Photoluminescence investigations on alumina ceramic bearing couples tested under different angles of inclination in a Hip joint simulator
Source abstract
Abstract
Aseptic loosening due to wear and dislocation of the implant represents the main complication after total hip arthroplasty. To gain more insight into the influence of the implant position on wear, commercial alumina couplings have been tested in a hip joint simulator under three different angles of cup inclination (23°, 45°, 63°) with respect to a horizontal plane. The planned length of the test was ten million cycles. However, the test was stopped at 5.5 million cycles due to the fracture of one of the femoral heads, tested with at angle of 63°. The residual stress state in the worn acetabular cups and in the fractured femoral head were evaluated by the frequency shift and broadening of the R1 and R2 fluorescence bands due to the Cr3+ ions naturally present in alumina ceramics as trace impurities.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (77)
Show source-provided references
1. M. JASTY, W. JIRANEK and W. H. HARRIS, Clin. Orthop. Rel. Res. 285 (1992) 116.10.1097/00003086-199212000-00016 ↗
2. S. R. GOLDRING, C. R. CLARK and T. M. WRIGHT, J. Bone Joint Surg. Am. 75 (1993) 799.10.2106/00004623-199306000-00001 ↗
3. T. A. GRUEN, G. M. MCNEICE and H. C. AMSTUTZ, Clin. Orthop. Rel. Res. 141 (1979) 17.
4. W. H. HARRIS, A. L. SCHILLER, J. M. SCHOLLER, R. A. FREIBERG and R. SCOTT, J. Bone Joint Surg. Am. 58 (1976) 612.10.2106/00004623-197658050-00005 ↗
5. J. K. J. MAGUIRE, M. F. COSCIA and M. H. LYNCH, Clin. Orthop. Rel. Res. 216 (1987) 213.
6. W. J. MALONEY and R. L. SMITH, Instr. Course Lect. 45 (1996) 171.
7. S. SANTAVIRTA, Y. T. KONTTINEN, V. BERGROTH, A. ESKOLA, K. TALLROTH and T. S. LINDHOLM, J. Bone Joint Surg. Am. 72 (1990) 252.10.2106/00004623-199072020-00014 ↗
8. G. WILLMANN, Orthopedics21 (1998) 173.10.3928/0147-7447-19980201-11 ↗
9. R. M. ROSE, H. J. NUSBAUM, H. SCHNEIDER, M. RIES, I. PAUL, A. CRUGNOLA, S. R. SIMON and E. L. RADIN, J. Bone Joint Surg. Am. 62 (1980) 537.10.2106/00004623-198062040-00007 ↗
10. J. M. CUCKLER, J. BEARCROFT and C. M. ASGIAN, Clin. Orthop. Rel. Res. 317 (1995) 57.
11. A. TONI, S. TERZI, A. SUDANESE, M. TABARRONI, F. A. ZAPPOLI, S. STEA and A. GIUNTI, Chir. Organi Mov. 80 (1995) 13.
12. F. MACCHI and G. WILLMAN, Lo scalpello15 (2001) 99.
13. H. L. COSTA, V. C. PANDOLFELLI and J. D. BIASOLI DE MELLO, Wear203-204 (1997) 626.10.1016/S0043-1648(97)07449-8 ↗
14. S. AFFATATO, M. TESTONI, G. L. CACCIARI and A. TONI, Biomaterials20 (1999) 971.10.1016/S0142-9612(98)00253-1 ↗
15. H. OONISHI, H. AMINO, M. UENO and H. YUNOKI, in Reliability and Long-Term Results of Ceramics in Orthopaedics. 4th International CeramTec Symposium, Germany, edited by L. Sedel and G. Willmann, (999) p. 7.
16. S. K. TAYLOR, in Reliability and Long-Term Results of Ceramics in Orthopaedics. 4th International CeramTec Symposium, Germany, edited by L. Sedel and G. Willmann, (1999) p. 85.
