journal article·2011-09

Fracture analysis of ceramic femoral head in hip arthroplasty based on microdamage monitoring using acoustic emission

Yukiya Yamada, Shuichi Wakayama, Junji Ikeda, Fumiaki Miyaji

Journal of Materials Science· Volume 46· Issue 18
Publisher page

Abstract

Damage accumulation during compression testing of the alumina femoral head used in hip arthroplasty was monitored using an acoustic emission (AE) technique. Because a number of mechanical noises due to friction disturbed the AE measurement during the test using a conventional testing configuration standardized in ISO 7206, the testing apparatus was modified so that AE signals from microdamage were detected successfully. During the compression tests of femoral heads, a rapid increase in AE energy was observed before the final fracture. Dye penetration observations demonstrated that the rapid increase in AE energy correlated with the formation of maincrack which leads to the final fracture. The stress distribution in femoral heads was analyzed using finite element analysis (FEA). The critical stress for maincrack formation and the final fracture strength were determined. Finally, fundamental insights into the development of a technique for assessing the long-term reliability of ceramic femoral heads were obtained.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced X-ray and CT Imaging · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. Hench LL (1993) Bioceramics. J Amer Ceram Soc 81:170510.1111/j.1151-2916.1998.tb02540.x ↗
2. Hench LL, Wilson J (1993) An introduction to bioceramics. World Scientific, Singapore10.1142/2028 ↗
3. Clarke IC et al (2003) J Bone Joint Surg 85-A:7310.2106/00004623-200300004-00009 ↗
4. Evans AG (1972) J Mater Sci 7:1137. doi: https://doi.org/10.1007/BF0055019610.1007/BF00550196 ↗
5. Evans AG, Linzer M (1973) J Amer Ceram Soc 56:57510.1111/j.1151-2916.1973.tb12419.x ↗
6. Davidge RW, McLaren JR, Tappin G (1973) J Mater Sci 8:1699. doi: https://doi.org/10.1007/BF0240351910.1007/BF02403519 ↗
7. Evans AG, Wiederhorn SM (1974) Int Jour Fracture 10:37910.1007/BF00035499 ↗
8. Ritter JE Jr, Oates PB, Fuller ER Jr, Wiederhorn SM (1980) J Mater Sci 15:2275. doi: https://doi.org/10.1007/BF0055231710.1007/BF00552317 ↗
9. Fuller ER Jr, Wiederhorn SM, Ritter JE Jr, Oates PB Jr, Wiederhorn SM, Ritter JE Jr, Oates PB (1980) J Mater Sci 15:2282. doi: https://doi.org/10.1007/BF0055231810.1007/BF00552318 ↗
10. Weisse B, Affolter C, Koller RE, Stutz A (2010) Proc IMechE Part H 224:1051
11. Wakayama S, Koji T, Nishimura H (1991) Trans Jap Soc Mech Eng 57:50410.1299/kikaia.57.504 ↗
12. Wakayama S, Nishimura H (1992) In: Fracture mechanics of ceramics, vol 10. Plenum Publishing Co., New York10.1007/978-1-4615-3348-1_4 ↗
13. Wakayama S, Ikeda C, Ikeda J (2006) J Acoustic Emission 24:228
14. ISO-7206-10, Implants for surgery—Partial and total hip-joint prosthesis—Part 10: determination of resistance to static load of modular femoral head
15. Wakayama S, Horide A, Kawahara M (1999) In: Proceedings of the 12th International conference on composite materials (CD-ROM), Paris
16. Horide A, Wakayama S, Kawahara M (1999) Adv Compos Mater 8:13910.1163/156855199X00155 ↗
17. Weibull W (1951) J Appl Mech 18:29310.1115/1.4010337 ↗
18. FDA Guidance (draft), Guidance Document for the Preparation of Premarket Notification for Ceramic Ball Hip System