journal article·2019-05

Improved in vitro bioactivity and electrochemical behavior of hydroxyapatite-coated NiTi shape memory alloy

Tahir Sattar, Tareq Manzoor, Fazal Ahmad Khalid, Muhammad Akmal, Ghuzanfar Saeed

Journal of Materials Science· Volume 54· Issue 9
Publisher page

Abstract

Nickel titanium (NiTi) shape memory alloys have a vigorous prospective for biomedical solicitations. In this work, electrochemical behavior of hydroxyapatite (HA) coated and thermally oxidized near equiatomic NiTi shape memory alloys was efficaciously investigated for biomedical applications. NiTi samples were spin-coated with laboratory-synthesized HA followed by drying and calcination at 120 ± 5 °C and 450 ± 5 °C, respectively. Similarly, uncoated NiTi samples were thermally oxidized by heating at 450 ± 5 °C in air. The comparison was made among HA-coated, thermally oxidized and uncoated samples. Scanning electron microscope (SEM), atomic force microscope and X-ray diffraction confirm the presence of Titania and HA coating on the NiTi substrates. Electrochemical testing results showed the better resistance against corrosion for the HA-coated samples because of the protective coatings of HA and Titania, as compared to the rest. Moreover, Fourier transform infrared spectroscopy and SEM reveal that the HA-coated sample will provide bioactive cushion to the host structure for better adhesion during the implanted period, while the implant will do its job.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Katić J, Metikoš-Huković M, Babić R, Marciuš M (2013) Sol–gel derived biphasic calcium phosphate ceramics on nitinol. Int J Electrochem Sci 8:1394–140810.1016/S1452-3981(23)14106-X ↗
2. Qiu D, Wang A, Yin Y (2010) Characterization and corrosion behavior of hydroxyapatite/zirconia composite coating on NiTi fabricated by electrochemical deposition. Appl Surf Sci 257:1774–1778. https://doi.org/10.1016/j.apsusc.2010.09.01410.1016/j.apsusc.2010.09.014 ↗
3. Kanetaka H, Shimizu Y, Hosoda H, Tomizuka R, Suzuki A, Miyazaki S et al (2005) Orthodontic tooth movement in rats using Ni-free Ti-base SMA wire. Int Congr Ser 1284:310–311. https://doi.org/10.1016/j.ics.2005.06.01310.1016/j.ics.2005.06.013 ↗
4. Zhao Y, Jiang C, Xu Z, Cai F, Zhang Z, Fu P (2015) Microstructure and corrosion behavior of Ti nanoparticles reinforced Ni–Ti composite coatings by electrodeposition. Mater Des 85:39–46. https://doi.org/10.1016/j.matdes.2015.06.14410.1016/j.matdes.2015.06.144 ↗
5. Akmal M, Raza A, Khan MM, Khan MI, Hussain MA (2016) Effect of nano-hydroxyapatite reinforcement in mechanically alloyed NiTi composites for biomedical implant. Mater Sci Eng, C 68:30–36. https://doi.org/10.1016/j.msec.2016.05.09210.1016/j.msec.2016.05.092 ↗
6. Maleki-Ghaleh H, Khalili V, Khalil-Allafi J, Javidi M (2012) Hydroxyapatite coating on NiTi shape memory alloy by electrophoretic deposition process. Surf Coat Technol 208:57–63. https://doi.org/10.1016/j.surfcoat.2012.08.00110.1016/j.surfcoat.2012.08.001 ↗
7. Qiu D, Yang L, Yin Y, Wang A (2011) Preparation and characterization of hydroxyapatite/titania composite coating on NiTi alloy by electrochemical deposition. Surf Coat Technol 205:3280–3284. https://doi.org/10.1016/j.surfcoat.2010.11.04910.1016/j.surfcoat.2010.11.049 ↗
8. Yeung KWK, Poon RWY, Liu XY, Ho JPY, Chung CY, Chu PK et al (2005) Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel–titanium shape memory alloys. J Biomed Mater Res, Part A 75A:256–267. https://doi.org/10.1002/jbm.a.3041310.1002/jbm.a.30413 ↗