17. J. FISHER, P. J. FIRKINS, J. TIPPER, E. INGHAM, M. H. STONE and R. FARRAR, in Bioceramic in joint arthroplasty. Proceedings 6th International Biolox Symposium, Germany, edited by A. Toni and G. Willmann, (2001) p. 94.
18. M. J. LAITH, L. J. WILLIAM, Arthroplasty Arthroscopic Surgery10 (1999) 1.
19. F. J. KUMMER, S. A. STUCHIN and V. H. FRANKEL, J. Arthroplasty5 (1990) 28.10.1016/S0883-5403(06)80006-9 ↗
20. R. BADER and G. WILLMANN, Biomed. Tech. (Berl)44 (1999) 212.10.1515/bmte.1999.44.7-8.212 ↗
21. I. BOS and G. WILLMANN, Acta Orthop. Scand. 72 (2001) 335.10.1080/000164701753541970 ↗
22. J. L. TIPPER, A. HATTON, J. E. NEVELOS, E. INGHAM, C. DOYLE, R. STREICHERD, A. B. NEVELOS and J. FISHER, Biomaterials, in press.
23. P. BOUTIN, P. CHRISTEL, J. M. DORLOT, A. MEUNIER, A. DE ROQUANCOURT, D. BLANQUAERT, S. HERMAN, L. SEDEL and J. WITVOET, J. Biomed. Mater. Res. 22 (1998) 1203.10.1002/jbm.820221210 ↗
24. J. M. DORLOT, Clin. Orthop. Rel. Res. 282 (1992) 47.10.1097/00003086-199209000-00006 ↗
25. J. M. DORLOT, P. CHRISTEL and A. MEUNIER, J. Biomed. Mater. Res. 23 (1989) 299.10.1002/jbm.820231405 ↗
26. H. SKINNER, in “Reconstructive Surgery of the Joints” (Churchill Livingstone, New York, 1991), p. 53.
27. A. STEVEN, M. D. PATERNO, P. F. LACHIEWICZ and S. S. KELLEY, J. Bone Joint Surg. Am. 79 (1997) 1202.10.2106/00004623-199708000-00013 ↗
28. B. F. MORREY, Clin. Orthop. Rel. Res. 344 (1997) 179.10.1097/00003086-199711000-00019 ↗
29. G. E. LEWINNEK, J. L. LEWIS, R. TARR, C. L. COMPERE and J. R. ZIMMERMAN, J. Bone Joint Surg. Am. 60 (1978) 217.10.2106/00004623-197860020-00014 ↗
30. M. NOGLER, O. KESSLER, A. PRASSL, B. DONNELLY, R. STREICHER, J. B. SLEDGE and M. KRISMER, Clin. Orthop. Rel. Res. 426 (2004) 159.10.1097/01.blo.0000141902.30946.6d ↗
31. M. M. MAK and Z. M. JIN, Key Eng. Mater. 254–256 (2004) 639.
32. R. J. BADER, E. STEINHAUSER, G. WILLMAN and R. GRADINGER, ibid. 192-195 (2001) 549.10.4028/www.scientific.net/KEM.192-195.549 ↗
