Characterization of anodic oxide layer on Ti-6Al-7Nb alloy obtained via electrochemical anodization process: microstructure, topography, and corrosion properties
Source abstract
Abstract
Titanium and its alloys are currently among the most preferred materials for bone implants due to their excellent biocompatibility and mechanical properties. A major challenge, however, is surface structure design that enhances tissue integration. This study presents preliminary results on the surface modification of Ti-6Al-7Nb alloy using electrochemical anodization - anodic oxidation (AO) and micro-arc oxidation (MAO). The goal was to compare the morphology, composition, and corrosion behaviour of formed oxide layers using electron and X-ray sources methodologies and corrosion resistance, evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy. Analyses indicated a self-organized nanotubular structure on anodized surfaces and a vermiform morphology on MAO-treated ones. The presence of amorphous TiO2 and Ti-α phases, with aluminium and niobium distributed in both oxide layers, has been also determined. Corrosion testing showed that both anodization processes improved the protective properties of the alloy. MAO coatings exhibited slightly higher polarization resistance compared to AO surfaces (superior corrosion protection). These results enhance understanding of how electrochemical surface treatments influence the microstructure and corrosion behaviour of titanium-based biomaterials. The findings are particularly relevant for the less-studied Ti-6Al-7Nb alloy and provide a foundation for optimizing surface engineering methods to improve implant performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Tomashov ND, Altovsky RM, Chernova GP (1961) Passivity and corrosion resistance of titanium and its alloys. J Electrochem Soc 108(2):113. https://doi.org/10.1149/1.242802310.1149/1.2428023 ↗
2. Lütjering, G.Williams J C, Gysler A (2000) Microstructure and mechanical properties of titanium alloys. https://doi.org/10.1142/9789812793959_0001.10.1142/9789812793959_0001 ↗
3. Leyens, C, Peters M (2003) Titanium and titanium alloys: fundamentals and applications. https://doi.org/10.1002/3527602119.10.1002/3527602119 ↗
4. Besisa N Yajima T (2024) Titanium-based alloys: classification and diverse applications. https://doi.org/10.5772/intechopen.1005269.10.5772/intechopen.1005269 ↗
5. Abdel-Hady Gepreel M, Niinomi M (2013) Biocompatibility of Ti-alloys for long-term implantation. J Mech Behav Biomed Mater 20:407–415. https://doi.org/10.1016/j.jmbbm.2012.11.01410.1016/j.jmbbm.2012.11.014 ↗
6. Teixeira J, Santos A, Pinto B, Capelin G, Pintão C, Correa D, Grandini C, Lisboa-Filho P (2024) Tribological behavior study of new titanium alloys for biomedical applications. Proc Inst Mech Eng Part J: J Eng Tribol. https://doi.org/10.1177/1350650124130648310.1177/13506501241306483 ↗
7. Elias C, Lima J, Valiev R (2008) Biomedical applications of titanium and its alloys. JOM: J Miner Metals Mater Soc 60:46–49. https://doi.org/10.1007/s11837-008-0031-110.1007/s11837-008-0031-1 ↗
8. Kaur M, Singh K (2019) Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. Mater Sci Eng: C 102(844):862. https://doi.org/10.1016/j.msec.2019.04.06410.1016/j.msec.2019.04.064 ↗
9. Zhang L, Chen L (2019) A review on biomedical titanium alloys: recent progress and prospect. Adv Eng Mater. https://doi.org/10.1002/adem.20180121510.1002/adem.201801215 ↗
10. Bahl S, Aleti BT, Suwas S, Chatterjee K (2018) Surface nanostructuring of titanium imparts multifunctional properties for orthopedic and cardiovascular applications. Mater Des 144(169):181. https://doi.org/10.1016/j.matdes.2018.02.02210.1016/j.matdes.2018.02.022 ↗
11. Marin E, Lanzutti A (2023) Biomedical applications of titanium alloys: a comprehensive review. Materials (Basel, Switzerland). https://doi.org/10.3390/ma1701011410.3390/ma17010114 ↗
12. Mohamed LZ, Abd Elmomen SS, El-Hadad S (2022) Investigating the thermal oxidation behavior of Ti–6Al–7Nb alloy in dry air. Mater Corros. https://doi.org/10.1002/maco.20211295710.1002/maco.202112957 ↗
