journal article·2019-07Open access

Design of a smart sensor mesh for the measurement of pH in ostomy applications

Anna McLister, Charnete Casimero, Aaron McConville, Charlotte M. Taylor, Clare L. Lawrence, Robert B. Smith, Ashish Mathur, James Davis

Journal of Materials Science· Volume 54· Issue 14

Abstract

A carbon-loaded polyethylene film was modified through a combination of laser ablation and electrochemical anodisation to yield a mechanically flexible yet electroanalytically sensitive mesh. A custom flavin derivative bearing a pendant phenol substituent was electropolymerised onto the substrate, and its electrochemical properties were investigated. The reversible flavin electrochemistry was retained (Ep = −0.374 V vs. Ag/AgCl, pH 7), and the peak position was found to shift by 60 mV/pH over a range covering pH 2.55 to pH 8.12. The stability of the resulting composite has been evaluated, and the analytical applicability towards the voltammetric measurement of pH in human urine was critically assessed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrical and Bioimpedance Tomography · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Gray M, Colwell JC, Doughty D, Goldberg M, Hoeflok J, Manson A, McNichol L, Rao S (2013) Peristomal moisture-associated skin damage in adults with fecal ostomies. J Wound Ostomy Cont Nurs 40:389–39910.1097/WON.0b013e3182944340 ↗
2. Gray M, Black JM, Baharestani MM, Bliss DZ, Colwell JC, Goldberg M, Kennedy-Evans KL, Logan S, Ratliff CR (2011) Moisture associated skin damage. J Wound Ostomy Cont Nurs 38:233–24110.1097/WON.0b013e318215f798 ↗
3. Ratliff C (2010) Early peristomal skin complications reported by WOC nurses. J Wound Ostomy Cont Nurs 37:505–51010.1097/WON.0b013e3181edac57 ↗
4. Salvadalena GD (2013) The incidence of stoma and peristomal complications during the first 3 months after ostomy creation. J Wound Ostomy Cont Nurs 40:400–40610.1097/WON.0b013e318295a12b ↗
5. Colwell JC, Ratliff CR, Goldberg M, Baharestani MM, Bliss DZ, Gray M, Kennedy-Evans KL, Logan S, Black JM (2011) MASD Part 3: peristomal moisture associated dermatitis and periwound moisture-associated dermatitis. J Wound Ostomy Cont Nurs 38:541–55310.1097/WON.0b013e31822acd95 ↗
6. Burch J (2008) Stoma care. Wiley, Hoboken
7. Omura Y, Yamabe M, Anazawa S (2010) Peristomal skin disorder in patients with intestinal and urinary ostomies. J Wound Ostomy Cont Nurs 37:289–29810.1097/WON.0b013e3181d8c9d3 ↗
8. Wells J, Doughty D (1994) Pouching principles and products. Ostomy Wound Manag 40:50–63
9. Nybaek H, Lophagen S, Karlsmark T, Bang KD, Jemec G (2009) Stratum corneum integrity as a predictor for peristomal skin problems in ostomates. Br J Dermatol 162:357–36110.1111/j.1365-2133.2009.09418.x ↗
10. Ali SM, Yosipovitch G (2013) Skin pH: from basic science to basic skin care, acta derm. Venerol 93:261–26710.2340/00015555-1531 ↗
11. Leyden JJ, Stewart R, Kligman AM (1979) Updated in vivo methods for evaluating topical antimicrobial agents on human skin. J Invest Dermatol 72:165–17010.1111/1523-1747.ep12676347 ↗
12. Korting HC, Hubner K, Greiner K, Hamm G, Braun-Falco O (1990) Differences in the skin surface ph and bacterial microflora due to the long term application of synthetic detergent preparation of pH 5.5 and pH 7.0. results of a crossover trial in healthy volunteers. Acta Dermatol Venereol 70:429–43110.2340/0001555570429431 ↗
13. Rippke F, Schreiner V, Schwanitz HJ (2002) The acidic milieu of the horny layer: new findings on the physiology and pathophysiology of skin pH. Am J Clin Dermatol Res 3:261–27210.2165/00128071-200203040-00004 ↗
14. Patel ND, Ward RD, Calle J, Remer EM, Monga M (2017) Vascular disease and kidney stones: abdominal aortic calcifications are associated with low urine ph and hypocitraturia. J Endourol 31:956–96110.1089/end.2017.0350 ↗
15. Stickler DJ (2014) Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done. J Intern Med 276:120–12910.1111/joim.12220 ↗
16. Manissorn J, Fong-ngern K, Peerapen P, Thongboonkerd V (2017) Systematic evaluation for effects of urine pH on calcium oxalate crystallization, crystal-cell adhesion and internalization into renal tubular cells. Scientific Reports, Article Number: 179810.1038/s41598-017-01953-4 ↗
17. Parmenter BH, Slater GJ, Frassetto LA (2017) Spot-testing urine pH, a novel dietary biomarker? A randomised cross-over trial. Nutr Dietics 74:313–31910.1111/1747-0080.12325 ↗
18. Santos L, Neto JP, Crespo A, Nunes D, Costa N, Fonseca IM, Barquinha P, Silva J, Fortunato Martins RE, Pereira L (2014) WO3 nanoparticle-based conformable pH sensor. ACS Appl Mater Interfaces 6:12226–1223410.1021/am501724h ↗
