Synergistic effect of carbon microstructure and topography of TiO2 nanorod arrays on hemocompatibility of carbon/TiO2 nanorod arrays composites
Source abstract
Abstract
This study systematically investigated the synergistic effect of material’s surface topography and electronic structure on fibrinogen adsorption and platelet activation. Three kinds of oriented TiO2 nanorod arrays (TNA) were synthesized by the hydrothermal method by changing the growth parameters in order to adjust the surface topography and roughness. The carbon thin films with various sp3 C contents were deposited onto the top of TNA with the DC magnetic-filtered cathodic vacuum arc deposition. The structure, the surface topography, and the roughness of TNA were characterized by X-ray diffraction, scanning electron microscopy, and atomic force microscopy, respectively. The sp3 C content in carbon films was estimated using Raman spectroscopy. The results demonstrated that the amount of fibrinogen adsorbed on surface was influenced merely by surface topography and roughness of TNA, but independent of surface carbon coating. In addition, the platelet adhesion decreased significantly with the increase of the sp3 C content in carbon coating at the same degree of roughness or adsorbed fibrinogen. The lowest platelet adhesion and activation was observed on the specific surface topography associated with the highest sp3 C content in carbon coating.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Electrospun Nanofibers in Biomedical Applications · Polymer Nanocomposite Synthesis and Irradiation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Wootton DM, Ku DN (1999) Fluid mechanics of vascular systems, diseases, and thrombosis. Annu Rev Biomed Eng 1:299–32910.1146/annurev.bioeng.1.1.299 ↗
2. Gorbet MB, Sefton MV (2004) Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytes. Biomaterials 25:5681–570310.1016/j.biomaterials.2004.01.023 ↗
3. Evans-Nguyen KM, Fuierer RR, Fitchett BD, Tolles LR, Conboy JC, Schoenfisch MH (2006) Changes in adsorbed fibrinogen upon conversion to fibrin. Langmuir 22:5115–512110.1021/la053070y ↗
4. Mitragotri S, Lahann J (2009) Physical approaches to biomaterial design. Nat Mater 8:15–2310.1038/nmat2344 ↗
5. Ma WJ, Ruys AJ, Mason RS et al (2007) DLC coatings: effects of physical and chemical properties on biological response. Biomaterials 28:1620–162810.1016/j.biomaterials.2006.12.010 ↗
6. Koh LB, Rodriguez I, Venkatraman SS (2010) The effect of topography of polymer surfaces on platelet adhesion. Biomaterials 31:1533–154510.1016/j.biomaterials.2009.11.022 ↗
7. Smith BS, Yoriya S, Grissom L, Grimes CA, Popat KC (2010) Hemocompatibility of titania nanotube arrays. J Biomed Mater Res A 95:350–36010.1002/jbm.a.32853 ↗
8. Scopelliti PE, Borgonovo A, Indrieri M et al (2010) The effect of surface nanometre-scale morphology on protein adsorption. PLoS One 5:e1186210.1371/journal.pone.0011862 ↗
9. Dolatshahi-Pirouz A, Skeldal S, Hovgaard MB et al (2009) Influence of nanoroughness and detailed surface morphology on structural properties and water-coupling capabilities of surface-bound fibrinogen films. J Phys Chem C 113:4406–441210.1021/jp808488f ↗
10. Baurschmidt P, Schaldach M (1977) The electrochemical aspects of the thrombogenicity of a material. J Bioeng 1:261–278
11. Baurschmidt P, Schaldach M (1980) Alloplastic materials for heart-valve prostheses. Med Biol Eng Comput 18:496–50210.1007/BF02443327 ↗
12. Bakir M (2012) Haemocompatibility of titanium and its alloys. J Biomater Appl 27:3–1510.1177/0885328212439615 ↗
13. Tan AW, Pingguan-Murphy B, Ahmad R, Akbar SA (2013) Advances in fabrication of TiO2 nanofiber/nanowire arrays toward the cellular response in biomedical implantations: a review. J Mater Sci 48:8337–835310.1007/s10853-013-7659-0 ↗
14. Banu AS, Prakash T, Devi SV (2013) Interaction of sol–gel derived TiO2- and SiO2-based bionanocomposites with erythrocytes and serum proteins. IET Nanobiotechnol 7:22–2710.1049/iet-nbt.2012.0006 ↗
15. Li J, Zhu W, Liu J et al (2012) The hemocompatibility and the reabsorption function of TiO2 nanotubes biomembranes. Chin Sci Bull 57:2022–202810.1007/s11434-012-5038-x ↗
16. Chen HL, Luo P, Huang ZY et al (2013) Preparation and blood compatibility of carbon/TiO2 nanocomposite. Diam Relat Mater 38:52–5810.1016/j.diamond.2013.06.011 ↗