13. Assis SL, Costa I (2007) Electrochemical evaluation of Ti-13Nb-13Zr, Ti-6Al-4V and Ti-6Al-7Nb alloys for biomedical application by long-term immersion tests. Mater Corros 58(5):329–333. https://doi.org/10.1002/maco.20060402710.1002/maco.200604027 ↗
14. Al-Mobarak NA, Al-Swayih AA, Al-Rashoud FA (2011) Corrosion behavior of Ti-6Al-7Nb alloy in biological solution for dentistry applications. Int J Electrochem Sci 6:2031–2042. https://doi.org/10.1016/S1452-3981(23)18165-X10.1016/S1452-3981(23)18165-X ↗
15. Hussain SA, Syed R, Uprendra CS (2023) Multi Wear Response Optimization of Ti-6Al-7Nb Biomedical Alloy. Int J Innov Technol Explor Eng. 12(19):25. https://doi.org/10.35940/ijitee.B9409.011222310.35940/ijitee.B9409.0112223 ↗
16. Posiyano K, Raghupatruni P, Dzogbewu TC, Olakanmi E, Leso T, Setswalo K, Sello A (2024) The potential of Ti-6Al-7Nb, and design for manufacturing considerations in mitigating failure of hip implants in service. Biomed Eng Adv 8:100136. https://doi.org/10.1016/j.bea.2024.10013610.1016/j.bea.2024.100136 ↗
17. Xu Y, Xiao Y, Yi D, Liu H, Wu L, Wen J (2015) Corrosion behavior of Ti–Nb–Ta–Zr–Fe alloy for biomedical applications in Ringer’s solution. Trans Nonferrous Met Soc China 25(8):2556–2563. https://doi.org/10.1016/s1003-6326(15)63875-410.1016/s1003-6326(15)63875-4 ↗
18. Madane Mr. (2025). Nanotechnology. International Journal for Research in Applied Science and Engineering Technology. 13 2748 2753 https://doi.org/10.22214/ijraset.2025.68756.10.22214/ijraset.2025.68756 ↗
19. Chen X, Mao SS (2007) Titanium dioxide nanomaterials: synthesis, properties, modifications, and applications. Chem Rev 107(7):2891–2959. https://doi.org/10.1021/cr050053510.1021/cr0500535 ↗
20. Indira K, Mudali UK, Nishimura T, Rajendran N (2015) A review on TiO2 nanotubes: influence of anodization parameters, formation mechanism, properties, corrosion behavior, and biomedical applications. J Bio- Tribo-Corros. https://doi.org/10.1007/s40735-015-0024-x10.1007/s40735-015-0024-x ↗
21. Maruyama T, Arai S (1992) Titanium dioxide thin films prepared by chemical vapor deposition. Solar Energy Mater Solar Cells 26(4):323–329. https://doi.org/10.1016/0927-0248(92)90051-p10.1016/0927-0248(92)90051-p ↗
22. Chigane M, Shinagawa T, Tani J (2017) Preparation of titanium dioxide thin films by indirect-electrodeposition. Thin Solid Films 628:203–207. https://doi.org/10.1016/j.tsf.2017.03.03110.1016/j.tsf.2017.03.031 ↗
23. Ou H, Lo S (2007) Review of titania nanotubes synthesized via the hydrothermal treatment: fabrication, modification, and application. Sep Purif Technol 58(1):179–191. https://doi.org/10.1016/j.seppur.2007.07.01710.1016/j.seppur.2007.07.017 ↗
24. Ullattil S G, Periyat P (2017) Sol-Gel Synthesis of Titanium Dioxide. In: Sol-Gel Materials for Energy, Environment and Electronic Applications. 271–283 https://doi.org/10.1007/978-3-319-50144-4_9.10.1007/978-3-319-50144-4_9 ↗
25. Veselinov D, Skulev H (2020) Influence of the electrochemical anodizing parameters on the microstructure, microroughness and microhardness of anodized Ti-6Al-7Nb. Arch Metall Mater. https://doi.org/10.24425/amm.2020.133242.10.24425/amm.2020.133242 ↗
26. Yang B (2004) Preparation of bioactive titanium metal via anodic oxidation treatment. Biomaterials 25(6):1003–1010. https://doi.org/10.1016/s0142-9612(03)00626-410.1016/s0142-9612(03)00626-4 ↗
27. Ghicov A, Schmuki P (2009) Self-ordering electrochemistry: a review on growth and functionality of TiO2 nanotubes and other self-aligned MOx structures. Chem Commun 20:2791. https://doi.org/10.1039/b822726h10.1039/b822726h ↗
28. Huang H-H, Wu C-P, Sun Y-S, Yang W-E, Lee T-H (2014) Surface nanotopography of an anodized Ti–6Al–7Nb alloy enhances cell growth. J Alloy Compd 615:S648–S654. https://doi.org/10.1016/j.jallcom.2013.12.2310.1016/j.jallcom.2013.12.23 ↗
29. Ulfah I, Bachtiar BM, Murnandityas A, Slamet S (2018) Synthesis and characterization of Ag-doped TiO2 nanotubes on Ti-6Al-4V and Ti-6Al-7Nb alloy. AIP Conf Proc 1964:020008. https://doi.org/10.1063/1.503829010.1063/1.5038290 ↗
30. Macak JM, Tsuchiya H, Ghicov A, Yasuda K, Hahn R, Bauer S, Schmuki P (2007) TiO2 nanotubes: self-organized electrochemical formation, properties and applications. Curr Opin Solid State Mater Sci 11(1–2):3–18. https://doi.org/10.1016/j.cossms.2007.08.00410.1016/j.cossms.2007.08.004 ↗
