signal free from interference with the calculated pH before and after incubation (pH 5.3 to 3.66) in good agreement with that obtained with commercial pH probes. Graphical abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Hydrogels: synthesis, properties, applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (76)

Show source-provided references
1. Hill B (2020) Stoma care: procedures, appliances and nursing considerations. Br J Nurs 29:S14–S1910.12968/bjon.2020.29.22.S14 ↗
2. Colostomy UK (2021) Step up for stomas. https://www.colostomyuk.org/ active-ostomates/step-up-for-stomas/ (Accessed 27 Apr 2023)
3. NHS Digital. (2021) Hospital admitted patient care activity 2020–21. https://digital.nhs.uk/data-and-information/publications/statistical/hospital-admitted-patient-care-activity/2020-21 (Accessed 27 Apr 2023)
4. Matarese LE (2013) Nutrition and fluid optimization for patients with short bowel syndrome. J Parenter Enteral Nutr 37:161–17010.1177/0148607112469818 ↗
5. Nightingale J, Woodward JM (2006) Guidelines for management of patients with a short bowel. Gut 55:1–1210.1136/gut.2006.091108 ↗
6. Ng DHL, Pither CAR, Wootton SA, Stroud MA (2013) The “not so short-bowel syndrome”: potential health problems in patients with an ileostomy. Color Dis 15:1154–116110.1111/codi.12252 ↗
7. Fish DR, Mancuso CA, Garcia-Aguilar JE, Lee SW, Nash GM, Sonoda T, Charlson ME, Temple LK (2017) Readmission after ileostomy creation. Ann Surg 265:379–38710.1097/SLA.0000000000001683 ↗
8. Justiniano CF, Temple LK, Swanger AA, Xu Z, Speranza JR, Cellini C, Salloum RM, Fleming FJ (2018) Readmissions with dehydration after ileostomy creation: rethinking risk factors. Dis Colon Rectum 61:1297–130510.1097/DCR.0000000000001137 ↗
9. Messaris E, Sehgal R, Deiling S, Koltun WA, Stewart D, McKenna K, Poritz LS (2012) Dehydration Is the most common indication for readmission after diverting ileostomy creation. Dis Colon Rectum 55:175–18010.1097/DCR.0b013e31823d0ec5 ↗
10. Aibibula M, Burry G, Gagen H, Osborne W, Lewis H, Bramwell C, Pixley H, Cinque G (2022) Gaining consensus: the challenges of living with a stoma and the impact of stoma leakage. Br J Nurs 31:S30–S3910.12968/bjon.2022.31.6.S30 ↗
11. Porrett T, Nováková S, Schmitz K, Klimekova E, Aaes H (2011) Leakage and ostomy appliances: results from a large-scale, open-label study in clinical practice. Gastrointest Nurs 9(suppl 2):19–2310.12968/gasn.2011.9.Sup2.19 ↗
12. Fellows J, Voegeli D, Håkan-Bloch J, Herschend NO, Størling Z (2021) Multinational survey on living with an ostomy: prevalence and impact of peristomal skin complications. Br J Nurs 30:S22–S3010.12968/bjon.2021.30.16.S22 ↗
13. Gray M, Colwell JC, Doughty D, Goldberg M, Hoeflok J, Manson A, McNichol L, Rao S (2013) Peristomal moisture-associated skin damage in adults with fecal ostomies a comprehensive review and consensus. J Wound Ostomy Cont Nurs 40:389–39910.1097/WON.0b013e3182944340 ↗
14. Falloon K, Cohen BL, Ottichilo R, Grove D, Rieder F, Qazi T (2022) Biomarkers for the evaluation of pouch inflammation: a systematic review. Crohn’s Colitis 360:otac04310.1093/crocol/otac043 ↗
15. Daoud ND, Hashash JG, Picco MF, Farraye FA (2022) Faecal calprotectin from ileostomy output is sensitive and specific for the prediction of small bowel inflammation in patients with crohn’s disease. J Crohns Colitis 16:601–60510.1093/ecco-jcc/jjab182 ↗