33. H. MITTELMEIER and J. HEISEL, Clin. Orthop. Rel. Res. 282 (1992) 64.10.1097/00003086-199209000-00008 ↗
34. H. J. REFIOR, W. PLITZ and A. WALTER, Bioceramics10 (1997) 127.
35. E. NEVELOS, E. INGHAM, C. DOYLE, J. FISHER and A. B. NEVELOS, Biomaterials20 (1999) 1833.10.1016/S0142-9612(99)00081-2 ↗
36. A. NEVELOS, P. A. EVANS, P. HARRISON and M. RAINFORTH, Proc. Inst. Mech. Eng. (Part H)207 (1993) 155.10.1243/PIME_PROC_1993_207_288_02 ↗
37. E. A. MAGNISSALIS, T. A. XENAKIS and C. ZACHARIS, J. Biomed. Mater. Res. (Appl. Biomater.)58 (2001) 593.10.1002/jbm.1057 ↗
38. F. PRUDHOMMEAUX, M. HAMADOUCHE, J. NEVELOS, C. DOYLE, A. MEUNIER and L. SEDEL, Clin. Orthop. Rel. Res. 379 (2000) 113.10.1097/00003086-200010000-00014 ↗
39. W. L. WALTER, G. M. INSLEY, W. K. WALTER and M. A. TUKE, J. Arthroplasty19 (2004) 402.10.1016/j.arth.2003.09.018 ↗
40. R. J. BADER, E. STEINHAUSER, G. WILLMANN and R. GRADINGER, Hip International11 (2001) 80.10.1177/112070000101100203 ↗
41. J. E. NEVELOS, E. INGHAM, C. DOYLE, A. B. NEVELOS and J. FISHER, J. Mater. Sci.: Mater. Med. 12 (2001) 141.
42. L. GRABNER, J. Appl. Phys. 49 (1978) 580.10.1063/1.324682 ↗
43. R. KRISHNAN, R. KESAVAMOORTHY, S. DASH, A. K. TYAGI and B. RAJ, Scripta Mater. 48 (2003) 1099.10.1016/S1359-6462(02)00631-0 ↗
44. M. A. GARCIA, S. E. PAJE and J. LLOPIS, Mater. Sci. Eng. A325 (2002) 302.10.1016/S0921-5093(01)01461-7 ↗
45. Q. MA and D. R. CLARKE, J. Am. Ceram. Soc. 77 (1994) 298.10.1111/j.1151-2916.1994.tb06996.x ↗
46. E. MERLANI, C. SCHMID and V. SERGO, ibid. 84 (2001) 2962.10.1111/j.1151-2916.2001.tb01121.x ↗
47. Q. MA and D. R. CLARKE, ibid. 76 (1993) 1433.10.1111/j.1151-2916.1993.tb03922.x ↗
48. J. HUE and D. R. CLARKE, ibid. 78 (1995) 1347.10.1111/j.1151-2916.1995.tb08493.x ↗
49. V. SERGO, G. PEZZOTTI, O. SBAIZERO and T. NISHIDA, Acta Mater. 46 (1998) 1701.10.1016/S1359-6454(97)00348-0 ↗
50. A. SELCUK and A. ATKINSON, Mater. Sci. Eng. A335 (2002) 147.10.1016/S0921-5093(01)01911-6 ↗
51. R. JANKOWIAK, K. ROBERTS, P. TOMASIK, M. SIKORA, G. J. SMALL and C. H. SCHILLING, ibid. A281 (2000) 45.10.1016/S0921-5093(99)00749-2 ↗
52. G. BERGMANN, F. GRAICHEN and A. ROHLMANN, J. Biomechanics28 (1995) 535.10.1016/0021-9290(94)00105-D ↗
53. Idem., ibid. 26 (1993) 969.10.1016/0021-9290(93)90058-M ↗
54. G. BERGMANN, G. DEURETZBACHER, M. HELLER, F. GRAICHEN, A. ROHLMANN, J. STRAUSS and G. N. DUDA, J. Biomech. 34 (2001) 859.10.1016/S0021-9290(01)00040-9 ↗
55. V. SAIKKO and O. CALONIUS, ibid. 35 (2002) 455.10.1016/S0021-9290(01)00224-X ↗
56. C. KADDICK and M. A. WIMMER, Proc. Inst. Mech. Eng. Part H215 (2001) 429.10.1243/0954411011536019 ↗
57. S. AFFATATO, G. BERSAGLIA, I. FOLTRAN, D. EMILIANI, F. TRAINA and A. TONI, Wear256 (2004) 400.10.1016/S0043-1648(03)00455-1 ↗
58. P. BOUTIN and D. BLANQUAERT, Rev. Chir. Orthop. Reparatrice Appar. Mot. 67 (1981) 279.
59. W. PLITZ and P. GRISS, in “Implant Retrieval: Material and Histological Analysis”, Vol. 601, edited by A. Weinstein, D. Gibbons, S. Brown and W. Ruff (National Bureau of Standards Specific Publication United States Department of Commerce, Washington DC, 1981) p. 131.