31. Ming X, Wu Y, Zhang Z, Li Y (2023) Micro-arc oxidation in titanium and its alloys: development and potential of implants. Coatings 13:2064. https://doi.org/10.3390/coatings1312206410.3390/coatings13122064 ↗
32. Cimenoglu H, Gunyuz M, Kose GT, Baydogan M, Uğurlu F, Sener C (2011) Micro-arc oxidation of Ti6Al4V and Ti6Al7Nb alloys for biomedical applications. Mater Charact 62(3):304–311. https://doi.org/10.1016/j.matchar.2011.01.00210.1016/j.matchar.2011.01.002 ↗
33. K N Qabas, M S Jassim M D Nawal (2023) Micro-arc oxidation enhances mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy. 3C Tecnología. Glosas de innovación aplicada a la pyme. 12 1 262 280 https://doi.org/10.17993/3ctecno.2023.v12n1e43.262-280.10.17993/3ctecno.2023.v12n1e43.262-280 ↗
34. Zhai D, Qiu T, Shen J et al (2022) Growth kinetics and mechanism of microarc oxidation coating on Ti−6Al−4V alloy in phosphate/silicate electrolyte. Int J Miner Metall Mater 29:1991–1999. https://doi.org/10.1007/s12613-022-2413-810.1007/s12613-022-2413-8 ↗
35. Li G, Ma F, Liu P, Qi S, Li W, Zhang K, Chen X (2023) Review of micro-arc oxidation of titanium alloys: mechanism, properties and applications. J Alloys Compd 948:169773. https://doi.org/10.1016/j.jallcom.2023.16977310.1016/j.jallcom.2023.169773 ↗
36. Kaseem M, Fatimah S, Nashrah N, Gun Ko Y (2021) Recent progress in surface modification of metals coated by plasma electrolytic oxidation: Principle, structure, and performance. Prog Mater Sci 117:100735. https://doi.org/10.1016/j.pmatsci.2020.10073510.1016/j.pmatsci.2020.100735 ↗
37. Bazaglia Kuroda PA, Rossi MC, Grandini CR, Moreira Afonso CR (2023) Assessment of applied voltage on the structure, pore size, hardness, elastic modulus, and adhesion of anodic coatings in Ca-, P-, and Mg-rich produced by MAO in Ti–25Ta–Zr alloys. J Mark Res 26(4656):4669. https://doi.org/10.1016/j.jmrt.2023.08.16510.1016/j.jmrt.2023.08.165 ↗
38. Trelka-Druzic A, Muhaffel F, Wojtas D, Jarzębska A, Cempura G, Kulczyk M, Goldbergova MP, Maj L (2025) Low-voltage micro-arc oxidation of plastically deformed titanium in silicate-based electrolytes: microstructure, tribological properties and cytocompatibility. Ceram Int. https://doi.org/10.1016/j.ceramint.2025.10.2710.1016/j.ceramint.2025.10.27 ↗
39. Safwat EM, Abdel-Gawad SA, Shoeib MA et al (2024) Electrochemical anodization of cast titanium alloys in oxalic acid for biomedical applications. Front Chem Sci Eng 18:2. https://doi.org/10.1007/s11705-023-2368-y10.1007/s11705-023-2368-y ↗
40. Hammam RE, Safwat EM, Abdel-Gawad SA, Shoeib M, El-Hadad S (2024) Influence of anodization conditions on deposition of hydroxyapatite on α/β Ti alloys for osseointegration: atomic force microscopy analysis. Trans Nonferr Metals Soc China. 34(11):3629–3649. https://doi.org/10.1016/S1003-6326(24)66630-610.1016/S1003-6326(24)66630-6 ↗
41. Moskalewicz T, Kruk A, Kot M, Kayali S, Czyrska-Filemonowicz A (2014) Characterization of microporous oxide layer synthesized on Ti–6Al–7Nb alloy by micro-arc oxidation. Arch Civ Mech Eng 14(3):370–375. https://doi.org/10.1016/j.acme.2013.09.00210.1016/j.acme.2013.09.002 ↗
42. Liu ZF, Wang WQ, Qi M (2013) A porous TiO2 coating with vermiform morphology formed on Ti through micro-arc oxidation. Adv Mater Res 652:1818–1821. https://doi.org/10.4028/www.scientific.net/amr.652-654.181810.4028/www.scientific.net/amr.652-654.1818 ↗
43. Fazel M, Salimijazi HR, Golozar MA, Garsivaz jazi MR (2015) A comparison of corrosion, tribocorrosion and electrochemical impedance properties of pure Ti and Ti6Al4V alloy treated by micro-arc oxidation process. Appl Surf Sci 324:751–756. https://doi.org/10.1016/j.apsusc.2014.11.03010.1016/j.apsusc.2014.11.030 ↗
44. Rafieerad AR, Zalnezhad E, Bushroa AR, Hamouda AM, Sarraf M, Nasiri-Tabrizi B (2015) Self-organized TiO2 nanotube layer on Ti–6Al–7Nb for biomedical application. Surf Coat Technol 265(24):31. https://doi.org/10.1016/j.surfcoat.2015.01.06710.1016/j.surfcoat.2015.01.067 ↗
45. Murray JA, Wriedt HA (1994) In: Boyer RR, Welsch G, Collings (eds), Materials properties handbook: titanium alloys. Ohio: ASM International.
