journal article·2023-03

Impedimetric immunosensor based on chitosan-modified gold wire with Au@rGO nanocomposite for the detection of brain natriuretic peptide (BNP)

Twinkle Dahiya, Ravina, Avantika Mann, Hari Mohan, Minakshi Sharma, C. S. Pundir, J. S. Rana

Journal of Materials Science· Volume 58· Issue 11
Publisher page

Abstract

The brain natriuretic peptide (BNP) is the most common and powerful cardiac biomarker for a range of diseases, especially heart failure (HF). To detect HF at early stage, we have developed an impedimetric immunosensor for measuring BNP levels in serum. The anti-BNP antibodies were immobilized on the surface of Au wire along with chitosan (CHIT), gold nanoparticles (AuNPs) and reduced graphene oxide (rGO) nanocomposite (CHIT-Au@rGO). All structural characterizations of electrode at different stages were performed using transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) and zeta-potential (Z-potential). The charge transfer resistance (Rct) values of working electrode showed linearity with BNP concentrations in the range of 1*10–2–1*103 pg/mL with a LOD score of 0.65 pg/mL and LOQ of 1.99 pg/mL, demonstrating the development of an improved BNP immunosensor, a potent biomarker for HF. The current immunosensor was successful in detection of BNP in spiked human serum samples. Analytic recovery of added BNP in human sera was 101.75%. There was no interference from BSA or IgG in measuring BNP by the present electrode, demonstrating the specificity of present BNP immunosensor.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Advancements in Battery Materials · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Ponikowski P, Anker SD, AlHabib KF et al (2014) Heart failure: preventing disease and death worldwide. ESC Hear Fail 1:4–25. https://doi.org/10.1002/ehf2.1200510.1002/ehf2.12005 ↗
2. Novodchuk I, Kayaharman M, Ausri IR et al (2021) An ultrasensitive heart-failure BNP biosensor using B/N co-doped graphene oxide gel FET. Biosens Bioelectron 180:18. https://doi.org/10.1016/j.bios.2021.11311410.1016/j.bios.2021.113114 ↗
3. Yoshimura M, Yasue H, Morita E et al (1991) Hemodynamic, renal, and hormonal responses to brain natriuretic peptide infusion in patients with congestive heart failure. Circulation 84:1581–1588. https://doi.org/10.1161/01.CIR.84.4.158110.1161/01.CIR.84.4.1581 ↗
4. Dahiya T, Yadav S, Yadav N et al (2021) Monitoring of BNP cardiac biomarker with major emphasis on biosensing methods: a review. Sensors Int 2:18. https://doi.org/10.1016/j.sintl.2021.10010310.1016/j.sintl.2021.100103 ↗
5. Magnussen C, Blankenberg S (2018) Biomarkers for heart failure: small molecules with high clinical relevance. J Intern Med 283:530–543. https://doi.org/10.1111/joim.1275610.1111/joim.12756 ↗
6. Van Kimmenade RRJ, Januzzi JL (2012) Emerging biomarkers in heart failure. Clin Chem 58:127–138. https://doi.org/10.1373/clinchem.2011.16572010.1373/clinchem.2011.165720 ↗
7. Gaggin HK, Januzzi JL (2013) Biomarkers and diagnostics in heart failure. Biochim Biophys Acta Mol Basis Dis 1832:2442–2450. https://doi.org/10.1016/j.bbadis.2012.12.01410.1016/j.bbadis.2012.12.014 ↗
8. Castiglione V, Aimo A, Vergaro G et al (2021) Biomarkers for the diagnosis and management of heart failure. Heart Fail Rev. 19. https://doi.org/10.1007/s10741-021-10105-w10.1007/s10741-021-10105-w ↗
