journal article·2020-09

Effect of deformed subsurface on the corrosion resistance of biomedical CoCrMo alloy in simulated physiological solution

Zhongwei Wang, Yu Yan, Lijie Qiao

Journal of Materials Science· Volume 55· Issue 27
Publisher page

Abstract

In most cases, the microstructure of implants is stable and changeless after implanted into the body. However, the metallic joint replacements would be worn during patients’ movements. Their subsurface microstructures were deformed and changed. That may affect the corrosion resistance of the joint. Due to the complex surface situation on the worn joints, it was difficult to distinguish and evaluate the influence of the subsurface microstructure from surface roughness, wear debris, etc. In this study, a CoCrMo alloy used for artificial joints was treated by high-energy shot peening method to obtain a similar deformed surface to the worn joints, but without introducing other influencing factors. The corrosion rate of the deformed alloy which was treated for 4 h was down by 93.3% in the phosphate-buffered saline (PBS) solution compared with the untreated alloy. However, with the addition of bovine serum albumin (BSA) into PBS, the treated alloy showed the poorer corrosion resistance when its concentration was equal to or greater than 0.1 μmol L−1. The defects (grain boundaries and stacking faults), which were introduced into the alloy surface during peening process, could accelerate anodic dissolution, improve element diffusion and increase the number of active sites. These were beneficial for forming a more compact and thicker passive film which enhanced the corrosion resistance of the alloy. However, the deformation of subsurface could promote the adsorption of protein on the alloy surface. The adsorbed protein molecules would chelate with metallic ions and weaken the passive film.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Surface Treatment and Residual Stress · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Shih CC, Shih CM, Su YY, Su LHJ, Chang MS, Lin SJ (2004) Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications. Corros Sci 46:427–44110.1016/S0010-938X(03)00148-3 ↗
2. Oskouei RH, Barati MR, Farhoudi H, Taylor M, Solomon LB (2017) A new finding on the in-vivo crevice corrosion damage in a CoCrMo hip implant. Mater Sci Eng C 79:390–39810.1016/j.msec.2017.05.086 ↗
3. Geetha M, Mudali UK, Gogia AK, Asokamani R, Raj B (2004) Influence of microstructure and alloying elements on corrosion behavior of Ti–13Nb–13Zr alloy. Corros Sci 46:877–89210.1016/S0010-938X(03)00186-0 ↗
4. Akonko S, Li DY, Ziomek-Moroz M (2005) Effects of cathodic protection on corrosive wear of 304 stainless steel. Tribol Lett 18:405–41010.1007/s11249-004-3205-1 ↗
5. Li N, Li Y, Wang S, Wang F (2006) Electrochemical corrosion behavior of nanocrystallized bulk 304 stainless steel. Electrochim Acta 52:760–76510.1016/j.electacta.2006.06.023 ↗
6. Zeng P, Rana A, Thompson R, Rainforth WM (2015) Subsurface characterisation of wear on mechanically polished and electro-polished biomedical grade CoCrMo. Wear 332–333:650–66110.1016/j.wear.2015.02.007 ↗
7. Bryant MG, Buente D, Oladokun A, Ward M, Huber G, Morlock M, Neville A (2017) Surface and subsurface changes as a result of tribocorrosion at the stem-neck interface of bi-modular prosthesis. Biotribology 10:1–1610.1016/j.biotri.2017.02.002 ↗
8. Pourzal R, Theissmann R, Williams S, Gleising B, Fisher J, Fischer A (2009) Subsurface changes of a MoM hip implant below different contact zones. J Mech Behav Biomed Mater 2:186–19110.1016/j.jmbbm.2008.08.002 ↗
9. Lu K, Lu J (2004) Nanostructured surface layer on metallic materials induced by surface mechanical attrition treatment. Mater Sci Eng A 375–377:38–4510.1016/j.msea.2003.10.261 ↗
10. Lu K (2016) Stabilizing nanostructures in metals using grain and twin boundary architectures. Nat Rev Mater 1:1601910.1038/natrevmats.2016.19 ↗
11. Büscher R, Täger G, Dudzinski W, Gleising B, Wimmer MA, Fischer A (2005) Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res Part B 72B:206–21410.1002/jbm.b.30132 ↗
12. Balyanov A, Kutnyakova J, Amirkhanova NA, Stolyarov VV, Valiev RZ, Liao XZ, Zhao YH, Jiang YB et al (2004) Corrosion resistance of ultra fine-grained Ti. Scripta Mater 51:225–22910.1016/j.scriptamat.2004.04.011 ↗
13. ASTM (2011) Standard specification for wrought Cobalt-28Chromium-6Molybdenum alloys for surgical implants (UNS R31537, UNS R31538, and UNS R31539)
14. Lanzutti A, Andreatta F, Rossi L, Benedetto PD, Causero A, Magnan M, Fedrizzi L (2019) Corrosion fatigue failure of a high carbon CoCrMo modular hip prosthesis: failure analysis and electrochemical study. Eng Fail Anal 105:856–86810.1016/j.engfailanal.2019.07.044 ↗