17. Liu B, Aydil ES (2009) Growth of oriented single-crystalline rutile TiO2 nanorods on transparent conducting substrates for dye-sensitized solar cells. J Am Chem Soc 131:3985–399010.1021/ja8078972 ↗
18. Oberlander S, Xie T, Chandrachud U, Gal S (2010) Scintillation proximity assay for total p53 protein as an alternative to ELISA. J Immunol Methods 360:173–17710.1016/j.jim.2010.06.018 ↗
19. Huang Z, Luo P, Chen M, Pan S, Chen D (2011) Microstructure and hemocompatibility of neodymium doped zinc oxide thin films. Mater Lett 65:2345–234710.1016/j.matlet.2011.05.031 ↗
20. Wei Z, Li R, Huang T, Yu A (2011) Fabrication of morphology controllable rutile TiO2 nanowire arrays by solvothermal route for dye-sensitized solar cells. Electrochim Acta 56:7696–770210.1016/j.electacta.2011.06.038 ↗
21. Casiraghi C, Ferrari A, Robertson J (2005) Raman spectroscopy of hydrogenated amorphous carbons. Phys Rev B 72:085401–08541410.1103/PhysRevB.72.085401 ↗
22. Chhowalla M, Ferrari A, Robertson J, Amaratunga G (2000) Evolution of sp2 bonding with deposition temperature in tetrahedral amorphous carbon studied by Raman spectroscopy. Appl Phys Lett 76:1419–142110.1063/1.126050 ↗
23. Rodil S, Ferrari A, Robertson J, Milne W (2001) Raman and infrared modes of hydrogenated amorphous carbon nitride. J Appl Phys 89:5425–543010.1063/1.1365076 ↗
24. Ferrari A, Robertson J (2000) Interpretation of Raman spectra of disordered and amorphous carbon. Phys Rev B 61:14095–1410610.1103/PhysRevB.61.14095 ↗
25. Polo M, Andujar J, Hart A, Robertson J, Milne W (2000) Preparation of tetrahedral amorphous carbon films by filtered cathodic vacuum arc deposition. Diam Relat Mater 9:663–66710.1016/S0925-9635(99)00339-8 ↗
26. Valentini L, Kenny J, Mariotto G et al (2001) Ar-dilution effects on the elastic and structural properties of hydrogenated hard carbon films deposited by plasma-enhanced chemical vapor deposition. Diam Relat Mater 10:1088–109210.1016/S0925-9635(00)00391-5 ↗
27. Chen D, Wei A, Wong S, Peng S, Xu J, Wilson I (1999) Synthesis and microstructural properties of tetrahedral amorphous carbon films. J Non Cryst Solids 254:161–16610.1016/S0022-3093(99)00389-0 ↗
28. Abraham GA, de Queiroz AA, Román JS (2001) Hydrophilic hybrid IPNs of segmented polyurethanes and copolymers of vinylpyrrolidone for applications in medicine. Biomaterials 22:1971–198510.1016/S0142-9612(00)00381-1 ↗
29. Ishihara K, Fukumoto K, Iwasaki Y, Nakabayashi N (1999) Modification of polysulfone with phospholipid polymer for improvement of the blood compatibility. Part 2. Protein adsorption and platelet adhesion. Biomaterials 20:1553–155910.1016/S0142-9612(98)00206-3 ↗
30. Iwasaki Y, Ishihara K (2005) Phosphorylcholine-containing polymers for biomedical applications. Anal Bioanal Chem 381:534–54610.1007/s00216-004-2805-9 ↗
31. Hylton DM, Shalaby SW, Latour RA (2005) Direct correlation between adsorption-induced changes in protein structure and platelet adhesion. J Biomed Mater Res A 73:349–35810.1002/jbm.a.30295 ↗
32. Sivaraman B, Latour RA (2010) The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogen. Biomaterials 31:832–83910.1016/j.biomaterials.2009.10.008 ↗
33. Bolz A, Schaldach M (1992) Physikalische mechanismen der festkörper-protein-wechselwirkung an der phasengrenze a-SiC: H-fibrinogen-physical mechanisms of solid-protein interactions at the interface between amorphous silicon carbide and fibrinogen. Biomed Tech/Biomed Eng 37:244–25310.1515/bmte.1992.37.11.244 ↗
34. Maitz MF, Pham M-T, Wieser E, Tsyganov I (2003) Blood compatibility of titanium oxides with various crystal structure and element doping. J Biomater Appl 17:303–31910.1177/0885328203017004005 ↗
35. Huang N, Yang P, Leng Y et al (2003) Hemocompatibility of titanium oxide films. Biomaterials 24:2177–218710.1016/S0142-9612(03)00046-2 ↗
36. Liu Y, Li Z, He Z et al (2007) Structure and blood compatibility of tetrahedral amorphous hydrogenated carbon formed by a magnetic-field-filter plasma stream. Surf Coat Technol 201:6851–685610.1016/j.surfcoat.2006.09.021 ↗
37. Robertson J (2003) Electronic and atomic structure of diamond-like carbon. Semicond Sci Technol 18:S12–S1910.1088/0268-1242/18/3/302 ↗
38. da Silva DS, Côrtes ADS, Oliveira MH et al (2011) Application of amorphous carbon based materials as antireflective coatings on crystalline silicon solar cells. J Appl Phys 110:043510–04351810.1063/1.3622515 ↗