9. Petrini L, Migliavacca F (2011) Biomedical applications of shape memory alloys. J Metall 2011:1–15. https://doi.org/10.1155/2011/50148310.1155/2011/501483 ↗
10. Karakaş A, Hazar Yoruç AB, Ceylan Erdoğan D, Doğan M (2012) Effect of different calcium precursors on biomimetic hydroxyapatite powder properties. Acta Phys Pol, A 121:236–23910.12693/APhysPolA.121.236 ↗
11. Akmal M, Hussain MA, Ikram H, Sattar T, Jameel S, Kim JY et al (2016) In vitro electrochemical and bioactivity evaluation of SS316L reinforced hydroxyapatite functionally graded materials fabricated for biomedical implants. Ceram Int 42:3855–3863. https://doi.org/10.1016/j.ceramint.2015.11.05010.1016/j.ceramint.2015.11.050 ↗
12. Liu D-M, Yang Q, Troczynski T (2002) Sol–gel hydroxyapatite coatings on stainless steel substrates. Biomaterials 23:691–698. https://doi.org/10.1016/S0142-9612(01)00157-010.1016/S0142-9612(01)00157-0 ↗
13. Jang Y, Tan Z, Jurey C, Xu Z, Dong Z, Collins B et al (2015) Understanding corrosion behavior of Mg–Zn–Ca alloys from subcutaneous mouse model: effect of Zn element concentration and plasma electrolytic oxidation. Mater Sci Eng, C 48:28–40. https://doi.org/10.1016/j.msec.2014.11.02910.1016/j.msec.2014.11.029 ↗
14. Ahmad Z (2006) Corrosion kinetics. In: Principles of corrosion engineering and corrosion control. Elsevier, pp 57–119. https://doi.org/10.1016/b978-075065924-6/50004-010.1016/b978-075065924-6/50004-0 ↗
15. Kokubo T, Takadama H (2006) How useful is SBF in predicting in vivo bone bioactivity? Biomaterials 27:2907–2915. https://doi.org/10.1016/j.biomaterials.2006.01.01710.1016/j.biomaterials.2006.01.017 ↗
16. Maleki-Ghaleh H, Khalil-Allafi J, Khalili V, Shakeri MS, Javidi M (2014) Effect of hydroxyapatite coating fabricated by electrophoretic deposition method on corrosion behavior and nickel release of NiTi shape memory alloy. Mater Corros 65:725–732. https://doi.org/10.1002/maco.20120695010.1002/maco.201206950 ↗
17. Chembath M, Balaraju JN, Sujata M (2015) Surface characteristics, corrosion and bioactivity of chemically treated biomedical grade NiTi alloy. Mater Sci Eng, C 56:417–425. https://doi.org/10.1016/j.msec.2015.06.05110.1016/j.msec.2015.06.051 ↗
18. Milošev I, Kosec T (2007) Metal ion release and surface composition of the Cu–18Ni–20Zn nickel–silver during 30 days immersion in artificial sweat. Appl Surf Sci 254:644–652. https://doi.org/10.1016/j.apsusc.2007.06.04910.1016/j.apsusc.2007.06.049 ↗
19. Sanosh KP, Chu M-C, Balakrishnan A, Kim TN, Cho S-J (2009) Preparation and characterization of nano-hydroxyapatite powder using sol–gel technique. Bull Mater Sci 32:465–470. https://doi.org/10.1007/s12034-009-0069-x10.1007/s12034-009-0069-x ↗
20. Venkateswarlu K, Rameshbabu N, Bose AC, Muthupandi V, Subramanian S, MubarakAli D et al (2012) Fabrication of corrosion resistant, bioactive and antibacterial silver substituted hydroxyapatite/titania composite coating on Cp Ti. Ceram Int 38:731–740. https://doi.org/10.1016/j.ceramint.2011.07.06510.1016/j.ceramint.2011.07.065 ↗
21. Chen MF, Yang XJ, Hu RX, Cui ZD, Man HC (2004) Bioactive NiTi shape memory alloy used as bone bonding implants. Mater Sci Eng, C 24:497–502. https://doi.org/10.1016/j.msec.2003.11.00110.1016/j.msec.2003.11.001 ↗
22. Surmenev RA (2012) A review of plasma-assisted methods for calcium phosphate-based coatings fabrication. Surf Coat Technol 206:2035–2056. https://doi.org/10.1016/j.surfcoat.2011.11.00210.1016/j.surfcoat.2011.11.002 ↗
23. Zhou H, Lee J (2011) Nanoscale hydroxyapatite particles for bone tissue engineering. Acta Biomater 7:2769–2781. https://doi.org/10.1016/j.actbio.2011.03.01910.1016/j.actbio.2011.03.019 ↗