15. Sadiq K, Black RA, Stack MM (2014) Bio-tribocorrosion mechanisms in orthopaedic devices: mapping the micro-abrasion–corrosion behaviour of a simulated CoCrMo hip replacement in calf serum solution. Wear 316:58–6910.1016/j.wear.2014.04.016 ↗
16. Ţălu Ş, Stach S, Mahajan A, Pathak D, Wagner T, Kumar A, Bedi RK (2014) Multifractal analysis of drop-casted copper (II) tetrasulfophthalocyanine film surfaces on the indium tin oxide substrates. Surf Interface Anal 46:393–39810.1002/sia.5492 ↗
17. Zhang X, Li Y, Tang N, Onodera E, Chiba A (2014) Corrosion behaviour of CoCrMo alloys in 2 wt% sulphuric acid solution. Electrochim Acta 125:543–55510.1016/j.electacta.2014.01.143 ↗
18. Chen Y, Li Y, Kurosu S, Yamanaka K, Tang N, Koizumi Y, Chiba A (2014) Effects of sigma phase and carbide on the wear behavior of CoCrMo alloys in Hanks' solution. Wear 310:51–6210.1016/j.wear.2013.12.010 ↗
19. Chiba A, Kumagai K, Nomura N, Miyakawa S (2007) Pin-on-disk wear behavior in a like-on-like configuration in a biological environment of high carbon cast and low carbon forged Co–29Cr–6Mo alloys. Acta Mater 55:1309–131810.1016/j.actamat.2006.10.005 ↗
20. Liu L, Li Y, Wang F (2007) Influence of micro-structure on corrosion behavior of a Ni-based superalloy in 3.5% NaCl. Electrochim Acta 52:7193–720210.1016/j.electacta.2007.05.043 ↗
21. Bidiville A, Favero M, Stadelmann P, Mischler S (2007) Effect of surface chemistry on the mechanical response of metals in sliding tribocorrosion systems. Wear 263:207–21710.1016/j.wear.2007.01.066 ↗
22. Wang ZW, Yan Y, Qiao LJ (2017) Protein adsorption on implant metals with various deformed surfaces. Colloids Surf B Biointerfaces 156:62–7010.1016/j.colsurfb.2017.05.015 ↗
23. Cassar J, Mallia B, Karl A, Buhagiar J (2016) EIS of carburised CoCrMo: evolution of parameters characterising the metal-electrolyte interface. Surf Coat Technol 292:90–9810.1016/j.surfcoat.2016.03.033 ↗
24. Muñoz AI, Mischler S (2007) Interactive effects of albumin and phosphate ions on the corrosion of CoCrMo implant alloy. J Electrochem Soc 154:C562–C57010.1149/1.2764238 ↗
25. Li DG, Chen DR, Liang P (2017) Enhancement of cavitation erosion resistance of 316 L stainless steel by adding molybdenum. Ultrason Sonochem 35:375–38110.1016/j.ultsonch.2016.10.015 ↗
26. Fattah-alhosseini A, Vafaeian S (2015) Comparison of electrochemical behavior between coarse-grained and fine-grained AISI 430 ferritic stainless steel by Mott-Schottky analysis and EIS measurements. J Alloys Compd 639:301–30710.1016/j.jallcom.2015.03.142 ↗
27. Macdonald DD (2011) The history of the point defect model for the passive state: a brief review of film growth aspects. Electrochim Acta 56:1761–177210.1016/j.electacta.2010.11.005 ↗
28. Zavieh AH, Espallargas N (2016) Effect of 4-point bending and normal load on the tribocorrosion-fatigue (multi-degradation) of stainless steels. Tribol Int 99:96–10610.1016/j.triboint.2016.03.016 ↗
29. Wimmer MA, Sprecher C, Hauert R, Täger G, Fischer A (2003) Tribochemical reaction on metal-on-metal hip joint bearings. Wear 255:1007–101410.1016/S0043-1648(03)00127-3 ↗
30. Wang Z, Yan Y, Su Y, Qiao L (2016) Effect of proteins on the surface microstructure evolution of a CoCrMo alloy in bio-tribocorrosion processes. Colloid Surface B 145:176–18410.1016/j.colsurfb.2016.05.002 ↗
31. Sun Y, Bailey R (2018) Effect of sliding conditions on micropitting behaviour of AISI 304 stainless steel in chloride containing solution. Corros Sci 139:197–20510.1016/j.corsci.2018.05.004 ↗
32. Mathew MT, Nagelli C, Pourzal R, Fischer A, Laurent MP, Jacobs JJ, Wimmer MA (2014) Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J Mech Behav Biomed Mater 29:199–21210.1016/j.jmbbm.2013.08.018 ↗
33. Ouerd A, Alemany-Dumont C, Normand B, Szunerits S (2008) Reactivity of CoCrMo alloy in physiological medium: electrochemical characterization of the metal/protein interface. Electrochim Acta 53:4461–446910.1016/j.electacta.2008.01.025 ↗
34. Zhang B, Wang J, Wu B, Guo XW, Wang YJ, Chen D, Zhang YC, Du K et al (2018) Unmasking chloride attack on the passive film of metals. Nat Commun 9:255910.1038/s41467-018-04942-x ↗
35. Wang Z, Yan Y, Qiao L (2015) Tribocorrosion behavior of nanocrystalline metals—a review. Mater Trans 56:1759–176310.2320/matertrans.M2015280 ↗
36. Harandi SE, Banerjee PC, Easton CD, Singh Raman RK (2017) Influence of bovine serum albumin in Hanks' solution on the corrosion and stress corrosion cracking of a magnesium alloy. Mater Sci Eng C Mater Biol Appl 80:335–34510.1016/j.msec.2017.06.002 ↗
37. Kocijan A, Milošev I, Pihlar B (2004) Cobalt-based alloys for orthopaedic applications studied by electrochemical and XPS analysis. J Mater Sci Mater Med 15:643–65010.1023/B:JMSM.0000030204.08616.3d ↗