9. Sarangadharan I, Wang SL, Tai TY et al (2018) Risk stratification of heart failure from one drop of blood using hand-held biosensor for BNP detection. Biosens Bioelectron 107:259–265. https://doi.org/10.1016/j.bios.2018.02.03610.1016/j.bios.2018.02.036 ↗
10. Zhao J, Liang D, Gao S et al (2019) Analyte-resolved magnetoplasmonic nanocomposite to enhance SPR signals and dual recognition strategy for detection of BNP in serum samples. Biosens Bioelectron. 19. https://doi.org/10.1016/j.bios.2019.11144010.1016/j.bios.2019.111440 ↗
11. Grabowska I, Sharma N, Vasilescu A et al (2018) Electrochemical aptamer-based biosensors for the detection of cardiac biomarkers. ACS Omega 3:12010–12018. https://doi.org/10.1021/acsomega.8b0155810.1021/acsomega.8b01558 ↗
12. He X, Yuan R, Chai Y, Shi Y (2008) A sensitive amperometric immunosensor for carcinoembryonic antigen detection with porous nanogold film and nano-Au/chitosan composite as immobilization matrix. J Biochem Biophys Methods 70:823–829. https://doi.org/10.1016/j.jbbm.2007.06.00210.1016/j.jbbm.2007.06.002 ↗
13. He L-H, Xue R, Yang D-B, Liu Y, Song R (2009) Effects of blending chitosan with peg on surface morphology, crystallization and thermal properties. Chin J Polym Sci 27(04):19. https://doi.org/10.1142/S025676790900417510.1142/S0256767909004175 ↗
14. Batra B, Lata S, Sunny et al (2013) Construction of an amperometric bilirubin biosensor based on covalent immobilization of bilirubin oxidase onto zirconia coated silica nanoparticles/chitosan hybrid film. Biosens Bioelectron 44:64–69. https://doi.org/10.1016/j.bios.2012.12.03410.1016/j.bios.2012.12.034 ↗
15. Dinani HS, Pourmadadi M, Yazdian F et al (2022) Fabrication of Au/Fe3O4/RGO based aptasensor for measurement of miRNA-128, a biomarker for acute lymphoblastic leukemia (ALL). Eng Life Sci 22:519–534. https://doi.org/10.1002/elsc.20210017010.1002/elsc.202100170 ↗
16. Akbarzadeh S, Khajehsharifi H, Hajihosseini S (2022) Detection of oxytetracycline using an electrochemical label-free aptamer-based biosensor. Biosensors 12:1–15. https://doi.org/10.3390/bios1207046810.3390/bios12070468 ↗
17. Wu Y, Zheng J, Li Z et al (2009) A novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode. Biosens Bioelectron 24:1389–1393. https://doi.org/10.1016/j.bios.2008.07.07510.1016/j.bios.2008.07.075 ↗
18. Taniselass S, Arshad MKM, Gopinath SCB et al (2021) Impedimetric cardiac biomarker determination in serum mediated by epoxy and hydroxyl of reduced graphene oxide on gold array microelectrodes. Microchim Acta 188:1–13. https://doi.org/10.1007/s00604-021-04922-x10.1007/s00604-021-04922-x ↗
19. Deswal R, Narwal V, Dang AS, Pundir CS (2019) An ultrasensitive electrochemical immunosensor for detection of sex hormone binding globulin. Microchem J 149:20. https://doi.org/10.1016/j.microc.2019.10401010.1016/j.microc.2019.104010 ↗
20. Serafín V, Torrente-Rodríguez RM, González-Cortés A et al (2018) An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry. Talanta 179:131–138. https://doi.org/10.1016/j.talanta.2017.10.06310.1016/j.talanta.2017.10.063 ↗
21. Zhang Y, Zhang K, Ma H (2009) Electrochemical DNA biosensors based on gold nanoparticles/cysteamine/poly(glutamic acid) modified electrode. Am J Biomed Sci. 20. https://doi.org/10.5099/aj09020011510.5099/aj090200115 ↗
22. Maddinedi SB, Mandal BK, Vankayala R et al (2014) Casein mediated green synthesis and decoration of reduced graphene oxide. Spectrochim Acta Part A Mol Biomol Spectrosc 126:227–231. https://doi.org/10.1016/j.saa.2014.01.11410.1016/j.saa.2014.01.114 ↗