46. Hu Y, Wang Z, Ai J, Bu S, Liu H (2021) Preparation of coating on the titanium surface by micro-arc oxidation to improve corrosion resistance. Coatings 11:230. https://doi.org/10.3390/coatings1102023010.3390/coatings11020230 ↗
47. Shi X, Xu L, Wang Q (2010) Porous TiO2 film prepared by micro-arc oxidation and its electrochemical behaviors in Hank’s solution. Surf Coat Technol 205(6):1730–1735. https://doi.org/10.1016/j.surfcoat.2010.09.05810.1016/j.surfcoat.2010.09.058 ↗
48. Cotolan N, Pop A, Marconi D, Ponta O, Muresan L (2015) Corrosion behavior of TiO2-coated Ti–6Al–7Nb surfaces obtained by anodic oxidation in sulfuric or acetic acid. Mater Corros 66:635–642. https://doi.org/10.1002/maco.20140768710.1002/maco.201407687 ↗
49. Ali Yahia SA, Hamadou L, Kadri A, Benbrahim N, Sutter EMM (2012) Effect of anodizing potential on the formation and EIS characteristics of TiO2nanotube arrays. J Electrochem Soc 159(4):K83–K92. https://doi.org/10.1149/2.077204jes10.1149/2.077204jes ↗
50. Lazanas AC, Prodromidis MI (2023) Electrochemical Impedance Spectroscopy–a tutorial. ACS Measure Sci Au 3(3):162–193. https://doi.org/10.1021/acsmeasuresciau.2c0007010.1021/acsmeasuresciau.2c00070 ↗
51. Yang J, Song Y, Dong K, Han E-H (2023) Research progress on the corrosion behavior of titanium alloys. Corros Rev 41(1):5–20. https://doi.org/10.1515/corrrev-2022-003110.1515/corrrev-2022-0031 ↗
52. Rafieerad AR, Bushroa AR, Zalnezhad E, Sarraf M, Basirun WJ, Baradaran S, Nasiri-Tabrizi B (2015) Microstructural development and corrosion behavior of self-organized TiO2 nanotubes coated on Ti–6Al–7Nb. Ceram Int 41(9):10844–10855. https://doi.org/10.1016/j.ceramint.2015.05.025.4110.1016/j.ceramint.2015.05.025.41 ↗
53. González JE, Mirza-Rosca J (1999) Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications. J Electroanal Chem 471(2):109–115. https://doi.org/10.1016/s0022-0728(99)00260-010.1016/s0022-0728(99)00260-0 ↗
54. Lavos-Valereto IC, Wolynec S, Ramires I, Guastaldi AC, Costa I (2004) Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti–6Al–7Nb alloy in Hank’s solution. J Mater Sci Mater Med 15(1):55–59. https://doi.org/10.1023/b:jmsm.0000010097.862.10.1023/b:jmsm.0000010097.862. ↗
55. Gnedenkov SV, Sinebryukhov SL (2005) Electrochemical impedance spectroscopy of oxide layers on the titanium surface. Russ J Electrochem 41:858–865. https://doi.org/10.1007/s11175-005-0145-510.1007/s11175-005-0145-5 ↗
56. Pesode P, Barve S (2024) A grey relational analysis of the micro arc oxidation process parameters and their effects on Ti-6Al-7Nb coating performance and corrosion resistance for biomedical uses. Eng Res Express. https://doi.org/10.1088/2631-8695/ad82a210.1088/2631-8695/ad82a2 ↗
57. Paszenda Z, Walke W, Jadacka S (2010) Electrochemical investigations of Ti6Al4V and Ti6Al7Nb alloys used on implants in bone surgery. J Achiev Mater Manuf Eng. 38(1):24–32