journal article·2014-02

The effect of fibrous reinforcement on optical and impact performance of fibre-reinforced transparent glass composites

M. H. Akonda, B. K. Kandola, A. R. Horrocks, P. Myler

Journal of Materials Science· Volume 49· Issue 4
Publisher page

Abstract

Fire-resistant laminated glass composite containing intumescent silicate as an interlayer between two glass sheets is a widely used transparent building material. To improve the impact and other mechanical properties of this composite structure, a transparent silicate matrix has been reinforced with alkali- and UV-resistant synthetic (polypropylene, polyamide 66, glass) and metallic (steel) fibres as of nonwoven webs or woven meshes. The refractive indices (RIs) of the fibres and the matrices were measured and the transparency of the laminated composites depended upon fibre RI as well as reinforcement structure. All fibres were successful in significantly enhancing impact properties of laminated glass composites with alkali-resistant glass fibres showing the best performance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Analysis of Composite Materials · Fire effects on concrete materials · Glass properties and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Donal IW (1995) Preparation, properties and applications of glass and glass–ceramic matrix composites. Key Eng Mater 108–110:123–14410.4028/www.scientific.net/KEM.108-110.123 ↗
2. Iba H, Chang T, Kagawa Y (1997) Optomechanical fibre reinforced glass matrix composite: fabrication and properties. Ceram Eng Sci Proc 18(3):787–92310.1002/9780470294437.ch86 ↗
3. Kangutkar P, Cahng T, Kagawa Y, Koczak MJ, Minakuchi H, Kanamaru K (1993) Fabrication of optically transparent SiCaON fibre reinforced glass matrix composites. Ceram Eng Proc 14:96310.1002/9780470314234.ch34 ↗
4. Dericioglu AF, Kagawa Y (2002) Fail-safe light transmitting SiC fibre reinforced spinal matrix optomechanical composite. J Mater Sci 37:523–530. doi: 10.1023/A:101371350675510.1023/A:1013713506755 ↗
5. Sun Y, Singh RN (1996) The fabrication of toughened and transparent glass composite. Ceramic Trans 74:141–151
6. Dericioglu AF, Zhu S, Kagawa Y (2002) Improvement of fracture resistance in a glass matrix optomechanical composite reinforcement by Al2O3–ZrO2 mini-composite. Ceramic Eng Sci 23(3):485–49210.1002/9780470294741.ch57 ↗
7. Boccaccini AR, Atiq S, Helsch G (2003) Optomechanical glass matrix composites. Comp Sci Technol 63:779–78310.1016/S0266-3538(02)00262-2 ↗
8. Fankhanel B, Muller E, Weise K, Marx G (2002) Translucent fibre reinforced glass composite. Key Eng Mater 206–213:1109–111210.4028/www.scientific.net/KEM.206-213.1109 ↗
9. Kim AK, Lougheed GD (1990) The protection of glazing systems with dedicated sprinklers. J Fire Prot Eng 2:49–5910.1177/104239159000200202 ↗
10. Razwick J (1999) The next thousand years fire-rated glazing in the next millennium. U.S. Glass 34(6):1–3
11. Brinkmann N (2000) Generating explosively hot ideas in fire-rated glazing. U.S. Glass. 35(4):1–5
12. Pilkington pyrostop®, Fire-resistant Glass Range (2013). www.pilkington.com
13. Prewo KM, Brennan JJ, Layden K (1986) Fibre reinforced glasses and glass ceramics for high performance applications. Ceram Bull 65:305–322
14. Bulewicz EM, Pelc A, Kozlowski R, Miciukiewicz A (1985) Intumescent silicate-based materials: mechanism of swelling in contact with fire. Fire Mater 9:171–17510.1002/fam.810090405 ↗
15. Iler RK (1979) The chemistry of silica: solubility polymerization, colloid and surface properties and bio-chemistry. Wiley Inter-science, New York
16. Langille KB, Nguyen D, Bernt JO, Veinot DE, Murthy MK (1991) Mechanism of dehydration and intumescence of soluble silicate, Part I: effect of silica to metal oxide molar ratio. J Mater Sci 26:695–703. doi: 10.1007/BF0058830610.1007/BF00588306 ↗
17. Laukaitis A, Keriene J, Mikulskis D, Sinica M, Sezemanas G (2009) Influence of fibrous additives on properties of aerated autoclaved concrete forming mixtures and strength characteristics of products. Constr Build Mater 23(9):3034–304210.1016/j.conbuildmat.2009.04.007 ↗
18. Tanyildizi H (2009) Statistical analysis for mechanical properties of polypropylene fibre reinforced lightweight concrete containing silica fume exposed to high temperature. Mater Des 30(8):3252–325810.1016/j.matdes.2008.11.032 ↗
19. Uygunoglu T (2008) Investigation of microstructure and flexural behaviour of steel fibre reinforced concrete. Mater Str/Materiaux et Constr 41(8):1441–144910.1617/s11527-007-9341-y ↗
20. Algin HM, Turgut P (2008) Cotton and limestone powder wastes as brick material. Constr Build Mater 22(6):1074–108010.1016/j.conbuildmat.2007.03.006 ↗
21. Akonda MH, Kandola BK, Horrocks AR (2012) Effect of alkali and ultraviolet ageing on physical, thermal and mechanical properties of fibres for potential use as reinforcing elements in glass/silicate composites. Polym Adv Tech 23:1454–146310.1002/pat.2067 ↗
22. Hearle JWS, Morton WE (1993) Physical properties of textile fibres, 3rd edn. Pub. Textile Inst, Manchester
23. Stroiber RE, Morse SA (1994) Crystal identification with the polarizing microscope, Chapter 2. Chapman & Hall, London10.1007/978-1-4615-2387-1 ↗
24. Hodgkinson JM (ed) (2000) Mechanical testing of advanced fibre reinforced composites. Chapter six. Woodhead Publishing Ltd, Cambridge
25. Impact performance requirements for flat safety glass and safety plastic for use in buildings. British Standard Hand book, BS 6206:1981; ISBN 0580 124479
26. Laight A, Dear JP, Farmer SJ, Jones CH (1991) Measurement of elastic moduli of composite panels at elevated temperature by vibration excitation. Meas Sci Technol 2:80–98410.1088/0957-0233/2/10/015 ↗
27. Warner SB, Stenquist B (eds) (1995) Fibre Science. Prentice Hall, New Jersey
28. Lewin M, Marcel Pearce E (eds) (1985) Hand book of fibre science and technology—fibre chemistry. Dekker Inc, New York
29. Matveev MA, Rabukin AI (1963) Relationship between the refractive index of water glass and their composition. Glass Ceram 20(5):254–25710.1007/BF00673042 ↗
30. Yakovlev G, Kodolov V (2000) Intumescent fireproof coating based on water glass. Int J Polym Mater 47:107–11510.1080/00914030008033339 ↗
31. Hearle JWS (ed) (2004) High performance fibres. Woodhead Publishing Ltd and CRC Press, Cambridge