23. Habte AT, Ayele DW, Hu M (2019) Synthesis and characterization of reduced graphene oxide (rGO) started from graphene oxide (GO) using the tour method with different parameters. Adv Mater Sci Eng. 20. https://doi.org/10.1155/2019/505816310.1155/2019/5058163 ↗
24. Movahed SK, Fakharian M, Dabiri M, Bazgir A (2014) Gold nanoparticle decorated reduced graphene oxide sheets with high catalytic activity for Ullmann homocoupling. RSC Adv 4:5243–5247. https://doi.org/10.1039/c3ra45518a10.1039/c3ra45518a ↗
25. Dong X, Huang W, Chen P (2011) In situ synthesis of reduced graphene oxide and gold nanocomposites for nanoelectronics and biosensing. Nanoscale Res Lett 6:1–6. https://doi.org/10.1007/s11671-010-9806-810.1007/s11671-010-9806-8 ↗
26. Mindivan (2016) The synthesis and charecterization of graphene oxide (Go) and reduced graphene oxide (Rgo). Int Sci J 35:51–54
27. Saeidi Tabar F, Pourmadadi M, Yazdian F, Rashedi H (2021) Design of a novel electrochemical nanobiosensor for the detection of prostate cancer by measurement of PSA using graphene-based materials. AUT J Electr Eng 53:21. https://doi.org/10.22060/eej.2021.19463.539610.22060/eej.2021.19463.5396 ↗
28. Wu L, Lu X, Fu X et al (2017) Gold nanoparticles dotted reduction graphene oxide nanocomposite based electrochemical aptasensor for selective, rapid, sensitive and congener-specific PCB77 detection. Sci Rep 7:1–7. https://doi.org/10.1038/s41598-017-05352-710.1038/s41598-017-05352-7 ↗
29. Wang L, Han Y, Wang H et al (2021) A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I. J Semicond. 21. https://doi.org/10.1088/1674-4926/42/9/09260110.1088/1674-4926/42/9/092601 ↗
30. Batra B, Lata S, Sharma M, Pundir CS (2013) An acrylamide biosensor based on immobilization of hemoglobin onto multiwalled carbon nanotube/copper nanoparticles/polyaniline hybrid film. Anal Biochem 433:210–217. https://doi.org/10.1016/j.ab.2012.10.02610.1016/j.ab.2012.10.026 ↗
31. Batra B, Lata S, Pundir CS (2013) Construction of an improved amperometric acrylamide biosensor based on hemoglobin immobilized onto carboxylated multi-walled carbon nanotubes/iron oxide nanoparticles/chitosan composite film. Bioprocess Biosyst Eng 36:1591–1599. https://doi.org/10.1007/s00449-013-0931-510.1007/s00449-013-0931-5 ↗
32. Chen X, Wang Y, Zhou J et al (2008) Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film. Anal Chem 80:2133–2140. https://doi.org/10.1021/ac702137610.1021/ac7021376 ↗
33. Uygun ZO, Ertuǧrul Uygun HD (2014) A short footnote: circuit design for faradaic impedimetric sensors and biosensors. Sens Actuators B Chem 202:448–453. https://doi.org/10.1016/j.snb.2014.05.02910.1016/j.snb.2014.05.029 ↗
34. Wang H, Ma Z, Han H (2019) A novel impedance enhancer for amperometric biosensor based ultrasensitive detection of matrix metalloproteinase-2. Bioelectrochemistry 130:22. https://doi.org/10.1016/j.bioelechem.2019.06.00910.1016/j.bioelechem.2019.06.009 ↗
35. Deepa NB, Chaudhary R, Pundir CS (2022) Amperometric detection of tumor suppressor protein p53 via pencil graphite electrode for fast cancer diagnosis: p53 targeted immunosensor for early diagnosis of cancer. Anal Biochem 639:22. https://doi.org/10.1016/j.ab.2021.11452810.1016/j.ab.2021.114528 ↗
36. Vasantham S, Alhans R, Singhal C et al (2020) Paper based point of care immunosensor for the impedimetric detection of cardiac troponin I biomarker. Biomed Microdevices. 22. https://doi.org/10.1007/s10544-019-0463-010.1007/s10544-019-0463-0 ↗