60. L. SEDEL, Clin. Orthop. Rel. Res. 379 (2000) 48.10.1097/00003086-200010000-00008 ↗
61. R. S. NIZARD, L. SEDEL, P. CHRISTEL, A. MEUNIER, M. SOUDRY and J. WITVOET, ibid. 282 (1992) 53.10.1097/00003086-199209000-00007 ↗
62. D. I. BARDOS, in “Clinical Experience with High Performance Total Hip Replacement. Ceramics in clinical application” (Elsevier, Amsterdam, 1987).
63. T. SHISHIDO, I. C. CLARKE, P. WILLIAMS, M. BOEHLER, T. ASANO, M. SHOJI, T. MASAOKA, K. YAMAMOTO and A. IMAKIIRE, J. Biomed. Mater. Res. (Appl. Biomater.)67 (2003) 638.10.1002/jbm.b.10048 ↗
64. J. NEVELOS, E. INGHAM, C. DOYLE, R. STREICHER, A. NEVELOS and W. WALTER, J. Arthropl. 15 (2000) 793.10.1054/arth.2000.8100 ↗
65. G. MACCAURO, C. PICONI, L. PROIETTI, M. TIMPANARO, V. DE SANTIS, G. MAGLIOCCHETTI and E. DE SANTIS, Hip Int. 11 (2001) 201.10.1177/112070000101100404 ↗
66. J. BONO, L. SANFORD and J. TOUSSAINT, J. Arthroplasty9 (1994) 119.10.1016/0883-5403(94)90059-0 ↗
67. J. G. KENNEDY, W. B. ROGERS, K. E. SOFFE, R. J. SULLIVAN, D. G. GRIFFEN and L. J. SHEEHAN, ibid. 12 (1998) 530.10.1016/S0883-5403(98)90052-3 ↗
68. R. KLABUNDE and D. PORTMANN, in 12th Conference of the European Society of Biomechanics 2000.
69. J. E. NEVELOS, E. INGHAM, C. DOYLE, A. B. NEVELOS and J. FISHER, Biomaterials22 (2001) 2191.10.1016/S0142-9612(00)00361-6 ↗
70. J. ALLAIN, F. ROUDOT-THORAVAL, J. DELECRIN, P. ANRACT, H. MIGAUD and D. GOUTALLIER, J. Bone Joint Surg. Am. 85 (2003) 825.10.2106/00004623-200305000-00009 ↗
71. G. WILLMANN, Clin. Orthop. Rel. Res. 379 (2000) 22.10.1097/00003086-200010000-00004 ↗
72. M. ORTIZ and S. SURESH, J. Appl. Mech. 60 (1993) 77.10.1115/1.2900782 ↗
73. A. ANDRISANO, E. DRAGONI and A. STROZZI, Proc. Inst. Mech. Eng. Part H204 (1990) 157.10.1243/PIME_PROC_1990_204_250_02 ↗
74. ASTM/F-1636 1995 Standard Specification for Bores and Cones for Modular Femoral Heads. ASTM.
75. A. ZIEBIG and H. LUBER, in “Ceramic in Surgery”, edited by P. Vincenzini (Elsevier, Amsterdam, 1983) p. 267.
76. P. DALLA PRIA, in “The Ceramic-Ceramic Coupling in Hip Prosthesis” (LIMA-Lto S.p.A., Udine, 1997) p. 56.
77. R. A. WORDSWORTH and B. WEIGHTMAN, Biomaterials7 (1986) 83.10.1016/0142-9612(86)90061-X ↗