16. Hu Z-D, Zhang K-P, Huang Y, Zhu S (2017) Compliance to self-monitoring of blood glucose among patients with type 2 diabetes mellitus and its influential factors: a realworld cross-sectional study based on the Tencent TDF-I blood glucose monitoring platform. mHealth 3:2510.21037/mhealth.2017.06.01 ↗
17. Moström P, Ahlén E, Imberg H, Hansson P-O, Lind M (2017) Adherence of self-monitoring of blood glucose in persons with type 1 diabetes in Sweden. BMJ Open Diabetes Res Care 5:e00034210.1136/bmjdrc-2016-000342 ↗
18. Ratliff CR (2014) Factors related to ostomy leakage in the community setting. J Wound Ostomy Cont Nurs 41:249–25310.1097/WON.0000000000000017 ↗
19. Casimero C, McConville A, Fearon JJ, Lawrence CL, Taylor CM, Smith RB, Davis J (2018) Sensor systems for bacterial reactors: a new flavin-phenol composite film for the in situ voltammetric measurement of pH. Anal Chim Acta 1027:1–810.1016/j.aca.2018.04.053 ↗
20. Barber R, Cameron S, Devine A, McCombe A, Pourshahidi LK, Cundell J, Roy S, Mathur A, Casimero C, Papakonstantinou P, Davis J (2021) Laser induced graphene sensors for assessing pH: application to wound management. Electrochem Commun 123:10691410.1016/j.elecom.2020.106914 ↗
21. Casimero C, Hegarty C, McGlynn RJ, Davis J (2020) Ultrasonic exfoliation of carbon fiber: electroanalytical perspectives. J Appl Electrochem 50:383–39410.1007/s10800-019-01379-y ↗
22. Luong DX, Subramanian AK, Silva GAL, Yoon J, Cofer S, Yang K, Owuor PS, Wang T, Wang Z, Lou J, Ajayan PM, Tour JM (2018) Laminated object manufacturing of 3D-printed laser-induced graphene foams. Adv Mater 30:1–610.1002/adma.201707416 ↗
23. Lin J, Peng Z, Liu Y, Ruiz-Zepeda F, Ye R, Samuel ELGG, Yacaman MJ, Yakobson BI, Tour JM (2014) Laser-induced porous graphene films from commercial polymers. Nat Commun 5:571410.1038/ncomms6714 ↗
24. Chyan Y, Ye R, Li Y, Singh SP, Arnusch CJ, Tour JM (2018) Laser-Induced graphene by multiple lasing: toward electronics on cloth, paper, and food. ACS Nano 12:2176–218310.1021/acsnano.7b08539 ↗
25. Kava AA, Henry CS (2021) Exploring carbon particle type and plasma treatment to improve electrochemical properties of stencil-printed carbon electrodes. Talanta 221:12155310.1016/j.talanta.2020.121553 ↗
26. Pankratova G, Pan JY, Keller SS (2022) Impact of plasma-induced surface chemistry on electrochemical properties of microfabricated pyrolytic carbon electrodes. Electrochim Acta 410:13998710.1016/j.electacta.2022.139987 ↗
27. Gao Z, Zhu J, Rajabpour S, Joshi K, Kowalik M, Croom B, Schwab Y, Zhang L, Bumgardner C, Brown KR, Burden D, Klett JW, van Duin ACT, Zhigilei LV, Li V (2020) Graphene reinforced carbon fibers. Sci Adv 6:eaaz419110.1126/sciadv.aaz4191 ↗
28. Rosenburg F, Ionescu E, Nicoloso N, Riedel R (2018) High-temperature raman spectroscopy of nano-crystalline carbon in silicon oxycarbide. Materials (Basel) 11:9310.3390/ma11010093 ↗
29. Benson J, Xu Q, Wang P, Shen Y, Sun L, Wang T, Li M, Papakonstantinou P (2014) Tuning the catalytic activity of graphene nanosheets for oxygen reduction reaction via size and thickness reduction. ACS Appl Mater Interfaces 6:19726–1973610.1021/am5048202 ↗
30. Duy LX, Peng Z, Li Y, Zhang J, Ji Y, Tour JM (2018) Laser-induced graphene fibers. Carbon 126:472–47910.1016/j.carbon.2017.10.036 ↗