19. Qingwen L, Yiming W, Guoan L (1999) pH-response of nanosized MnO2 prepared with solid state reaction route at room temperature. Sens Actuators B 59:42–4710.1016/S0925-4005(99)00189-6 ↗
20. Sardarinejad A, Maurya D, Alameh K (2015) The pH sensing properties of RF sputtered RuO2 thin-film prepared using different Ar/O2 flow ratio. Materials 8:3352–336310.3390/ma8063352 ↗
21. Huang WD, Cao H, Deb S, Chiao M, Chiao JCA (2011) Flexible pH sensor based on the iridium oxide sensing film. Sens Actuators A 169:1–1110.1016/j.sna.2011.05.016 ↗
22. Maiolo L, Mirabella S, Maita F, Alberti A, Minotti A, Strano V, Pecora A, Shacham-Diamand Y, Fortunato G (2014) Flexible pH sensors based on polysilicon thin film transistors and ZnO nanowalls. Appl Phys Lett 105:09350110.1063/1.4894805 ↗
23. Salvo P, Calisi N, Melai B, Cortigiani B, Mannini M, Caneschi A, Lorenzetti G, Paoletti C, Lomonaco T, Paolicchi A, Scataglini I, Dini V, Romanelli M, Fuoco R, Di Francesco F (2017) Temperature and pH sensors based on graphenic materials. Biosens Bioelectron 91:870–87710.1016/j.bios.2017.01.062 ↗
24. Yang J, Kwak TJ, Zhang X, McClain R, Chang W-J, Gunasekaran S (2016) Digital pH test strips for in-field pH monitoring using iridium oxide-reduced graphene oxide hybrid thin films. ACS Sens 1:1235–124310.1021/acssensors.6b00385 ↗
25. Lafitte VGH, Wang WX, Yashina AS, Lawrence NS (2008) Anthraquinone–ferrocene film electrodes: utility in pH and oxygen sensing. Electrochem Commun 12:1831–183410.1016/j.elecom.2008.09.031 ↗
26. Streeter I, Leventis HC, Wildgoose GG, Pandurangappa M, Lawrence NS, Jiang L, Jones TG, Compton RG (2004) A sensitive reagentless pH probe with a ca. 120 mV/pH unit response. J Solid State Electrochem 8:718–72110.1007/s10008-004-0536-7 ↗
27. Xiong L, Batchelor-McAuley C, Compton RG (2011) Calibrationless pH sensors based on nitrosophenyl and ferrocenyl co-modified screen printed electrodes. Sens Actuators B 159:251–25510.1016/j.snb.2011.06.082 ↗
28. Anderson A, Phair J, Benson J, Meenan BJ, Davis J (2014) Investigating the use of endogenous quinoid moieties on carbon fibre as means of developing micro pH sensors. Mater Sci Eng C 43:533–53710.1016/j.msec.2014.07.038 ↗
29. Phair J, Davis J, Leach C, Cardosi MF (2013) Atmospheric pressure plasma treated carbon fibre weave: a flexible approach to wound monitoring. Electrochem Commun 33:99–10110.1016/j.elecom.2013.04.024 ↗
30. Phair J, Benson J, McCormac C, Cundell J, Gracheva S, Wilkinson D, Forsythe S, Davis J (2014) Butyl grafted polyethylene films doped with carbon black: a foundation for the development of smart bandages. Sens Actuators B 193:764–76910.1016/j.snb.2013.12.014 ↗
31. Nyein HYY, Gao W, Shahpar Z, Emaminejad S, Challa S, Chen K, Fahad HM, Tai L-C, Ota H, Davis RW, Javey A (2016) A wearable electrochemical platform for noninvasive simultaneous monitoring of Ca2+ and pH. ACS Nano 10:7216–722410.1021/acsnano.6b04005 ↗
32. Nakata S, Arie T, Akita S, Takei K (2017) Wearable, Flexible, and multifunctional healthcare device with an ISFET chemical sensor for simultaneous sweat pH and skin temperature monitoring. ACS Sens 2:443–44810.1021/acssensors.7b00047 ↗
33. Jin J, Lin Y, Song M, Gui C, Leesirisan S (2013) Enhancing the electrical conductivity of polymer composites. Eur Polym J 49:1066–107210.1016/j.eurpolymj.2013.01.014 ↗
34. Valipour A, Roushani M (2017) Using silver nanoparticle and thiol graphene quantum dots nanocomposite as a substratum to load antibody for detection of hepatitis C virus core antigen: electrochemical oxidation of riboflavin was used as redox probe. Biosens Bioelectron 89:946–95110.1016/j.bios.2016.09.086 ↗
35. Casimero C, McConville A, Fearon JJ, Lawrence CL, Taylor CM, Smith RB, Davis J (2018) Sensor systems for bacterial reactors: a new flavin-phenol composite film for the in situ voltammetric measurement of pH. Anal Chim Acta 1027:1–810.1016/j.aca.2018.04.053 ↗
36. Hegarty C, Kirkwood S, Cardosi MF, Lawrence CL, Taylor CM, Smith RB, Davis J (2018) Disposable solid state pH sensor based on flavin polymer-ferrocyanide redox couples. Microchem J 139:210–21510.1016/j.microc.2018.02.024 ↗
37. Roushani M, Abdi Z (2014) Novel electrochemical sensor based on graphene quantum dots/riboflavin nanocomposite for the detection of persulfate. Sens Actuators B 201:503–51010.1016/j.snb.2014.05.054 ↗
38. Bejugam M, Sewitz S, Shirude PS, Rodriguez R, Shahid R, Balasubramanian S (2007) Trisubstituted isoalloxazines as a new class of g-quadruplex binding ligands: small molecule regulation of c-kit oncogene expression. J Am Chem Soc 129:12926–1292710.1021/ja075881p ↗