31. Antal IP, Bazel YR, Kormosh ZA (2013) Electrochemical methods for determining group B vitamins. J Anal Chem 68:565–57610.1134/S1061934813070034 ↗
32. Yu YY, Wang JX, Si RW, Yang Y, Zhang CL, Yong YC (2017) Sensitive amperometric detection of riboflavin with a whole-cell electrochemical sensor. Anal Chim Acta 985:148–15410.1016/j.aca.2017.06.053 ↗
33. Roushani M, Valipour A (2016) Voltammetric immunosensor for human chorionic gonadotropin using a glassy carbon electrode modified with silver nanoparticles and a nanocomposite composed of graphene, chitosan and ionic liquid, and using riboflavin as a redox probe. Microchim Acta 183:845–85310.1007/s00604-015-1731-1 ↗
34. Roushani M, Shahdost-Fard F (2015) A novel ultrasensitive aptasensor based on silver nanoparticles measured via enhanced voltammetric response of electrochemical reduction of riboflavin as redox probe for cocaine detection. Sens Actuators, B Chem 207:764–77110.1016/j.snb.2014.10.131 ↗
35. Song W, Xiao Y, Song P, Wang C, Yang Z, Slade RCT, Zhao F (2016) Riboflavin-mediated extracellular electron transfer process involving Pachysolen tannophilus. Electrochim Acta 210:117–121. https://doi.org/10.1016/j.electacta.2016.05.13910.1016/j.electacta.2016.05.139 ↗
36. Valipour A, Roushani M (2017) Using silver nanoparticle and thiol graphene quantum dots nanocomposite as a substratum to load antibody for detection of hepatitis C virus core antigen: electrochemical oxidation of riboflavin was used as redox probe. Biosens Bioelectron 89:946–95110.1016/j.bios.2016.09.086 ↗
37. Roushani M, Abdi Z (2014) Novel electrochemical sensor based on graphene quantum dots/riboflavin nanocomposite for the detection of persulfate. Sens Actuators, B Chem 201:503–51010.1016/j.snb.2014.05.054 ↗
38. Pereira AC, de Santos AS, Kubota LT (2003) Electrochemical behavior of riboflavin immobilized on different matrices. J Colloid Interface Sci 265:351–35810.1016/S0021-9797(03)00477-6 ↗
39. Song N, Dares CJ, Sheridan MV, Meyer TJ (2016) Proton-coupled electron transfer reduction of a quinone by an oxide-bound riboflavin derivative. J Phys Chem C 120:23984–2398810.1021/acs.jpcc.6b08176 ↗
40. Celiešiūtė R, Radzevič A, Žukauskas A, Vaitekonis S, Pauliukaite R (2017) A strategy to employ polymerised riboflavin in the development of electrochemical biosensors. Electroanalysis 29:2071–208210.1002/elan.201700218 ↗
41. Radzevic A, Niaura G, Ignatjev I, Rakickas T, Celiešiute R, Pauliukaite R (2016) Electropolymerisation of the natural monomer riboflavin and its characterisation. Electrochim Acta 222:1818–183010.1016/j.electacta.2016.11.166 ↗
42. Sun W, Kong J, Deng J (1991) Electrocatalytic reduction of hemoglobin at a chemically modified electrode containing riboflavin. Electroanalysis 9:115–11910.1002/elan.1140090205 ↗
43. Roushani M, Karami E, Salimi A, Sahraeia R (2013) Amperometric detection of hydrogen peroxide at nano-ruthenium oxide/riboflavin nanocomposite-modified glassy carbon electrodes. Electrochim Acta 113:134–14010.1016/j.electacta.2013.09.069 ↗
44. Chatterjee A, Foord JS (2009) Biological applications of diamond electrodes; electrochemical studies of riboflavin. Diam Relat Mater 18:899–90310.1016/j.diamond.2009.02.016 ↗
45. Fiorda FA, de Melo Pereira GV, Thomaz-Soccol V, Rakshit SK, Pagnoncelli MGB, Vandenberghe LP, Soccol CR (2017) Microbiological, biochemical, and functional aspects of sugary kefir fermentation—a review. Food Microbiol 66:86–9510.1016/j.fm.2017.04.004 ↗
46. Gul O, Mortas M, Atalar I, Dervisoglu M, Kahyaoglu T (2015) Manufacture and characterization of kefir made from cow and buffalo milk, using kefir grain and starter culture. J Dairy Sci 98:1517–152510.3168/jds.2014-8755 ↗
47. Ntsame Affane AL, Fox GP, Sigge GO, Manley M, Britz TJ (2011) Simultaneous prediction of acidity parameters (pH and titratable acidity) in Kefir using near infrared reflectance spectroscopy. Int Dairy J 21:896–90010.1016/j.idairyj.2011.04.016 ↗
48. Singh SP, Li Y, Be’Er A, Oren Y, Tour JM, Arnusch CJ (2017) Laser-induced graphene layers and electrodes prevents microbial fouling and exerts antimicrobial action. ACS Appl Mater Interfaces 9:18238–1824710.1021/acsami.7b04863 ↗
49. Pan TM, Wang CW, Mondal S, Pang ST (2018) Super-Nernstian sensitivity in microfabricated electrochemical pH sensor based on CeTixOyfilm for biofluid monitoring. Electrochim Acta 261:482–49010.1016/j.electacta.2017.12.163 ↗
50. Lonsdale W, Wajrak M, Alameh K (2018) Manufacture and application of RuO2 solid-state metal-oxide pH sensor to common beverages. Talanta 180:277–28110.1016/j.talanta.2017.12.070 ↗
51. Chinnathambi S, Euverink GJW (2018) Polyaniline functionalized electrochemically reduced graphene oxide chemiresistive sensor to monitor the pH in real time during microbial fermentations. Sens Actuators, B Chem 264:38–4410.1016/j.snb.2018.02.087 ↗
52. Dang W, Manjakkal L, Navaraj WT, Lorenzelli L, Vinciguerra V, Dahiya R (2018) Stretchable wireless system for sweat pH monitoring. Biosens Bioelectron 107:192–20210.1016/j.bios.2018.02.025 ↗
53. Cisternas R, Ballesteros L, Valenzuela ML, Kahlert H, Scholz F (2017) Decreasing the time response of calibration-free pH sensors based on tungsten bronze nanocrystals. J Electroanal Chem 801:315–31810.1016/j.jelechem.2017.08.005 ↗
54. Chou J, Yan S, Liao Y, Lai C (2018) Characterization of flexible arrayed pH sensor based on nickel oxide films. IEEE Sens J 18:605–61210.1109/JSEN.2017.2773143 ↗
55. Mani GK, Miyakoda K, Saito A, Yasoda Y, Kajiwara K, Kimura M, Tsuchiya K (2017) Microneedle pH sensor: direct, label-free, real-time detection of cerebrospinal fluid and bladder pH. ACS Appl Mater Interfaces 9:21651–2165910.1021/acsami.7b04225 ↗
56. Padmanathan N, Shao H, Razeeb KM (2018) Multifunctional nickel phosphate nano/microflakes 3D electrode for electrochemical energy storage, nonenzymatic glucose, and sweat pH sensors. ACS Appl Mater Interfaces 10:8599–861010.1021/acsami.7b17187 ↗
57. Bause S, Decker M, Gerlach F, Näther J, Köster F, Neubauer P, Vonau W (2017) Development of an iridium-based pH sensor for bioanalytical applications. J Solid State Electrochem 22:1–10
58. Mani GK, Morohoshi M, Yasoda Y, Yokoyama S, Kimura H, Tsuchiya K (2017) ZnO-based microfluidic pH sensor: a versatile approach for quick recognition of circulating tumor cells in blood. ACS Appl Mater Interfaces 9:5193–520310.1021/acsami.6b16261 ↗
59. Parrilla M, Vanhooydonck A, Johns M, Watts R, De Wael K (2023) 3D-printed microneedle-based potentiometric sensor for pH monitoring in skin interstitial fluid. Sens Actuators, B Chem 378:13315910.1016/j.snb.2022.133159 ↗
60. Wang Y, Guo H, Yuan M, Yu J, Wang Z, Chen X (2023) One-step laser synthesis platinum nanostructured 3D porous graphene: A flexible dual-functional electrochemical biosensor for glucose and pH detection in human perspiration. Talanta 257:12436210.1016/j.talanta.2023.124362 ↗
61. Yin J, Chen W, Gao W, Zhang X, Tang B, Jin Q (2023) Batch fabrication of microminiaturized pH sensor integrated with IrOx film and solid state Ag/AgCl electrode for tap water quality online detection. IEEE Sens J 23:347510.1109/JSEN.2023.3234140 ↗
62. Zhao Y, Yu Y, Zhao S, Zhu R, Zhao J, Cui G (2023) Highly sensitive pH sensor based on flexible polyaniline matrix for synchronal sweat monitoring. Microchem J 185:10809210.1016/j.microc.2022.108092 ↗
63. Shylendra SP, Wajrak M, Alameh K (2023) Fabrication and optimization of nafion as a protective membrane for TiN-based pH sensors. Sensors 23:233110.3390/s23042331 ↗
64. Mahinnezhad S, Izquierdo R, Shihz A (2023) Fully printed pH sensor based on polyaniline/graphite nanocomposites. J Electrochem Soc 170:02750110.1149/1945-7111/acb5c3 ↗
65. Pan M, Luo S, Yan B, Ye J, Zhang S (2023) A novel TiO2–SnO2 film pH sensor prepared by micro-arc oxidation. J Electroanal Chem 929:11710310.1016/j.jelechem.2022.117103 ↗
66. Liu Y, Diao Y, Hu G, Zhao Y, Shi Y, Wang H, Li Z (2023) Renewable antimony-based pH sensor. J Electroanal Chem 928:11708510.1016/j.jelechem.2022.117085 ↗
67. Chaisiwamongkhol K, Batchelor-Mcauley C, Compton RG (2017) Amperometric micro pH measurements in oxygenated saliva. Analyst 142:2828–283510.1039/C7AN00809K ↗
68. Rahimi R, Ochoa M, Parupudi T, Zhao X, Yazdi IK, Dokmeci MR, Tamayol A, Khademhosseini A, Ziaie B (2016) A low-cost flexible pH sensor array for wound assessment. Sens Actuators, B Chem 229:609–61710.1016/j.snb.2015.12.082 ↗
69. Amiri M, Amali E, Nematollahzadeh A, Salehniya H (2016) Poly-dopamine films: voltammetric sensor for pH monitoring. Sens Actuators, B Chem 228:53–5810.1016/j.snb.2016.01.012 ↗
70. Saikrithika S, Premkumar J, Rajagopal D, Huh YS, Kumar AS (2023) In situ electro-organic synthesis and functionalization of catechol derivative on carbon black and its interference-free voltammetric pH sensor application. J Electrochem Soc 170:03550110.1149/1945-7111/acbfe5 ↗
71. Srinivas S, Ashokkumar K, Sriraghavan K, Kumar AS (2021) A prototype device of microliter volume voltammetric pH sensor based on carbazole–quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode. Sci Rep 11:1390510.1038/s41598-021-93368-5 ↗
72. Krishnan V, Ananth V, Velayutham J, Manickam P, Veerapandian M (2023) Bioadhesive gauze embedded with chitosan-butein bioconjugate: a redox-active ph sensor platform. Biosensors 13:610.3390/bios13010006 ↗
73. Miranda M, Carvetta C, Sisodia N, Shirley L, Day CD, McGuinness KL, Wadhawan JD, Lawrence NS (2022) Nafion® Coated electropolymerised flavanone-based pH sensor. Electroanalysis 34:1273–127910.1002/elan.202100652 ↗
74. Lee PT, Harfield JC, Crossley A, Pilgrim BS, Compton RG (2013) Significant changes in pKa between bulk aqueous solution and surface immobilized species: ortho hydroquinones. RSC Adv 3:7347–735410.1039/c3ra00164d ↗
75. Rowe KM, Schiller LR (2020) Ileostomy diarrhea: Pathophysiology and management. Proc (Bayl Univ Med Cent) 33:218–226
76. Nightingale JMD (2022) How to manage a high-output stoma, Frontline. Gastroenterology 13:140–151